Abstract

Lenovo ThinkSystem SR630 is an ideal 2-socket 1U rack server for small businesses up to large enterprises that need industry-leading reliability, management, and security, as well as maximizing performance and flexibility for future growth. The SR630 server is designed to handle a wide range of workloads, such as databases, virtualization and cloud computing, virtual desktop infrastructure (VDI), infrastructure security, systems management, enterprise applications, collaboration/email, streaming media, web, and HPC.

This product guide provides essential technical and pre-sales information on the SR630 server, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR630 server and consider its use in IT solutions.

Looking for SR630 V2? See the product guide for the Lenovo ThinkSystem SR630 V2 Server, https://lenovopress.com/lp1391-thinksystem-sr630-v2-server

Change History

Changes in the March 6, 2024:

  • The following preconfigured models for customers in EMEA are withdrawn from marketing:
    • 7X02A0HLEA, 7X02A0GXEA, 7X02A0HFEA, 7X02A0HQEA, 7X02A0JREA, 7X02A0JVEA, 7X02A0JXEA, 7X02A0K0EA, 7X02A0GQEA, 7X02A0GWEA, 7X02A0HEEA, 7X02A0HPEA, 7X02A0JSEA, 7X02A0JYEA, 7X02A0JZEA, 7X02A0H7EA, 7X02A0HCEA, 7X02A0JTEA, 7X02A0H6EA, 7X02A0HBEA, 7X02A0H4EA, 7X02A0HAEA, 7X02A0JWEA, 7X02A0H2EA, 7X02A0H5EA, 7X02A0JUEA, 7X02A0H0EA, 7X02A0H3EA

Walkthrough Video with David Watts and Russ Resnick

Introduction

Lenovo ThinkSystem SR630 is an ideal 2-socket 1U rack server for small businesses up to large enterprises that need industry-leading reliability, management, and security, as well as maximizing performance and flexibility for future growth. The SR630 server is designed to handle a wide range of workloads, such as databases, virtualization and cloud computing, virtual desktop infrastructure (VDI), infrastructure security, systems management, enterprise applications, collaboration/email, streaming media, web, and HPC.

Featuring the second generation of the Intel Xeon Processor Scalable Family (Xeon SP Gen 2), the SR630 server offers scalable performance and storage capacity. The SR630 server supports up to two processors, up to 3 TB of memory capacity with TruDDR4 DIMMs or up to 7.5 TB of memory capacity with a combination of TruDDR4 DIMMs and Intel DC persistent memory modules (DCPMMs), up to 12x 2.5-inch or 4x 3.5-inch drive bays with an extensive choice of NVMe PCIe SSDs, SAS/SATA SSDs, and SAS/SATA HDDs, and flexible I/O expansion options with a LOM slot, a dedicated storage controller slot, and up to 3x PCIe slots.

The following figure shows the Lenovo ThinkSystem SR630 with 2.5-inch hot-swap drives.

Lenovo ThinkSystem SR630
Figure 1 Lenovo ThinkSystem SR630 with 2.5-inch drive bays

Did you know?

The SR630 server features a unique AnyBay design that allows a choice of drive interface types in the same drive bay: SAS drives, SATA drives, or U.2 NVMe PCIe drives.

The SR630 server offers onboard NVMe PCIe ports that allow direct connections to the U.2 NVMe PCIe SSDs, which frees up I/O slots and helps lower NVMe solution acquisition costs.

The SR630 server delivers outstanding memory performance with Performance+ 2933 MHz DIMMs, which is achieved by supporting two-DIMMs-per-channel configurations at speeds up to 10% faster than the Intel specification defines, while still maintaining world-class reliability.

Key features

Combining performance and flexibility, the SR630 server is a great choice for small and medium businesses up to the large enterprise. It can provide outstanding uptime to keep business-critical applications and cloud deployments running safely. Ease of use and comprehensive systems management tools help make deployment easier. Outstanding reliability, availability, and serviceability (RAS) and high-efficiency design improve your business environment and help save operational costs.

Scalability and performance

The SR630 server offers numerous features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with the second generation of the Intel Xeon Processor Scalable Family with up to 28-core processors, up to 38.5 MB of last level cache (LLC), up to 2933 MHz memory speeds, and up to 10.4 GT/s Ultra Path Interconnect (UPI) links.
    • Support for up to two processors, 56 cores, and 112 threads allows to maximize the concurrent execution of multithreaded applications.
    • Intelligent and adaptive system performance with energy efficient Intel Turbo Boost 2.0 Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
    • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
    • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads.
    • Intel Speed Select Technology provides improvements in server utilization and guaranteed per-core performance service levels with more granular control over processor performance.
    • Intel Deep Learning Boost (Vector Neural Network Instruction set [VNNI]) is designed to deliver significant, more efficient Deep Learning (Inference) acceleration for high-performance Artificial Intelligence (AI) workloads.
    • Intel Advanced Vector Extensions 512 (AVX-512) enable acceleration of enterprise-class and high performance computing (HPC) workloads.
  • Helps maximize system performance for data intensive applications with up to 2933 MHz memory speeds and up to 3 TB of memory capacity with 3DS RDIMMs.
  • Boosts the performance of data-intensive applications and delivers consistent service levels at scale for virtualized and cloud environments by using the innovative persistent memory technology that provides a unique combination of affordable large memory capacity and non-volatility for up to 7.5 TB of total server memory capacity, including 3DS RDIMMs and DCPMMs (DC persistent memory modules).
  • Offers flexible and scalable internal storage in a 1U rack form factor with up to 12x 2.5-inch drives for performance-optimized configurations or up to 4x 3.5-inch drives for capacity-optimized configurations, providing a wide selection of SAS/SATA HDD/SSD and PCIe NVMe SSD types and capacities.
  • Provides flexibility to use SAS, SATA, or NVMe PCIe drives in the same drive bays with a unique AnyBay design.
  • Provides I/O scalability with the LOM slot, PCIe 3.0 slot for an internal storage controller, and up to three PCI Express (PCIe) 3.0 I/O expansion slots in a 1U rack form factor.
  • Reduces I/O latency and increases overall system performance with Intel Integrated I/O Technology that embeds the PCI Express 3.0 controller into the Intel Xeon Processor Scalable Family.

Availability and serviceability

The SR630 server provides many features to simplify serviceability and increase system uptime:

  • Designed to run 24 hours a day, 7 days a week
  • Offers protection in the event of a non-correctable memory failure with Single Device Data Correction (SDDC, also known as Chipkill, requires x4-based DIMMs), Adaptive Double Device Data Correction (ADDDC, also known as Redundant Bit Steering [RBS], requires x4-based DIMMs and Intel Xeon Gold or Platinum processors), memory mirroring, and memory rank sparing.
  • Provides easy access to upgrades and serviceable parts (such as processors, memory DIMMs, and adapter cards) with tool-less cover removal.
  • Offers data protection and greater system uptime with hot-swap drives supporting basic or advanced RAID redundancy.
  • Provides availability for business-critical applications with redundant hot-swap power supplies and redundant hot-swap fans.
  • Simplifies servicing, speeds up problem resolution, and helps improve system availability with light path diagnostics.
  • Allows preventive actions in advance of possible failure, thereby increasing server uptime and application availability with Proactive Platform Alerts (including PFA and SMART alerts) for processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, flash storage adapters), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures.
  • Continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure to minimize downtime with Built-in XClarity Controller (XCC).
  • Provides quick access to system status, firmware, network, health, and alerts information via Virtual Operator Panel from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access.
  • Speeds up troubleshooting tasks to reduce service time with diagnostics built into the XClarity Provisioning Manager.

Manageability and security

Powerful systems management features simplify local and remote management of the SR630 server and deliver enterprise-class data protection:

  • Provides advanced service processor control, monitoring, and alerting functions with XClarity Controller, a next generation service processor.
  • Improves Unified Extensible Firmware Interface (UEFI) system setup, configuration, updates, simplified error handling, and operating system deployment with the embedded XClarity Provisioning Manager.
  • Offers XClarity Essentials software tools that can help you set up, use, and maintain the server.
  • Increases uptime, reduces costs, and improves productivity through advanced server management capabilities with Lenovo XClarity Administrator that provides comprehensive hardware management.
  • Provides on-the-go monitoring and management of devices in XClarity Administrator from anywhere with the Lenovo XClarity mobile app, which can help improve efficiency and reduce downtime risks.
  • Centralizes infrastructure resource management with Lenovo XClarity Integrators for VMware vCenter and Microsoft System Center, extending XClarity Administrator features to virtualization management software tools and enabling users to deploy and manage infrastructure end-to-end.
  • Offers advanced cryptographic functionality (such as digital signatures and remote attestation) with an integrated Trusted Platform Module (TPM) or optional Trusted Cryptographic Module (TCM) or Nationz TPM (available only in PRC).
  • Keeps user data safe with Lenovo Business Vantage, a security software tool suite designed to work with the Trusted Cryptographic Module (available only in PRC).
  • Offers enterprise-class data protection with advanced RAID and optional self-encrypting drives.
  • Provides faster, stronger encryption with industry-standard AES NI support.
  • Helps prevent certain classes of malicious buffer overflow attacks with Intel Execute Disable Bit functionality, when combined with a supporting operating system.
  • Enhances security through hardware-based resistance to malicious software attacks with Intel Trusted Execution Technology, allowing an application to run in its own isolated space, protected from all other software running on a system.

Energy efficiency

The SR630 server offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Delivers impressive compute power per watt, featuring 80 PLUS Titanium and Platinum redundant power supplies.
  • Enables customers to lower energy costs with design to meet ASHRAE A4 standards in select configurations.
  • Reduces power drawn with Intel Intelligent Power Capability that powers individual processor elements on and off as needed.
  • Helps reduce power consumption with variable speed fans.
  • Helps achieve lower heat output and reduced cooling needs with Lenovo XClarity Energy Manager that provides advanced data center power notification, analysis, and policy-based management.

Components and connectors

The following figure shows the front of the SR630 server with four 3.5-inch drive bays.

Front view of the SR630: 4x 3.5-inch drive bays
Figure 2. Front view of the SR630: 4x 3.5-inch drive bays

The following figure shows the front of the SR630 server with eight 2.5-inch drive bays.

Front view of the SR630: 8x 2.5-inch drive bays
Figure 3. Front view of the SR630: 8x 2.5-inch drive bays

The following figure shows the front of the SR630 server with ten 2.5-inch drive bays.

Front view of the SR630: 10x 2.5-inch drive bays
Figure 4. Front view of the SR630: 10x 2.5-inch drive bays

The front of the SR630 server includes the following components:

  • 4x 3.5-inch, or 8x 2.5-inch, or 10x 2.5-inch hot-swap drive bays.
  • One VGA port (optional).
  • One USB 3.0 port.
  • One USB 2.0 port with XClarity Controller access.
  • Power button.
  • Status LEDs.

The following figure shows the rear of the SR630 server with three PCIe low profile slots.

Rear view of the SR630
Figure 5. Rear view of the SR630

The rear of the SR630 server includes the following components:

  • Up to three PCIe expansion slots (depending on the riser cards selected).
  • One LOM card slot.
  • One 1 GbE port for XClarity Controller.
  • One VGA port.
  • Two USB 3.0 ports.
  • Up to two hot-swap power supplies.

The following figure shows the locations of key components inside the SR630 server.

Internal view of the SR630
Figure 6. Internal view of the SR630

The following key components are located inside the SR630 server:

  • Up to two processors.
  • 24 DIMM slots (12 DIMM slots per processor).
  • Drive backplanes.
  • Two onboard NVMe PCIe connectors.
  • One M.2 module connector.
  • One LOM card connector.
  • One onboard PCIe slot 4.
  • Two slots for PCIe riser cards.
  • One TCM connector.
  • Five (one processor) or seven (two processors) hot-swap system fans.

Standard specifications

The following table lists the system specifications for the SR630 server.

Table 1. SR630 system specifications
Attribute Specification
Machine types 7X01 - 1 year warranty
7X02 - 3 year warranty
Form factor 1U rack-mount
Processor Up to two 2nd Gen Intel Xeon Bronze, Silver, Gold, or Platinum processors:
  • Up to 28 cores (2.7 GHz core speeds).
  • Up to 3.8 GHz core speeds (4 cores).
  • UPI links up to 10.4 GT/s (2 UPI links used).
  • Up to 38.5 MB cache.
  • Up to 2933 MHz memory speed.

1st Gen Intel Xeon processors are also supported.

Chipset Intel C624
Memory Up to 24 DIMM sockets (12 DIMMs per processor; six memory channels per processor with two DIMMs per channel). Support for RDIMMs, LRDIMMs (1st Gen processors only), or 3DS RDIMMs. Memory speed up to 2933 MHz depending on the processor selected. Memory types cannot be intermixed.
Persistent memory Up to 12x TruDDR4 2666 MHz DCPMMs in the DIMM slots. Not supported with 1st Gen Intel Xeon SP processors.
Memory capacity
  • Memory DIMMs only: Up to 3 TB with up to 24x 128 GB 3DS RDIMMs (Up to 1.5 TB per processor).
  • Memory DIMMs and persistent memory modules:
    • App Direct Mode: Up to 7.5 TB with up to 12x 128 GB 3DS RDIMMs and up to 12x 512 GB DCPMMs (Up to 3.75 TB per processor).
    • Memory Mode: Up to 6 TB with up to 12x 512 GB DCPMMs (Up to 3 TB per processor).
Note: Server configurations with more than 1 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 2 TB (M-suffix) or 4.5 TB (L-suffix) per socket. Server configurations with more than 2 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 4.5 TB per socket (L-suffix).
Memory protection
  • Processor's integrated memory controllers: Error correction code (ECC), SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs, requires Intel Xeon Gold or Platinum processors), memory mirroring, memory rank sparing, patrol scrubbing, and demand scrubbing.
  • DCPMM's onboard memory controllers: ECC, SDDC, DDDC, patrol scrubbing, and demand scrubbing.
Note: In the configurations with DCPMMs, memory mirroring is supported only in the App Direct mode (other DCPMM modes do not support memory mirroring) and applies only to the RDIMMs or 3DS RDIMMs (DCPMMs are not mirrored). Memory sparing is not supported in the configurations with DCPMMs.
Drive bays
  • Up to 6 SAS/SATA hot-swap drive bays: 4x 3.5" (front) + 2x 2.5" (rear)
  • 4 LFF AnyBay hot-swap drive bays: 4x 3.5" (front)
  • Up to 10 SFF SAS/SATA hot-swap drive bays: 8x 2.5" (front) + 2x 2.5" (rear)
  • Up to 12 SFF hot-swap drive bays: 
    6x 2.5" SAS/SATA & 4x 2.5" AnyBay (front) + 2x 2.5" SAS/SATA (rear)
  • 10 SFF U.2 NVMe PCIe SSD hot-swap drive bays
Internal storage capacity
  • 2.5-inch drives:
    • 368.64TB using 12x 30.72TB 2.5-inch SAS/SATA SSDs
    • 153.6TB using 10x 15.36TB 2.5-inch NVMe SSDs
    • 28.8TB using 12x 2.4TB 2.5-inch HDDs
  • 3.5-inch drives:
    • 80TB using 4x 20TB 3.5-inch HDDs
    • 61.44TB using 4x 15.36TB 3.5-inch SAS/SATA SSDs
    • 30.72TB using 4x 7.68TB 3.5-inch NVMe SSDs
Storage controller
  • 12 Gb SAS/SATA RAID adapters with up to 8GB flash-backed cache
  • 12 Gb SAS/SATA HBA (non-RAID)
  • Onboard PCIe NVMe (with Intel VROC NVMe RAID support for Intel SSDs and optionally non-Intel SSDs)
  • NVMe Switch Adapters (with Intel VROC NVMe RAID support for Intel SSDs and optionally non-Intel SSDs)
Optical drive bays None. Support for an external USB DVD RW Optical Disk Drive (See Optical drives).
Network interfaces
  • Onboard LOM slot for up to 4x 1/10 Gb Ethernet ports:
    • 2x or 4x 1 GbE RJ-45 ports (no 10/100 Mb support)
    • 2x or 4x 10 GbE RJ-45 ports (no 10/100 Mb support)
    • 2x or 4x 10 GbE SFP+ ports (no 10/100 Mb support)
  • Optional Mezzanine LOM (ML2) slot for dual-port 10 GbE cards with SFP+ or RJ-45 connectors or single- or dual-port 25 GbE cards with SFP28 connectors.
  • 1x RJ-45 10/100/1000 Mb Ethernet systems management port.
I/O expansion slots Up to four slots. Slot 4 is the fixed slot on the system planar, and the remaining slots depend on the riser cards installed. The slots are as follows:
  • Slot 1: PCIe 3.0 x8, ML2 x8, or ML2 x16; low profile
  • Slot 2: PCIe 3.0 x16 or x8; low profile or full-height, half-length
  • Slot 3: PCIe 3.0 x16; low profile
  • Slot 4: PCIe 3.0 x8 (dedicated to an internal storage controller)
Slot 3 requires the second processor to be installed.
Ports
  • Front: 1x USB 2.0 port with XClarity Controller access and 1x USB 3.0 port; optional 1x VGA port.
  • Rear: 2x USB 3.0 ports and 1x VGA port. Optional 1x DB-9 serial port.
Cooling Five (one processor) or seven (two processors) hot-swap dual-rotor system fans with N+1 redundancy.
Power supply Up to two redundant hot-swap 550 W, 750 W, or 1100 W (100 - 240 V) High Efficiency Platinum, or 750 W (200 - 240 V) High Efficiency Titanium AC power supplies. HVDC support (PRC only).
Video Matrox G200e with 16 MB memory integrated into the XClarity Controller. Maximum resolution is 1920x1200 at 60 Hz with 32 bits per pixel.
Hot-swap parts Drives, power supplies, and fans.
Systems management XClarity Controller (XCC) Standard, Advanced, or Enterprise (Pilot 4 chip), proactive platform alerts, light path diagnostics, XClarity Provisioning Manager, XClarity Essentials, XClarity Administrator, XClarity Integrators for VMware vCenter and Microsoft System Center, XClarity Energy Manager, Capacity Planner.
Security features Power-on password, administrator's password, secure firmware updates, Trusted Platform Module (TPM) 1.2 or 2.0 (configurable UEFI setting). Optional lockable front bezel. Optional Trusted Cryptographic Module (TCM) or Nationz TPM (available only in PRC). Optional Lenovo Business Vantage security software (available only in PRC).
Operating systems Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating systems section for specifics.
Warranty One-year (Machine Type 7X01) or three-year (Machine Type 7X02) customer-replaceable unit (CRU) and onsite limited warranty with 9x5 Next Business Day Parts Delivered.
Service and support Optional service upgrades are available through Lenovo Services: 2-hour or 4-hour response time, 6-hour or 24-hour committed service repair (select areas), warranty extension up to 5 years, 1-year or 2-year post-warranty extensions, YourDrive Your Data, Enterprise Software Support, and Basic Hardware Installation Services.
Dimensions Width: 435 mm (17.1 in.), height: 43 mm (1.7 in.), depth: 750 mm (29.5 in.). See Physical specifications for details.
Weight Minimum configuration: 11.9 kg (26.2 lb), maximum: 18.8 kg (41.4 lb)

Models

ThinkSystem SR630 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SR630 as listed in the columns in the following table:

  • General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
  • AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.

Preconfigured server models may also be available for the SR630, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.

The following table lists the base CTO models of the ThinkSystem SR630 server.

Table 2. Base CTO models
Machine Type/Model
General purpose
Machine Type/Model
for AI and HPC
Description
7X02CTO1WW 7X02CTOLWW ThinkSystem SR630 – 3-year warranty
7X01CTO1WW 7X01CTOLWW ThinkSystem SR630 – 1-year warranty

For CTO orders, the following table lists the base chassis feature codes for the server.

There are currently two base feature codes for each of the 2.5-inch and 3.5-inch chassis. The "v2" bases include the new SR570 Air Duct Kit v2 which is required if a RAID 9350 adapter is to be configured. See the RAID flash power module (supercap) support section for details. The non-v2 bases can be selected if any other RAID adapter or HBA is selected.

Table 3. Base chassis for CTO models
Feature code Description
Base feature codes - suitable for all configurations except those with a RAID 9350 adapter
AUW0 ThinkSystem SR630 2.5" Chassis with 8 Bays
AUW1 ThinkSystem SR630 2.5" Chassis with 10 Bays
AUW2 ThinkSystem SR630 3.5" Chassis with 4 Bays
Base feature codes - suitable for all configurations including ones with a RAID 9350 adapter (includes the SR630 Air Duct Kit v2)
BNPP ThinkSystem SR630 2.5" Chassis with 8 Bays v2
BNPN ThinkSystem SR630 2.5" Chassis with 10 Bays v2
BNPQ ThinkSystem SR630 3.5" Chassis with 4 Bays v2

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Common to all models:

  • All models indicated as having the 750W power supply are using the Platinum power supply

Models for Australia and New Zealand

Table 4. Models for Australia and New Zealand
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A0BSAU 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BTAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BXAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0HHAU 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 Option Option 2.5"/8, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BPAU 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BQAU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 530-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BRAU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BYAU 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0HJAU 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0F2AU 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2666 730-8i 2GB 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide CMA
7X02A0F3AU 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide CMA
7X02A0BNAU 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0C0AU 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0FYAU 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0BVAU 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BZAU 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0FWAU 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0BWAU 1x Gold 5217 8C 115W 3.0G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0BUAU 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA
7X02A0FVAU 1x Gold 6226R 16C 150W 2.9G 1x 64GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0FXAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0FZAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0HKAU 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide CMA

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for South East Asian countries (ASEAN)

Table 5. Models for South East Asian countries (ASEAN)
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A09DSG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ACSG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08CSG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08KSG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A087SG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A095SG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08PSG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09WSG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08ESG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0B2SG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0A5SG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AZSG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08USG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09VSG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A07ZSG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08TSG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A099SG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09XSG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08QSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AUSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08FSG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08HSG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AYSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BLSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ATSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BJSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A091SG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BMSG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A082SG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09TSG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Brazil

Table 6. Models for Brazil
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X02)
7X02A0CYBR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0D6BR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Opt Std Slide
7X02A0D1BR 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0GHBR 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 2x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
7X02A0GKBR 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 2x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
7X02A0GGBR 1x Gold 6240R 24C 165W 2.4G 2x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 4x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
7X02A0GJBR 1x Gold 6240R 24C 165W 2.4G 2x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 4x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
SAP HANA Business One models with a 3-year warranty (machine type 7X02)
7X02A0DZBR 2x Silver 4210 10C 85W 2.2G 12x 8GB 2933 930-8i 8x 2.5" SAS, 3x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0E0BR 2x Silver 4210 10C 85W 2.2G 12x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 3x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0E1BR 2x Silver 4210 10C 85W 2.2G 12x 8GB 2933 930-8i 8x 2.5" SAS, 3x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0E2BR 2x Silver 4210 10C 85W 2.2G 12x 32GB 2933 930-8i 8x 2.5" SAS, 4x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0E3BR 2x Silver 4214 12C 85W 2.2G 12x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 5x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0E4BR 2x Silver 4214 12C 85W 2.2G 12x 64GB 2933 930-8i 8x 2.5" SAS, 5x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0E5BR 2x Silver 4214 12C 85W 2.2G 24x 64GB 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), 9x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A0GSBR 1x Bronze 3204 6C 85W 1.9G 1x 32GB 2933 730-8i 2GB 4x 3.5" SAS, 2x 4TB SATA HDD 4x1Gb x8 LP, x16 LP 2x 750W Yes Std Slide
7X02A0D8BR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Opt Std Slide
7X02A0F5BR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 2x 750W Opt Ent Slide
7X02A0F9BR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 2x 750W Opt Std Slide
7X02A0G3BR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 4x 3.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 2x 750W Yes Std Slide
7X02A0G7BR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 4x 3.5" SAS, 1x 2TB SATA HDD 4x1Gb x8 LP, x16 LP 2x 750W Yes Std Slide
7X02A0GTBR 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 4x 3.5" SAS, 2x 4TB SATA HDD 4x1Gb x8 LP, x16 LP 2x 750W Yes Std Slide
7X02A0CZBR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0D9BR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Opt Std Slide
7X02A0F8BR 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 2x 750W Opt Std Slide
7X02A0FSBR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 2x 750W Opt Std Slide
7X02A0GUBR 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 730-8i 2GB 4x 3.5" SAS, 2x 4TB SATA HDD 4x1Gb x8 LP, x16 LP 2x 750W Yes Std Slide
7X02A0D0BR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0DABR 1x Silver 4214 12C 85W 2.2G 1x 32GB 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Opt Std Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for EMEA region

Table 7. Models for EMEA region
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
SAP HANA Business One models with a 3-year warranty (machine type 7X02)
7X02A0HLEA 2x Silver 4210R 10C 100W 2.4G 12x 16GB 1Rx4 2933 940-8i 4GB 8x 2.5" SAS, 3x 960GB S4620 4x1Gb x8 LP, x16 LP, x16 LP 2x 750W Yes Ent Slide CMA
Standard models with a 3-year warranty (machine type 7X02)
7X02A0EPEA 1x Bronze 3206R 8C 85W 1.9G 1x 32GB 2933 530-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A07REA 1x Silver 4110 8C 85W 2.1G 1x 16GB 2Rx8 2666 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X021019EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, 2x 480GB MV SSD Open Open 2x 750W Opt Ent Slide
7X02101AEA 1x Silver 4208 8C 85W 2.1G 2x 32GB 2933 930-8i 8x 2.5" SAS, 2x 480GB MV SSD 4x1Gb x8 LP, x16 LP 2x 750W Opt Ent Slide
7X02A0A9EA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0CSEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay, M.2 Dual, 2x 240GB 5100 M.2 Open Open 1x 750W Opt Std Opt
7X02A0F1EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0FTEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, 2x 480GB MV SSD Open x8 LP, x16 LP 2x 750W Opt Ent Slide
7X02A0G8EA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GPEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, 2x 240GB S4510 Open Open 2x 750W Opt Ent Slide
7X02A0GXEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HFEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HQEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HTEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JCEA 1x Silver 4208 8C 85W 2.1G 1x 64GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JREA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A0JVEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 Option Option 2.5"/8, Open bay, M.2 Dual Open Open 1x 750W TT Opt Ent Slide
7X02A0JXEA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 530-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A0K0EA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A088EA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0AGEA 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0AQEA 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2666 530-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0AXEA 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 4x 3.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0CTEA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay, M.2 Dual, 2x 240GB 5100 M.2 Open Open 1x 750W Opt Std Opt
7X02A0EEEA 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0EMEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 530-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0F0EA 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0F4EA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GAEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GQEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS, 2x 480GB 5400 PRO Open Open 2x 750W Opt Ent Slide
7X02A0GWEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HEEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HPEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HUEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JDEA 1x Silver 4210R 10C 100W 2.4G 1x 64GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JSEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A0JYEA 1x Silver 4210R 10C 100W 2.4G 1x 32GB 2933 530-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A0JZEA 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 530-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A08REA 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0EFEA 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0ETEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GBEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H7EA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HCEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HWEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JTEA 1x Silver 4214R 12C 100W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A08SEA 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0GFEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H6EA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HBEA 1x Silver 4215 8C 85W 2.5G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0JFEA 1x Silver 4215 8C 85W 2.5G 1x 64GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0EGEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0EHEA 1x Silver 4215R 8C 130W 3.2G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0EJEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 530-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0ELEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GCEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H4EA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HAEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HVEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JGEA 1x Silver 4215R 8C 130W 3.2G 1x 64GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JWEA 1x Silver 4215R 8C 130W 3.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A0B4EA 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0G9EA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H2EA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H5EA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0HXEA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0HYEA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0JUEA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W TT Opt Ent Slide
7X02A0B7EA 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 1100W Opt Ent Slide
7X02A085EA 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2666 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open Open 1x 750W Opt Ent Slide
7X02A0AHEA 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2666 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0EAEA 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X021017EA 2x Gold 5218R 20C 125W 2.1G 2x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0EUEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0EZEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GDEA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H0EA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H3EA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0EYEA 1x Gold 5220R 24C 150W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0B6EA 1x Gold 5222 4C 105W 3.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0E6EA 1x Gold 6226 12C 125W 2.7G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0EXEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GEEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0GZEA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 940-8i 4GB 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0H1EA 1x Gold 6226R 16C 150W 2.9G 1x 32GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0JEEA 1x Gold 6226R 16C 150W 2.9G 1x 64GB 2933 9350-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W TT Opt Ent Slide
7X02A0ALEA 1x Gold 6230 20C 125W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0EWEA 1x Gold 6230R 26C 150W 2.1G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0E8EA 1x Gold 6234 8C 130W 3.3G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0EVEA 1x Gold 6238R 28C 165W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A0ESEA 1x Gold 6240R 24C 165W 2.4G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Ent Slide
7X02A090EA 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 1100W Opt Ent Slide
7X02A0EREA 1x Gold 6242R 20C 205W 3.1G 1x 32GB 2933 930-8i 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 1100W Opt Ent Slide
7X02A093EA 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 1100W Opt Ent Slide
7X02A0E9EA 1x Gold 6246 12C 165W 3.3G 1x 32GB 2933 930-8i 8x 2.5" SAS, Open bay Open Open 1x 750W Opt Ent Slide
7X02A0EQEA 1x Gold 6246R 16C 205W 3.4G 1x 32GB 2933 930-8i 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 1100W Opt Ent Slide
7X02A0ENEA 1x Gold 6248R 24C 205W 3.0G 1x 32GB 2933 930-8i 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 1100W Opt Ent Slide
7X02A0EKEA 1x Gold 6258R 28C 205W 2.7G 1x 32GB 2933 930-8i 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 1100W Opt Ent Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Hong Kong, Taiwan, Korea (HTK)

Table 8. Models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X02)
7X021018CN 1x Silver 4215 8C 85W 2.5G 4x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 4x 1.2TB 10K, 2x 480GB S4510, 1x Ext DVDRW 4x1Gb Open 2x 750W Opt Std Slide
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A08VCN 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AECN 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09ECN 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0B3CN 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A089CN 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ARCN 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A083CN 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09JCN 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09ZCN 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0APCN 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09FCN 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BGCN 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0A6CN 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BFCN 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08JCN 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09CCN 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A07YCN 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ABCN 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A098CN 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AVCN 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08BCN 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09KCN 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A086CN 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09RCN 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08ZCN 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BBCN 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09HCN 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0A0CN 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08DCN 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0A1CN 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for India

Table 9. Models for India
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A08GSG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0B5SG 1x Bronze 3204 6C 85W 1.9G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0HNSG 1x Bronze 3204 6C 85W 1.9G 1x 8GB 2933 530-8i 4x 3.5" SAS, 1x 1TB SATA HDD Open x8 LP, x16 LP 1x 550W Opt Ent Slide CMA
7X02A0A3SG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0A8SG 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AASG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BASG 1x Silver 4210 10C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08LSG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BCSG 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09USG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ASSG 1x Silver 4215 8C 85W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A07XSG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09PSG 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A081SG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A097SG 1x Gold 5215 10C 85W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A094SG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09ASG 1x Gold 5217 8C 115W 3.0G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A092SG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A096SG 1x Gold 5218 16C 125W 2.3G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08XSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09YSG 1x Gold 5220 18C 125W 2.2G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09SSG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AJSG 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08MSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0BDSG 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0AKSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ANSG 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A08ASG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A09GSG 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0ADSG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt
7X02A0B0SG 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 930-8i 4x 3.5" SAS, Open bay Open x8 LP, x16 LP 1x 750W Opt Std Opt

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Japan

Table 10. Models for Japan
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X02)
7X02101HJP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 1Rx4 2933 9350-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0J8JP 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 730-8i 2GB 4x 3.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0J9JP 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02101MJP 1x Silver 4209T 8C 70W 2.2G 1x 16GB 1Rx4 2933 9350-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02101GJP 1x Silver 4210 10C 85W 2.2G 1x 16GB 1Rx4 2933 9350-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0JAJP 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0JBJP 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0FLJP 1x Silver 4215R 8C 130W 3.2G 1x 16GB 1Rx4 2666 Option Option 2.5"/8, Open bay 4x1Gb Open 1x 550W Opt Adv Slide
7X02101JJP 1x Gold 5218 16C 125W 2.3G 1x 16GB 1Rx4 2933 9350-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0FFJP 1x Gold 5218R 20C 125W 2.1G 1x 16GB 1Rx4 2666 Option Option 2.5"/8, Open bay 4x1Gb Open 1x 550W Opt Adv Slide
7X02A0J7JP 1x Gold 5218R 20C 125W 2.1G 1x 16GB 2Rx8 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0FJJP 1x Gold 5220R 24C 150W 2.2G 1x 16GB 1Rx4 2666 Option Option 2.5"/8, Open bay 4x1Gb Open 1x 750W Opt Adv Slide
7X02101KJP 1x Gold 5222 4C 105W 3.8G 1x 16GB 1Rx4 2933 9350-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0BKJP 1x Gold 6242 16C 150W 2.8G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0BEJP 1x Gold 6244 8C 150W 3.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0AFJP 1x Gold 6248 20C 150W 2.5G 1x 16GB 2Rx8 2933 930-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A080JP 1x Gold 6252 24C 150W 2.1G 1x 16GB 2Rx8 2933 1610-4P NVMe 10x 2.5" NVMe, Open bay 4x1Gb x8 LP, x16 LP 1x 1100W Opt Adv Slide
7X02A0BHJP 1x Gold 6254 18C 200W 3.1G 1x 16GB 2Rx8 2933 Option Option 2.5"/10, Open bay 4x1Gb x8 LP, x16 LP 1x 1100W Opt Adv Slide
7X02A09QJP 1x Platinum 8276 28C 165W 2.2G 1x 16GB 2Rx8 2933 930-8i 10x 2.5" (6xSAS + 4xAny), Open bay 4x1Gb x8 LP, x16 LP 1x 1100W Opt Adv Slide
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A084JP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A0B8JP 1x Bronze 3204 6C 85W 1.9G 1x 16GB 1Rx4 2666 530-8i 4x 3.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A0FEJP 1x Bronze 3206R 8C 85W 1.9G 1x 16GB 1Rx4 2666 Option Option 2.5"/8, Open bay 4x1Gb Open 1x 550W Opt Adv Slide
7X02A09BJP 1x Silver 4208 8C 85W 2.1G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A08WJP 1x Silver 4210 10C 85W 2.2G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A0B9JP 1x Silver 4210 10C 85W 2.2G 1x 16GB 1Rx4 2666 530-8i 4x 3.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A0FNJP 1x Silver 4210R 10C 100W 2.4G 1x 16GB 1Rx4 2666 Option Option 2.5"/8, Open bay 4x1Gb Open 1x 550W Opt Adv Slide
7X02A08YJP 1x Silver 4214 12C 85W 2.2G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A0FMJP 1x Silver 4214R 12C 100W 2.4G 1x 16GB 1Rx4 2666 Option Option 2.5"/8, Open bay 4x1Gb Open 1x 550W Opt Adv Slide
7X02A09LJP 1x Silver 4215 8C 85W 2.5G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A08NJP 1x Silver 4216 16C 100W 2.1G 1x 16GB 1Rx4 2666 530-8i 4x 3.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A09MJP 1x Silver 4216 16C 100W 2.1G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 550W Opt Adv Slide
7X02A09NJP 1x Gold 5215 10C 85W 2.5G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0B1JP 1x Gold 5217 8C 115W 3.0G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0AMJP 1x Gold 5218 16C 125W 2.3G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0A2JP 1x Gold 5220 18C 125W 2.2G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0A4JP 1x Gold 5222 4C 105W 3.8G 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0A7JP 1x Gold 6230 20C 125W 2.1G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide
7X02A0AWJP 1x Gold 6240 18C 150W 2.6G 1x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 LP 1x 750W Opt Adv Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for Latin American countries (except Brazil)

Table 11. Models with a 3-year warranty for Latin American countries (except Brazil)
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X02)
7X02A0CULA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0G6LA 1x Silver 4210R 10C 100W 2.4G 1x 16GB 2Rx8 2933 730-8i 1GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0G4LA 1x Silver 4214R 12C 100W 2.4G 1x 16GB 2Rx8 2933 730-8i 1GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0CXLA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0G5LA 1x Gold 5218R 20C 125W 2.1G 1x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 2x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
7X02A0G2LA 1x Gold 6230R 26C 150W 2.1G 2x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 4x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
7X02A0G1LA 1x Gold 6240R 24C 165W 2.4G 2x 32GB 2933 930-16i 4GB 8x 2.5" SAS, Open bay 4x10Gb RJ45 x8 LP, x16 FH 2x 750W Yes Ent Slide
SAP HANA Business One models with a 3-year warranty (machine type 7X02)
7X02A0DKLA 2x Silver 4210 10C 85W 2.2G 12x 8GB 2933 930-8i 8x 2.5" SAS, 4x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DLLA 2x Silver 4210 10C 85W 2.2G 12x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 5x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DMLA 2x Silver 4210 10C 85W 2.2G 12x 8GB 2933 930-8i 8x 2.5" SAS, 6x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DNLA 2x Silver 4210 10C 85W 2.2G 12x 32GB 2933 930-8i 8x 2.5" SAS, 6x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DSLA 2x Silver 4210 10C 85W 2.2G 12x 8GB 2933 930-8i 8x 2.5" SAS, 3x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DTLA 2x Silver 4210 10C 85W 2.2G 12x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 3x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DULA 2x Silver 4210 10C 85W 2.2G 12x 8GB 2933 930-8i 8x 2.5" SAS, 3x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DVLA 2x Silver 4210 10C 85W 2.2G 12x 32GB 2933 930-8i 8x 2.5" SAS, 4x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DPLA 2x Silver 4214 12C 85W 2.2G 12x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 7x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DQLA 2x Silver 4214 12C 85W 2.2G 12x 64GB 2933 930-8i 8x 2.5" SAS, 8x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DRLA 2x Silver 4214 12C 85W 2.2G 24x 64GB 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), 10x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DWLA 2x Silver 4214 12C 85W 2.2G 12x 16GB 2Rx8 2933 930-8i 8x 2.5" SAS, 5x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DXLA 2x Silver 4214 12C 85W 2.2G 12x 64GB 2933 930-8i 8x 2.5" SAS, 5x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
7X02A0DYLA 2x Silver 4214 12C 85W 2.2G 24x 64GB 2933 930-16i 4GB 10x 2.5" (6xSAS + 4xAny), 9x 960GB S4610 4x1Gb Open 2x 750W Opt Ent Slide
TopSeller models with a 3-year warranty (machine type 7X02)
7X02A0CVLA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide
7X02A0CWLA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 730-8i 2GB 8x 2.5" SAS, Open bay 4x1Gb x8 LP, x16 FH 1x 750W Yes Std Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Models for USA and Canada

Table 12. Models for USA and Canada
Model Intel Xeon Scalable processor† Memory RAID Front drive bays and drives LOM Rear
Slots
Power
supply
Front
VGA
XCC Rail
kit
Standard models with a 3-year warranty (machine type 7X02)
7X021014NA 1x Silver 4208 8C 85W 2.1G 1x 8GB 2933 Option Option 2.5"/8, Open bay 2x1Gb x8 LP, x16 LP 1x 1100W Opt Adv Slide
7X02A0CENA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0FANA 1x Silver 4208 8C 85W 2.1G 1x 16GB 2Rx8 2933 530-8i 4x 3.5" SAS, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0HDNA 1x Silver 4208 8C 85W 2.1G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02101PNA 1x Silver 4210 10C 85W 2.2G 1x 32GB 2933 930-8i 8x 2.5" SAS, 1x 1.92TB S4620 Open x8 LP, x16 FH 2x 1100W Yes Ent Slide
7X02A0CGNA 1x Silver 4214 12C 85W 2.2G 1x 16GB 2Rx8 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0H8NA 1x Silver 4214 12C 85W 2.2G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0CJNA 1x Silver 4216 16C 100W 2.1G 1x 16GB 2Rx8 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0GYNA 1x Silver 4216 16C 100W 2.1G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0CKNA 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X02A0H9NA 1x Gold 5218 16C 125W 2.3G 1x 32GB 2933 Option Option 2.5"/8, Open bay Open Open 1x 750W Yes Ent Slide
7X021015NA 1x Gold 5222 4C 105W 3.8G 1x 8GB 2933 Option Option 2.5"/8, Open bay 2x1Gb x8 LP, x16 LP 1x 1100W Opt Adv Slide
7X021016NA 1x Gold 6208U 16C 150W 2.9G 1x 8GB 2933 Option Option 2.5"/8, Open bay 2x1Gb x8 LP, x16 LP 1x 1100W Opt Adv Slide

† Processor description: Processor model, number of cores, thermal design power (TDP), core frequency

Processors

The SR630 server supports one or two Intel Xeon Bronze, Silver, Gold, or Platinum processors. The following table lists the specifications of the processors for the SR630 server.

Topics in this section:

Processor specifications

Processor support: Both 1st Gen and 2nd Gen Intel Xeon SP processors are supported. For supported 1st Gen processors, see the Continued support for 1st Gen Intel Xeon Scalable processors section.

Abbreviations used in the table:

  • UPI: Ultra Path Interconnect
  • TDP: Thermal Design Power
  • HT: Hyper-Threading
  • TB: Turbo Boost 2.0
  • VT-x: Virtualization Technology
  • VT-d: Virtualization Technology for Directed I/O
  • SST-PP: Speed Select Technology - Performance Profile
  • FMA: Fused-Multiply Add (AVX-512)
  • DCPMM: DC Persistent Memory Module
  • RAS: Reliability, Availability, and Serviceability
    • Std: Standard RAS
    • Adv: Advanced RAS
Table 13. Processor specifications
CPU
model
Cores /
threads
Core speed
(Base / TB Max)
Cache Max DDR4
speed
Max memory
capacity
per socket
UPI
speed
TDP
HT
TB
VT-x
VT-d
SST-PP
FMA units
DCPMM
RAS
Intel Xeon Bronze processors
3204 6 / 6 1.9 / 1.9 GHz 8.25 MB 2133 MHz 1 TB 9.6 GT/s 85 W N N Y Y N 1 N Std
3206R 8 / 8 1.9 / 1.9 GHz 11 MB 2133 MHz 1 TB 9.6 GT/s 85 W N N Y Y N 1 N Std
Intel Xeon Silver processors
4208 8 / 16 2.1 / 3.2 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 N Std
4209T 8 / 16 2.2 / 3.2 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 70 W Y Y Y Y N 1 N Std
4210 10 / 20 2.2 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 N Std
4210R 10 / 20 2.4 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 9.6 GT/s 100 W Y Y Y Y N 1 N Std
4210T 10 / 20 2.3 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 9.6 GT/s 95 W Y Y Y Y N 1 N Std
4214 12 / 24 2.2 / 3.2 GHz 16.5 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 N Std
4214R 12 / 24 2.4 / 3.5 GHz 16.5 MB 2400 MHz 1 TB 9.6 GT/s 100 W Y Y Y Y N 1 N Std
4214Y 12 / 24 2.2 / 3.2 GHz 16.5 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y Y 1 N Std
10 / 20 2.3 / 3.2 GHz
8 / 16 2.4 / 3.2 GHz
4215 8 / 16 2.5 / 3.5 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 85 W Y Y Y Y N 1 Y Std
4215R 8 / 16 3.2 / 4.0 GHz 11 MB 2400 MHz 1 TB 9.6 GT/s 130 W Y Y Y Y N 1 Y Std
4216 16 / 32 2.1 / 3.2 GHz 22 MB 2400 MHz 1 TB 9.6 GT/s 100 W Y Y Y Y N 1 N Std
Intel Xeon Gold processors
5215 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 1 TB 10.4 GT/s 85 W Y Y Y Y N 1 Y Adv
5215M 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 2 TB 10.4 GT/s 85 W Y Y Y Y N 1 Y Adv
5215L 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 4.5 TB 10.4 GT/s 85 W Y Y Y Y N 1 Y Adv
5217 8 / 16 3.0 / 3.7 GHz 11 MB 2666 MHz 1 TB 10.4 GT/s 115 W Y Y Y Y N 1 Y Adv
5218 16 / 32 2.3 / 3.9 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5218B 16 / 32 2.3 / 3.9 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5218R 20 / 40 2.1 / 4.0 GHz 27.5 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5218N 16 / 32 2.3 / 3.7 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 110 W Y Y Y Y N 1 Y Adv
5218T 16 / 32 2.1 / 3.8 GHz 22 MB 2666 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 1 Y Adv
5220 18 / 36 2.2 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5220R 24 / 48 2.2 / 4.0 GHz 35.75 MB 2666 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 1 Y Adv
5220S 18 / 36 2.7 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 1 Y Adv
5220T 18 / 36 1.9 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 1 Y Adv
5222 4 / 8 3.8 / 3.9 GHz 16.5 MB 2933 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 2 Y Adv
6208U 16 / 32 2.9 / 3.9 GHz 22 MB 2933 MHz 1 TB No UPI 150 W Y Y Y Y N 2 Y Adv
6222V 20 / 40 1.8 / 3.6 GHz 27.5 MB 2400 MHz 1 TB 10.4 GT/s 115 W Y Y Y Y N 2 Y Adv
6226 12 / 24 2.7 / 3.7 GHz 19.25 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6226R 16 / 32 2.9 / 3.9 GHz 22 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6230 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6230N 20 / 40 2.3 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6230R 26 / 52 2.1 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6230T 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6234 8 / 16 3.3 / 4.0 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 130 W Y Y Y Y N 2 Y Adv
6238 22 / 44 2.1 / 3.7 GHz 30.25 MB 2933 MHz 1 TB 10.4 GT/s 140 W Y Y Y Y N 2 Y Adv
6238M 22 / 44 2.1 / 3.7 GHz 30.25 MB 2933 MHz 2 TB 10.4 GT/s 140 W Y Y Y Y N 2 Y Adv
6238L 22 / 44 2.1 / 3.7 GHz 30.25 MB 2933 MHz 4.5 TB 10.4 GT/s 140 W Y Y Y Y N 2 Y Adv
6238R 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
6238T 22 / 44 1.9 / 3.7 GHz 30.25 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
6240 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6240M 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 2 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6240L 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 4.5 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6240R 24 / 48 2.4 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
6240Y 18 / 36 2.6 / 3.9 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y Y 2 Y Adv
14 / 28 2.8 / 3.9 GHz
8 / 16 3.1 / 3.9 GHz
6242 16 / 32 2.8 / 3.9 GHz 22 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6242R 20 / 40 3.1 / 4.1 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6244 8 / 16 3.6 / 4.4 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6246 12 / 24 3.3 / 4.2 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
6246R 16 / 32 3.4 / 4.1 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6248 20 / 40 2.5 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6248R 24 / 48 3.0 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6252 24 / 48 2.1 / 3.7 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6252N 24 / 48 2.3 / 3.6 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 150 W Y Y Y Y N 2 Y Adv
6254 18 / 36 3.1 / 4.0 GHz 24.75 MB 2933 MHz 1 TB 10.4 GT/s 200 W Y Y Y Y N 2 Y Adv
6258R 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
6262V 24 / 48 1.9 / 3.6 GHz 33 MB 2400 MHz 1 TB 10.4 GT/s 135 W Y Y Y Y N 2 Y Adv
Intel Xeon Platinum processors
8253 16 / 32 2.2 / 3.0 GHz 22 MB 2933 MHz 1 TB 10.4 GT/s 125 W Y Y Y Y N 2 Y Adv
8256 4 / 8 3.8 / 3.9 GHz 16.5 MB 2933 MHz 1 TB 10.4 GT/s 105 W Y Y Y Y N 2 Y Adv
8260 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8260M 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 2 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8260L 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 4.5 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8260Y 24 / 48 2.4 / 3.9 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y Y 2 Y Adv
20 / 40 2.5 / 3.9 GHz
16 / 32 2.7 / 3.9 GHz
8268 24 / 48 2.9 / 3.9 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8270 26 / 52 2.7 / 4.0 GHz 35.75 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8276 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8276M 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 2 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8276L 28 / 56 2.2 / 4.0 GHz 38.5 MB 2933 MHz 4.5 TB 10.4 GT/s 165 W Y Y Y Y N 2 Y Adv
8280 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 1 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8280M 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 2 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv
8280L 28 / 56 2.7 / 4.0 GHz 38.5 MB 2933 MHz 4.5 TB 10.4 GT/s 205 W Y Y Y Y N 2 Y Adv

Configuration notes:

  • The Intel Xeon Gold 5218 and 5218B processors have similar specifications; however, they use different silicon designs and cannot be mixed in the same system.
  • Processors with a U suffix are only supported in single-processor configurations. This limits the PCIe slots that can be used.
  • The processors that support SST-PP offer three distinct operating points that are defined by a core count with a base speed associated with that core count. The operating point is static, it is selected during the boot process and cannot be changed at runtime.

Processor ordering information

For the SR630 server models that come standard with one processor, the second processor can be ordered, if required (see the following table for ordering information). The second processor must be of the same model as the first processor. The second processor option includes a processor and a heatsink; two additional system fans are not included and need to be purchased with the second processor (see Cooling for details).

Table 14. Processor options
Part number Feature code* Description
Intel Xeon Bronze processors
4XG7A37939 B4HU SR530/SR570/SR630 Intel Xeon Bronze 3204 6C 85W 1.9GHz Processor w/o FAN
4XG7A37990 B7N3 SR530/SR570/SR630 Intel Xeon Bronze 3206R 8C 85W 1.9GHz Processor w/o FAN
Intel Xeon Silver processors
4XG7A37936 B4HT SR530/SR570/SR630 Intel Xeon Silver 4208 8C 85W 2.1GHz Processor w/o FAN
4XG7A37945 B4P4 SR530/SR570/SR630 Intel Xeon Silver 4209T 8C 70W 2.2GHz Processor w/o FAN
4XG7A37933 B4HS SR530/SR570/SR630 Intel Xeon Silver 4210 10C 85W 2.2GHz Processor w/o FAN
4XG7A37988 B7N5 SR530/SR570/SR630 Intel Xeon Silver 4210R 10C 100W 2.4GHz Processor w/o FAN
4XG7A63300 BAZT SR630 Intel Xeon Silver 4210T 10C 95W 2.3GHz Processor w/o FAN
4XG7A37930 B4HR SR530/SR570/SR630 Intel Xeon Silver 4214 12C 85W 2.2GHz Processor w/o FAN
4XG7A37987 B7N6 SR530/SR570/SR630 Intel Xeon Silver 4214R 12C 100W 2.4GHz Processor w/o FAN
4XG7A37942 B4NW SR530/SR570/SR630 Intel Xeon Silver 4214Y 12/10/8C 85W 2.2GHz Processor w/o FAN
4XG7A37927 B4HQ SR530/SR570/SR630 Intel Xeon Silver 4215 8C 85W 2.5GHz Processor w/o FAN
4XG7A63298 BAZU SR570/SR630 Intel Xeon Silver 4215R 8C 130W 3.2GHz Processor w/o FAN
4XG7A37924 B4HP SR530/SR570/SR630 Intel Xeon Silver 4216 16C 100W 2.1GHz Processor w/o FAN
Intel Xeon Gold processors
4XG7A37917 B4HN SR530/SR570/SR630 Intel Xeon Gold 5215 10C 85W 2.5GHz Processor w/o FAN
4XG7A37914 B4P1 SR530/SR570/SR630 Intel Xeon Gold 5215M 10C 85W 2.5GHz Processor w/o FAN
4XG7A37911 B4P9 SR530/SR570/SR630 Intel Xeon Gold 5215L 10C 85W 2.5GHz Processor w/o FAN
4XG7A37920 B4HM SR630 Intel Xeon Gold 5217 8C 115W 3.0GHz Processor w/o FAN
4XG7A37896 B4HL SR530/SR570/SR630 Intel Xeon Gold 5218 16C 125W 2.3GHz Processor w/o FAN
4XG7A37959 B6BS SR530/SR570/SR630 Intel Xeon Gold 5218B 16C 125W 2.3GHz Processor w/o FAN
4XG7A63296 BAZS SR530/SR570/SR630 Intel Xeon Gold 5218R 20C 125W 2.1GHz Processor w/o FAN
4XG7A37956 B5S0 SR630 Intel Xeon Gold 5218N 16C 110W 2.3GHz Processor Option Kit w/o FAN
4XG7A37966 B4P3 SR630 Intel Xeon Gold 5218T 16C 105W 2.1GHz Processor w/o FAN
4XG7A37893 B4HK SR530/SR570/SR630 Intel Xeon Gold 5220 18C 125W 2.2GHz Processor w/o FAN
4XG7A37984 B7N9 SR570/SR630 Intel Xeon Gold 5220R 24C 150W 2.2GHz Processor w/o FAN
4XG7A38018 B6CW SR530/SR570/SR630 Intel Xeon Gold 5220S 18C 125W 2.7GHz Processor w/o FAN
4XG7A15809 B6CQ SR630 Intel Xeon Gold 5220T 18C 105W 1.9GHz Processor w/o Fan
4XG7A37952 B5S1 SR630 Intel Xeon Gold 5222 4C 105W 3.8GHz Processor w/o FAN
None** BAZV Intel Xeon Gold 6208U 16C 150W 2.9GHz Processor
4XG7A38022 B6CV SR530/SR570/SR630 Intel Xeon Gold 6222V 20C 115W 1.8GHz Processor w/o FAN
4XG7A38020 B6CL SR530/SR570/SR630 Intel Xeon Gold 6226 12C 125W 2.7GHz Processor w/o FAN
4XG7A63292 BAZW SR570/SR630 Intel Xeon Gold 6226R 16C 150W 2.9GHz Processor w/o FAN
4XG7A37890 B4HJ SR530/SR570/SR630 Intel Xeon Gold 6230 20C 125W 2.1GHz Processor w/o FAN
4XG7A15720 B5RY SR630 Intel Xeon Gold 6230N 20C 125W 2.3GHz Processor Option Kit w/o FAN
4XG7A63290 BAZX SR570/SR630 Intel Xeon Gold 6230R 26C 150W 2.1GHz Processor w/o FAN
4XG7A15808 B6CP SR630 Intel Xeon Gold 6230T 20C 125W 2.1GHz Processor w/o Fan
4XG7A38000 B6CK SR570/SR630 Intel Xeon Gold 6234 8C 130W 3.3GHz Processor w/o FAN
4XG7A38024 B6CJ SR570/SR630 Intel Xeon Gold 6238 22C 140W 2.1GHz Processor w/o FAN
4XG7A37998 B6CM SR570/SR630 Intel Xeon Gold 6238M 22C 140W 2.1GHz Processor w/o FAN
4XG7A38002 B6CR SR570/SR630 Intel Xeon Gold 6238L 22C 140W 2.1GHz Processor w/o FAN
4XG7A63288 BAZL SR630 Intel Xeon Gold 6238R 28C 165W 2.2GHz Processor w/o FAN
4XG7A37907 B4P2 SR630 Intel Xeon Gold 6238T 22C 125W 1.9GHz Processor w/o FAN
4XG7A37884 B4HH SR570/SR630 Intel Xeon Gold 6240 18C 150W 2.6GHz Processor w/o FAN
4XG7A38012 B6CN SR570/SR630 Intel Xeon Gold 6240M 18C 150W 2.6GHz Processor w/o FAN
4XG7A38014 B6CS SR570/SR630 Intel Xeon Gold 6240L 18C 150W 2.6GHz Processor w/o FAN
4XG7A63286 BAZM SR630 Intel Xeon Gold 6240R 24C 165W 2.4GHz Processor w/o FAN
4XG7A37904 B4NV SR630 Intel Xeon Gold 6240Y 18/14/8C 150W 2.6GHz Processor w/o FAN
4XG7A37887 B4HG SR630 Intel Xeon Gold 6242 16C 150W 2.8GHz Processor w/o FAN
4XG7A63284 BAZN SR630 Intel Xeon Gold 6242R 20C 205W 3.1GHz Processor w/o FAN
4XG7A15875 B4HF SR630 Intel Xeon Gold 6244 8C 150W 3.6GHz Processor w/o FAN
4XG7A37965 B6PD SR630 Intel Xeon Gold 6246 12C 165W 3.3GHz Processor w/o FAN
4XG7A63282 BAZP SR630 Intel Xeon Gold 6246R 16C 205W 3.4GHz Processor w/o FAN
4XG7A15893 B4HE SR570/SR630 Intel Xeon Gold 6248 20C 150W 2.5GHz Processor w/o FAN
4XG7A63280 BAZQ SR630 Intel Xeon Gold 6248R 24C 205W 3.0GHz Processor w/o FAN
4XG7A15890 B4HC SR570/SR630 Intel Xeon Gold 6252 24C 150W 2.1GHz Processor w/o FAN
4XG7A15812 B6CT SR630 Intel Xeon Gold 6252N 24C 150W 2.3GHz Processor w/o FAN
4XG7A15873 B4HD SR630 Intel Xeon Gold 6254 18C 200W 3.1GHz Processor w/o FAN
4XG7A63278 BAZR SR630 Intel Xeon Gold 6258R 28C 205W 2.7GHz Processor w/o FAN
4XG7A38009 B6CU SR570/SR630 Intel Xeon Gold 6262V 24C 135W 1.9GHz Processor w/o FAN
Intel Xeon Platinum processors
4XG7A37899 B5RZ SR530/SR570/SR630 Intel Xeon Platinum 8253 16C 125W 2.2GHz Processor w/o FAN
4XG7A37948 B5S2 SR630 Intel Xeon Platinum 8256 4C 105W 3.8GHz Processor w/o FAN
4XG7A15888 B4HB SR630 Intel Xeon Platinum 8260 24C 165W 2.4GHz Processor w/o FAN
4XG7A15886 B4NZ SR630 Intel Xeon Platinum 8260M 24C 165W 2.4GHz Processor w/o FAN
4XG7A15884 B4P7 SR630 Intel Xeon Platinum 8260L 24C 165W 2.4GHz Processor w/o FAN
4XG7A37902 B4NU SR630 Intel Xeon Platinum 8260Y 24/20/16C 165W 2.4GHz Processor w/o FAN
4XG7A15871 B4HA SR630 Intel Xeon Platinum 8268 24C 205W 2.9GHz Processor w/o FAN
4XG7A15869 B4H9 SR630 Intel Xeon Platinum 8270 26C 205W 2.7GHz Processor w/o FAN
4XG7A15882 B4H8 SR630 Intel Xeon Platinum 8276 28C 165W 2.2GHz Processor w/o FAN
4XG7A15880 B4NY SR630 Intel Xeon Platinum 8276M 28C 165W 2.2GHz Processor w/o FAN
4XG7A15878 B4P6 SR630 Intel Xeon Platinum 8276L 28C 165W 2.2GHz Processor w/o FAN
4XG7A15867 B4H7 SR630 Intel Xeon Platinum 8280 28C 205W 2.7GHz Processor w/o FAN
4XG7A15865 B4NX SR630 Intel Xeon Platinum 8280M 28C 205W 2.7GHz Processor w/o FAN
4XG7A15863 B4P5 SR630 Intel Xeon Platinum 8280L 28C 205W 2.7GHz Processor w/o FAN

* For CTO configurations, the feature code represents a processor, and fans and heatsinks are derived by the configuration tool.
** Factory-installed only; no field upgrade. Supported in the single-processor configurations only.

Configuration note: If processors with 200 W or 205 W TDP are used, or if Gold 6240Y, 6244, 6246, or 6252N processors are used, the following conditions must be met:

  • No rear HDD kit installed
  • No U.2 NVMe 10-bay backplane installed
  • No PCIe flash adapters installed
  • No GPUs installed
  • No persistent memory modules installed
  • A maximum of one supercapacitor module installed
  • ASHRAE A2 (35°C [95 °F]) only
  • The server performance might be impacted in case of a fan failure
  • No backplanes installed, or 2.5" 10-bay AnyBay backplane with up to 4 drives installed (For Gold 6240Y, 6242R, 6246R, 6248R, 6254, and 6258R processors only)

Continued support for 1st Gen Intel Xeon Scalable processors

The SR630 also continues to support the 1st Gen Intel Xeon Scalable processors (formerly codenamed "Skylake") listed in the following table.

Table 15. Long-life 1st Gen Intel Xeon Scalable processors
Part number Feature code Description
7XG7A05563 No CTO* ThinkSystem SR630 Intel Xeon Platinum 8176 28C 165W 2.1GHz Processor Option Kit
4XG7A09411 No CTO* ThinkSystem SR630 Intel Xeon Platinum 8180M 28C 205W 2.5GHz Processor Option Kit

* Only available as a field upgrade for existing customers. Not available in CTO (configure to order) configurations.

For specifications of these processors, see the Intel Xeon Scalable Processor Reference for Lenovo ThinkSystem Servers:
https://lenovopress.com/lp1262-intel-xeon-sp-processor-reference#term=SKL

Configuration note for 1st Gen processors:  For Gold 6144, 6146, and 6154 processors and Platinum 8168, 8180, and 8180M processors, the following conditions must be met:

  • No rear HDD kit installed
  • No U.2 NVMe 10-bay backplane installed
  • No PCIe flash adapters installed
  • No GPUs installed
  • A maximum of one supercap module installed
  • ASHRAE A2 (35°C, 95 °F) only
  • The server performance might be impacted in case of a fan failure
  • For Gold 6154 processor only: No backplanes installed, or 2.5" 10-bay AnyBay backplane with up to 4 drives installed

UEFI operating modes

The SR630 offers preset operating modes that affect energy consumption and performance. These modes are a collection of predefined low-level UEFI settings that simplify the task of tuning the server to suit your business and workload requirements.

The following table lists the feature codes that allow you to specify the mode you wish to preset in the factory for CTO orders.

Table 16. UEFI operating mode presets in DCSC
Feature code Description
BFYB Operating mode selection for: "Maximum Performance Mode"
BFYC Operating mode selection for: "Minimal Power Mode"
BFYD Operating mode selection for: "Efficiency Favoring Power Savings Mode"
BFYE Operating mode selection for: "Efficiency - Favoring Performance Mode"

The preset modes for the SR630 are as follows:

  • Maximum Performance Mode (feature BFYB): Achieves maximum performance but with higher power consumption and lower energy efficiency.
  • Minimal Power Mode (feature BFYC): Minimize the absolute power consumption of the system.
  • Efficiency Favoring Power Savings Mode (feature BFYD): Maximize the performance/watt efficiency with a bias towards power savings. This is the favored mode for SPECpower benchmark testing, for example.
  • Efficiency Favoring Performance Mode (feature BFYE): Maximize the performance/watt efficiency with a bias towards performance. This is the favored mode for Energy Star certification, for example.

For details about these preset modes, and all other performance and power efficiency UEFI settings offered in the SR630, see the paper "Tuning UEFI Settings for Performance and Energy Efficiency on Intel Xeon Scalable Processor-Based ThinkSystem Servers", available from https://lenovopress.lenovo.com/lp1477.

Memory

The SR630 server supports up to 12 TruDDR4 memory when one processor is installed and up to 24 DIMMs when two processors are installed. Each processor has six memory channels (two integrated memory controllers with three memory channels per memory controller), and there are two DIMMs per channel.

With 2nd Gen Xeon SP processors, the server supports memory up to 2933 MHz. With 1st Gen Xeon SP processors, the server supports memory up to 2666 MHz.

Lenovo TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned on every ThinkSystem server to maximize performance and reliability. TruDDR4 memory has a unique signature programmed into the DIMM, which enables Lenovo servers to verify whether the memory installed is qualified and supported. Lenovo qualified and supported TruDDR4 memory is covered by Lenovo warranty, and service and support provided worldwide.

The following maximum memory capacities are supported by the server with 2nd Gen Xeon SP processors (up to 2933 MHz):

  • RDIMMs: 1.5 TB (768 GB per processor)
  • 3DS RDIMMs: 3 TB (1.5 TB per processor)

The following maximum memory capacities supported by the server with 1st Gen Xeon SP processors (up to 2666 MHz):

  • RDIMMs: 768 GB (384 GB per processor)
  • LRDIMMs: 1.5 TB (768 GB per processor)
  • 3DS RDIMMs: 3 TB (1.5 GB per processor)

The following memory protection technologies are supported by the processor's integrated memory controllers:

  • ECC
  • SDDC (for x4-based memory DIMMs)
  • ADDDC (for x4-based memory DIMMs; Gold and Platinum processors only)
  • Memory mirroring
  • Memory rank sparing
  • Patrol scrubbing
  • Demand scrubbing

The following table lists memory options are supported by the server. The table also indicates which processor generation is supported for each memory option.

Table 17. Memory options
Part
number
Feature
code
Description Maximum
quantity*
Gen 1
CPU
Gen 2
CPU
RDIMMs - 2933 MHz Performance+
4X77A12184 B5N6 ThinkSystem 16GB TruDDR4 Performance+ 2933MHz (2Rx8 1.2V) RDIMM 12 / 24 No Yes
4X77A12185 B5N7 ThinkSystem 32GB TruDDR4 Performance+ 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
4X77A12186 B5N8 ThinkSystem 64GB TruDDR4 Performance+ 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
RDIMMs - 2933 MHz
4ZC7A08706 B4H1 ThinkSystem 8GB TruDDR4 2933MHz (1Rx8 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08707 B4LY ThinkSystem 16GB TruDDR4 2933MHz (1Rx4 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08708 B4H2 ThinkSystem 16GB TruDDR4 2933MHz (2Rx8 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08709 B4H3 ThinkSystem 32GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
4ZC7A08710 B4H4 ThinkSystem 64GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM 12 / 24 No Yes
3DS RDIMMs - 2933 MHz Performance+
4X77A12187 B5N9 ThinkSystem 128GB TruDDR4 Performance+ 2933MHz (4Rx4 1.2V) 3DS RDIMM 12 / 24 No Yes
3DS RDIMMs - 2933 MHz
4ZC7A15113 B587 ThinkSystem 128GB TruDDR4 2933MHz (4Rx4 1.2V) 3DS RDIMM 12 / 24 No Yes
RDIMMs - 2666 MHz
7X77A01301 AUU1 ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM 12 / 24 Yes No
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 12 / 24 Yes Yes
7X77A01303 AUNC ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM 12 / 24 Yes Yes
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 12 / 24 Yes Yes
LRDIMMs - 2666 MHz
7X77A01305 AUNE ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM 12 / 24 Yes No
3DS RDIMMs - 2666 MHz
4ZC7A08716 AUW5 ThinkSystem 64GB TruDDR4 2666MHz (4Rx4, 1.2V) 3DS RDIMM 12 / 24 No Yes
7X77A01307 AUNF ThinkSystem 128GB TruDDR4 2666 MHz (8Rx4 1.2V) 3DS RDIMM 12 / 24 Yes No

* The maximum quantity shown is with one processor / two processors.

Configuration notes:

  • All DIMMs in the server operate at the same speed, which is determined as the lowest value of:
    • DIMM rated speed (2666 MHz or 2933 MHz).
    • Memory speed supported by the specific processor (2133 MHz, 2400 MHz, 2666 MHz, or 2933 MHz).
    • Memory speed for the selected quantity of DIMMs per channel:
      • One DIMM per channel (1 DPC): 2933 MHz.
      • Two DIMMs per channel (2 DPC)
        • Performance+ DIMMs: 2933 MHz.
        • Other supported DIMMs: 2666 MHz.
    Note: Maximum memory speed can be achieved when Max performance mode is enabled in UEFI.
  • Mixing different types of memory (RDIMMs, LRDIMMs, 3DS RDIMMs) is not supported.
  • All Performance+ DIMMs in the server must be of the same type, rank, and capacity (the same part number or feature code) to operate at 2933 MHz in the configurations with two DIMMs per channel. Performance+ DIMMs cannot be mixed with other DIMMs. 
  • Mixing RDIMMs of different ranks (single- or dual-rank), DRAM chip types (x4 or x8), speeds (2666 MHz or 2933 MHz), and capacities (8 GB, 16 GB, 32 GB, or 64 GB) is supported in the independent channel mode (the default operational mode) (excluding Performance+ RDIMMs).
  • Mixing 3DS RDIMMs of different speeds (2666 MHz or 2933 MHz) and capacities (64 GB or 128 GB) is supported in the independent channel mode (excluding Performance+ 3DS RDIMMs).
  • The 128 GB Performance+ 2933 MHz 3DS RDIMMs (feature code B5N9) running at 2933 MHz with two DIMMs per channel are supported at the ambient temperature of up to 30 °C (86 °F).
  • The maximum quantity of DIMMs supported is reduced by the quantity of DC Persistent Memory Modules used in the configuration.
  • Server configurations with more than 1 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 2 TB (M-suffix) or 4.5 TB (L-suffix) per socket. Server configurations with more than 2 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 4.5 TB per socket (L-suffix).
  • For server configurations with memory protection, the following rules apply:
    • Single Device Data Correction (SDDC) works only in the independent channel mode and supports only x4-based memory DIMMs.
    • Adaptive Double Device Data Correction (ADDDC) works with x4-based memory DIMMs and requires two DIMM ranks per channel, Intel Xeon Gold or Platinum processors, and the Closed Page memory access mode.
    • If memory mirroring is used, then DIMMs must be installed in quantities of 2, 4, or 8 per processor for mirroring across two memory channels, or in quantities of 3, 6, 9, or 12 per processor for mirroring across three memory channels. Mixing two- and three-channel mirroring in the server is allowed (one processor uses two-channel mirroring, and another processor uses three-channel mirroring). All DIMMs in the server must be identical in type and size.
    • If memory rank sparing is used, then a minimum of two ranks must be installed per populated channel (a least one dual-rank or quad-rank DIMM, or two single-rank DIMMs). In rank sparing mode, one rank in each populated channel is reserved as spare memory for other ranks on the same channel. All DIMMs in the server must be identical in type and size.
    • SDDC, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on the server.
    • In the configurations with DCPMMs, memory mirroring is supported only in the App Direct mode (other DCPMM modes do not support memory mirroring) and applies only to the RDIMMs or 3DS RDIMMs (DCPMMs are not mirrored). Memory sparing is not supported in the configurations with DCPMMs.

Persistent memory

Intel Optane persistent memory is an innovative technology that delivers a unique combination of affordable large memory capacity and persistence (non-volatility). The persistent memory technology can help boost the performance of data-intensive applications, such as in-memory analytics, databases, content delivery networks, and high performance computing (HPC), as well as deliver consistent service levels at scale with higher virtual machine and container density.

2nd Gen processors only: Persistent Memory is only supported with 2nd Generation Intel Xeon SP processors. Not supported with 1st Generation processors.

The SR630 server supports up to six TruDDR4 DC Persistent Memory Modules (DCPMMs) when one processor is installed and up to 12 DCPMMs when two processors are installed (up to one DCPMM per processor's memory channel) for a total of up to 6 TB of persistent memory capacity. The DCPMMs are installed in the same memory DIMM slots on the system board that are used for installing RDIMMs or 3DS RDIMMs.

The DCPMMs support the following modes of operation:

  • Memory Mode

    Memory Mode seamlessly brings large memory capacity at affordable cost points to legacy applications. In this mode, DCPMMs provide volatile memory that behaves much like traditional RDIMMs or 3DS RDIMMs (the data will not be saved in case of a power loss) and is transparent to the operating system and applications. DCPMMs provide memory capacity and RDIMMs or 3DS RDIMMs provide cache memory that is managed by the processor's memory controller. The total memory capacity that is seen by the operating system is the capacity of the DCPMMs; the capacity of the RDIMMs or 3DS RDIMMs is hidden and does not appear as a memory resource in the operating system. This mode is considered particularly suited for virtualized database deployments and big-data analytics applications.

  • App Direct Mode

    App Direct Mode brings persistency to the data and structures (the data will be saved in case of a power loss). This mode requires operating system and application awareness of two types of system memory: Persistent (DCPMMs) and DRAM (RDIMMs or 3DS RDIMMs). The total memory capacity that is seen by the operating system includes the capacity of the DCPMMs and RDIMMs or 3DS RDIMMs. This mode is considered particularly suited for in-memory databases, in-memory analytics frameworks, and ultrafast storage applications.

  • Mixed Memory Mode

    Mixed Memory Mode is a combination of Memory Mode and App Direct Mode, where a portion of the capacity of the DCPMMs is used for the Memory Mode operations, and the remaining capacity of the DCPMMs is used for the App Direct Mode operations.

The following memory protection technologies are supported by the DCPMM's onboard memory controllers:

  • ECC
  • SDDC
  • DDDC
  • Patrol scrubbing
  • Demand scrubbing

The following table lists DCPMM options available for the SR630 server.

Table 18. DCPMM options
Part
number
Feature
code
Description Maximum
quantity*
4ZC7A15110 B4LV ThinkSystem 128GB TruDDR4 2666MHz (1.2V) Intel Optane DC Persistent Memory 6 / 12
4ZC7A15111 B4LW ThinkSystem 256GB TruDDR4 2666MHz (1.2V) Intel Optane DC Persistent Memory 6 / 12
4ZC7A15112 B4LX ThinkSystem 512GB TruDDR4 2666MHz (1.2V) Intel Optane DC Persistent Memory 6 / 12

* The maximum quantity shown is with one processor / two processors.

Configuration notes:

  • All DCPMMs in the server must be of the same capacity (the same part number or feature code).
  • The RDIMMs or 3DS RDIMMs are required in the configurations with DCPMMs, and all RDIMMs or 3DS RDIMMs must be of the same type, rank, and capacity (the same part number or feature code).
  • The DCPMMs cannot be mixed with the 8GB TruDDR4 2933 MHz RDIMM (4ZC7A08706).
  • For Mixed Memory Mode, the volatile (Memory) portion of the total capacity of DCPMMs is configured in increments of 32 GB multiplied by the number of DCPMMs in the server, and the remaining capacity is allocated to the persistent (App Direct) portion. The ratio of the total capacity of RDIMMs or 3DS RDIMMs to the total capacity of the volatile portion of DCPMMs should be between 1:2 and 1:16.
  • Server configurations with more than 1 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 2 TB (M-suffix) or 4.5 TB (L-suffix) per socket. Server configurations with more than 2 TB of memory capacity per socket (including DCPMMs and RDIMMs or 3DS RDIMMs) require processors that support up to 4.5 TB per socket (L-suffix).
  • The DCPMMs are not supported in the following configurations:
    • Processors of 200 W or 205 W TDP, or Gold 6240Y, 6244, 6246, or 6252N processors installed
    • GPU adapters installed
    • Mellanox Innova-2 adapters installed

For more information, including supported combinations of DIMMs and Persistent Memory, refer to the Intel Optane Persistent Memory 100 Series Product Guide:
https://lenovopress.com/lp1066-intel-optane-persistent-memory-100-series

Internal storage

Topics in this section:

Configurations

The SR630 server supports the following internal drive bay configurations:

  1. Up to 6 SAS/SATA hot-swap drive bays: 4x 3.5" (front) + 2x 2.5" (rear)
  2. 4 LFF AnyBay hot-swap drive bays: 4x 3.5" (front)
  3. Up to 10 SFF SAS/SATA hot-swap drive bays: 8x 2.5" (front) + 2x 2.5" (rear)
  4. Up to 12 SFF hot-swap drive bays:
    6x 2.5" SAS/SATA & 4x 2.5" AnyBay (front) + 2x 2.5" SAS/SATA (rear)
  5. 10 SFF U.2 NVMe PCIe SSD hot-swap drive bays

In addition, the SR630 server models can be configured with one or two internal M.2 SATA SSDs. The server also supports configurations without drive bays.

The following figure shows the internal drive bay configurations.

Internal drive configurations
Figure 7. Internal drive bay configurations

Backplanes

The following table lists the internal storage options for the server for configure-to-order builds.

Field upgrades: For field upgrades to add drive backplanes, see the Field upgrades section

Table 19. Internal storage options
Feature
code
Description Drive bays Maximum
quantity
3.5-inch front backplanes
AUW8 ThinkSystem 3.5" SATA/SAS 4-Bay Backplane 4x SAS/SATA 1
B0WJ ThinkSystem SR630 3.5" Anybay 4-Bay Backplane 4x NVMe/SAS/SATA 1
2.5-inch front backplanes
AUWB ThinkSystem SR530/SR630/SR570 2.5" SATA/SAS 8-Bay Backplane 8x SAS/SATA 1
AUW9 ThinkSystem 1U 10x2.5" (6x SAS/SATA 4x AnyBay) Backplane 6x SAS/SATA drives +
4x NVMe/SAS/SATA
1
BMNM ThinkSystem SR630 2.5" U.2 10-Bay Backplane Kit v2 10x NVMe 1
AVKF ThinkSystem SR630 2.5" U.2 10-Bay Backplane Kit 10x NVMe 1
BQBC ThinkSystem SR630 2.5" U.2 8-Bay Backplane Kit v2 8x NVMe 1
BQBB ThinkSystem SR630 2.5" U.2 8-Bay Backplane Kit 8x NVMe 1
Rear backplanes
BMXG ThinkSystem SR630 Rear HDD/SSD Kit v2 2x SAS/SATA 1
AUWJ ThinkSystem SR630 Rear HDD Kit 2x SAS/SATA 1

Configuration notes:

  • Lenovo AnyBay allows a choice of drive interface types in the same drive bay: SAS drives, SATA drives, or U.2 NVMe PCIe drives.
  • U.2 NVMe PCIe SSDs in the AnyBay drive bays require either the second processor (enables the onboard NVMe controller) or the 1610-4P NVMe Switch Adapter to be installed. The 1610-4P NVMe Switch Adapter connected to the AnyBay drive bays is supported only in the configurations with one processor.
  • Models with 10x 2.5-inch drive bays (6x SAS/SATA + 4x AnyBay) and an 8-port SAS RAID controller or HBA support only NVMe drives in the AnyBay drive bays.

Supported drive bay combinations

The following tables list supported internal storage configurations with the SAS/SATA and AnyBay backplanes.

Table 20. Internal storage configurations: 3.5-inch front drive bays
Drive bay configuration Backplane kit type and quantity Storage controller type and quantity*
4x 3.5" SATA/SAS
4x 3.5" AnyBay
2x 2.5" Rear HDD
4x 3.5" chassis (Feature code AUW2)
4x 3.5-in. SAS/SATA hot-swap (front) 1 0 0 1x RAID 8i or HBA 8i (4)
4x 3.5-in. SAS/SATA hot-swap (front) +
2x 2.5-in. SAS/SATA hot-swap (rear)
1 0 1 1x RAID 8i or HBA 8i (6)
4x 3.5-in. AnyBay hot-swap (front) 0 1 0 1x RAID 8i or HBA 8i (4) + NVMe (4)**

* The number in brackets (x) specifies the quantity of drive bays connected to each of the controllers.
** The 1610-4P NVMe Switch Adapter in the configurations with one processor, or the onboard NVMe controller in the configurations with two processors.

Table 21. Internal storage configurations: 2.5-inch front drive bays
Drive bay configuration Backplane kit type and quantity Storage controller type and quantity*
8x 2.5" SATA/SAS
10x 2.5" AnyBay
8x U.2 NVMe
10x U.2 NVMe
2x 2.5" Rear HDD
8x 2.5" chassis (Feature code AUW0)
8x 2.5-in. SAS/SATA hot-swap (front) 1 0 0 0 0 1x RAID 8i or HBA 8i (8)
1x RAID 16i (8)
8x 2.5-in. SAS/SATA hot-swap (front) +
2x 2.5-in. SAS/SATA hot-swap (rear)
1 0 0 0 1 1x RAID 16i or HBA 16i (10)
10x 2.5" chassis (Feature code AUW1)
4x 2.5-in. AnyBay (NVMe only)
hot-swap (front)
0 1 0 0 0 Onboard NVMe (4)**
6x 2.5-in. SAS/SATA +
4x 2.5-in. AnyBay 
hot-swap (front)
0 1 0 0 0 1x RAID 16i or HBA 16i (10) + Onboard NVMe (4)**
6x 2.5-in. SAS/SATA +
4x 2.5-in. AnyBay (NVMe only)
hot-swap (front)
0 1 0 0 0 1x RAID 8i or HBA 8i (6) + Onboard NVMe (4)**
1x RAID 8i or HBA 8i (6) + 1x 1610-4P NVMe (4)^
1x RAID 16i or HBA 16i (6) + 1x 1610-4P NVMe (4)^
6x 2.5-in. SAS/SATA +
4x 2.5-in. AnyBay 
hot-swap (front) +
2x 2.5-in. SAS/SATA hot-swap (rear)
0 1 0 0 1 1x RAID 16i or HBA 16i (12) + Onboard NVMe (4)**
10x 2.5-in. U.2 NVMe
(8x NVMe drives only) hot-swap (front)
0 0 1 0 0 Onboard NVMe (4)** + 1x 1610-4P/810-4P (4)
Onboard NVMe (4)** + 2x 810-4P (2+2)
1x 1611-8P (8)
10x 2.5-in. U.2 NVMe hot-swap (front) 0 0 0 1 0 Onboard NVMe (4)** + 1x 1610-4P (4) + 1x 810-4P (2)
Onboard NVMe (4)** + 2x 1610-4P (4+2)
Onboard NVMe (4)** + 1x 1611-8P (6)

* The number in brackets (x) specifies the quantity of drive bays connected to each of the controllers.
** The onboard NVMe controller requires the second processors to be installed.
^ The 1610-4P NVMe Switch Adapter connected to the AnyBay drive bays is supported only in the configurations with one processor. CTO only, not available as a field upgrade.

Field upgrades

The following table lists the backplane options that can be installed as field upgrades.

Use with X40 adapters: These backplane kits in the table below include SAS/SATA cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you are adding or upgrading to RAID 940 adapters or 440 HBAs (collectively called X40 adapters), you will need to also order an X40 cable kit. See the Cable kits for 440 HBAs and RAID 940 adapters section for details.

Use with the 1611-8P adapter: AnyBay and NVMe backplane kits in the table below include NVMe cables for use with 1610-4P or 810-4P NVMe adapters. If you are adding or upgrading to the 1611-8P NVMe adapter, you will need to also order 1611-8P Cable Kit. See the Cable kit for the 1611-8P adapter section for details.

Table 22. Drive bay field upgrades
Part number Description Maximum quantity
Front drive bay backplanes - field upgrade kits
4XH7A80455 ThinkSystem SR530/SR630 2.5" SATA/SAS 8-Bay Backplane Kit v2 1
7XH7A05896 ThinkSystem SR530/SR630 2.5" SATA/SAS 8-Bay Backplane Kit 1
4XH7A80452 ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay Backplane Upgrade Kit v2 1
4XH7A08768 ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay Backplane Upgrade Kit 1
4XH7A80451 ThinkSystem SR630 2.5" U.2 10-Bay Backplane Kit v2 1
4XH7A08766 ThinkSystem SR630 2.5" U.2 10-Bay Backplane Kit 1
Rear drive bays - field upgrade kits
4XH7A80454 ThinkSystem SR630 Rear HDD/SSD Kit v2 1
7XH7A06252 ThinkSystem SR630 Rear HDD/SSD Kit 1

Configuration notes:

  • The backplane upgrade kits include drive backplanes and required signal cables, power cables, and drive bay fillers; storage controllers are not included.
  • Models without any drive bays that are based on the 8x 2.5" chassis (feature code AUW0) support adding drive bays by using the 2.5" 8-drive backplane kit (7XH7A05896 or 4XH7A80455).
  • Models without any drive bays that are based on the 10x 2.5" chassis (feature code AUW1) support adding drive bays by using the 2.5" 10-bay AnyBay backplane kit (4XH7A08768 or 4XH7A80452) or 2.5" U.2 10-bay backplane kit (4XH7A08766 or 4XH7A80451).
  • Models with 10x 2.5-inch drive bays (6x SAS/SATA + 4x AnyBay) can be upgraded to all NVMe configuration by using the 2.5" U.2 10-Bay Backplane Kit (4XH7A08766 or 4XH7A80451). The kit includes a backplane, cables, and drive fillers. NVMe Switch Adapters are not included in the kit; two NVMe Switch Adapters are required for the 10x 2.5" U.2 NVMe configuration.
  • The 2.5" Rear HDD Kit is installed in place of the PCIe Riser Card 1; PCIe slots 1 and 2 are not present.
  • The 2.5" Rear HDD Kit is supported only with the processors of up to 125 W TDP.
  • U.2 NVMe PCIe SSDs in the AnyBay drive bays require either the second processor (enables the onboard NVMe controller) or the 1610-4P NVMe Switch Adapter to be installed. The 1610-4P NVMe Switch Adapter connected to the AnyBay drive bays is supported only in the configurations with one processor.
  • Models with 10x 2.5-inch drive bays (6x SAS/SATA + 4x AnyBay) and an 8-port SAS RAID controller or HBA support only NVMe drives in the AnyBay drive bays.

Cable kits for 440 HBAs and RAID 940 adapters

The backplane kits listed in the Drive bay field upgrades table include cables for use with the onboard SATA controller or with RAID 930, 730, 530 adapters and 430 HBAs (collectively called X30 adapters). If you wish to use the backplane kits with RAID 940 adapters or 440 HBAs (collectively called X40 adapters), then you will also need to order an additional X40 cable kit to use instead of the cables in the backplane kit.

Tip: When adding an X40 adapter, you will order both the backplane kit and the relevant X40 cable kit, however the SAS/SATA data cable(s) in the backplane kit will not be used.

Table 23. Cable kits for 440 HBAs and RAID 940 adapters
Backplane kits with X30 cables X40 cable kits also needed
4XH7A80455 ThinkSystem SR530/SR630 2.5" SATA/SAS 8-Bay Backplane Kit v2 4XH7A61096 ThinkSystem SR530/SR570/SR630 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
7XH7A05896 ThinkSystem SR530/SR630 2.5" SATA/SAS 8-Bay Backplane Kit 4XH7A61096 ThinkSystem SR530/SR570/SR630 2.5" SAS/SATA 8-Bay X40 RAID Cable Kit
4XH7A80452 ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay Backplane Upgrade Kit v2 4XH7A61101 ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay X40 RAID Cable Kit
4XH7A08768 ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay Backplane Upgrade Kit 4XH7A61101 ThinkSystem SR570/SR630 2.5" AnyBay 10-Bay X40 RAID Cable Kit
4XH7A80451 ThinkSystem SR630 2.5" U.2 10-Bay Backplane Kit v2 None Not needed - NVMe only
4XH7A08766 ThinkSystem SR630 2.5" U.2 10-Bay Backplane Kit None Not needed - NVMe only
4XH7A80454 ThinkSystem SR630 Rear HDD/SSD Kit v2 4XH7A61110 ThinkSystem SR590/SR630/SR650 SAS/SATA 2-Bay Rear BP X40 RAID Cable Kit
7XH7A06252 ThinkSystem SR630 Rear HDD/SSD Kit 4XH7A61110 ThinkSystem SR590/SR630/SR650 SAS/SATA 2-Bay Rear BP X40 RAID Cable Kit

Cable kit for the 1611-8P adapter

The backplane kit part numbers listed in the Drive bay field upgrades table that include NVMe connections (that is, NVMe backplanes and AnyBay backplanes) only include cables for use with 1610-4P or 810-4P NVMe adapters. If you wish to use these backplane kits with the 1611-8P NVMe adapter, then you will also need to order an additional cable kit to use instead of the cables in the backplane kit.

Tip: When adding an 1611-8P adapter, you will order both the backplane kit and the 1611-8P cable kit, however the NVMe data cables in the backplane kit will not be used.

Table 24. Cable kit for 1611-8P adapter
Part number Description
4X97A83643 ThinkSystem SR630 1611-8P NVMe Switch Adapter Cable Kit

RAID flash power module (supercap) support

ThinkSystem RAID 930, 940, 9350 and 730-8i 2GB adapters all include a RAID flash power module (supercap). If you plan to install one of these adapters as a field upgrade, then may also need to order a Supercap Holder kit or a replacement server air baffle to mount the power module. For CTO orders, the components in the installation kit are automatically derived when you select the RAID adapter.

The server supports one or two RAID adapters (internal or external) with supercaps, however there are three possible locations for the supercaps to be mounted. The locations of the supercaps depends on the front drive bays (2.5-inch or 3.5-inch) and the size of the processor heatsinks (which in turn determines if the air baffle is installed). Details are summarized in the following table. Location references are shown in the figure below.

Note: Some configurations do not support a supercap-attached RAID adapter as shown in the table.

Table 25. Supercap support
Front drive
configuration
Processor heatsinks Number of adapters
& supercaps
Location of supercaps
2.5-inch Standard 2
  1. Front of server behind operator panel ❸ (if present)
  2. Mounted on air baffle ❶
  3. Mounted on air baffle ❷ (if no holder installed in ❸)
High Performance (no air baffle installed) 1
  1. Front of server behind operator panel ❸
3.5-inch Standard 2
  1. Mounted on air baffle ❶
  2. Mounted on air baffle ❷
High Performance (no air baffle installed) 0 Not supported

The locations where supercaps are installed is shown in the following figure.

Location of the supercaps in the SR630
Figure 8. Location of the supercaps in the SR630

If the server does not include a supercap holder in position ❸, order the holder using part number 4M17A61348.

If one of the following RAID adapters is purchased as a field upgrade, the system air duct (air baffle) will need to be replaced with a new one to accommodate the supercap that ships with the adapter. The original air duct won't physically accomodate the supercap of these adapters.

  • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter, 4Y37A72483
  • ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter, 4Y37A72485

Tip: If your server was built before December 2021 or was configured with base feature codes AUW0, AUW1 or AUW2, then you have original air duct, part SM27A03474, and you will need to order a replacement air duct. If you server was configured with newer "v2" base feature codes BNPN, BNPQ or BNPP, then you have the newer air duct, part SM27A99423 and no air duct replacement is necessary.

Ordering information for the Supercap Holder Kit and the replacement air duct are listed in the following table.

Table 26. Supercap installation field upgrades
Part number Feature code Description Maximum
supported
4M17A61304 AURN ThinkSystem V3 1U Supercap Holder Kit
(For use in position ❸ at the front of the server)
1
4M17A61348 BNZ0 ThinkSystem SR630 Air Duct Kit v2
(Enables ❶ and ❷ for use with the 9350-8i or 9350-16i adapters)
1

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 27. M.2 components
Part number Feature code Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

SED encryption key management with SKLM

The server supports self-encrypting drives (SEDs) as listed in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution. A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server.

The following table lists the part numbers and feature codes for the upgrades.

Table 28. FoD upgrades for SKLM support
Part number Feature code Description
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00D9999 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00FP649 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S

The IBM Security Key Lifecycle Manager software is available from Lenovo using the ordering information listed in the following table.

Table 29. IBM Security Key Lifecycle Manager licenses
Part number Description
7S0A007FWW IBM Security Key Lifecycle Manager Basic Edition Install License + SW Subscription & Support 12 Months
7S0A007HWW IBM Security Key Lifecycle Manager For Raw Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007KWW IBM Security Key Lifecycle Manager For Raw Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007MWW IBM Security Key Lifecycle Manager For Usable Decimal Terabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months
7S0A007PWW IBM Security Key Lifecycle Manager For Usable Decimal Petabyte Storage Resource Value Unit License + SW Subscription & Support 12 Months

Controllers for internal storage

The following table lists the storage controllers and options for internal storage of the SR630 server.

Onboard SATA: The SR630 does not offer onboard SATA functionality.

Table 30. RAID controllers and HBAs for internal storage
Part number Feature code Description Maximum quantity I/O slots
supported
12 Gb SAS/SATA RAID controllers - 8-port adapters
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 1 4, 1
4Y37A78834 BMFT ThinkSystem RAID 540-8i PCIe Gen4 12Gb Adapter 1 1
4Y37A72482 BJHK ThinkSystem RAID 5350-8i PCIe 12Gb Adapter 1 1
7Y37A01083 AUNH ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 1 4, 1
4Y37A09722 B4RQ ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter 1 4, 1
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 1 4, 1
4Y37A72483† BJHL† ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter 1 1
4Y37A09728 B8NY ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter 1 1
12 Gb SAS/SATA RAID controllers - 16-port adapters
4Y37A09727 B6CE ThinkSystem RAID 530-16i PCIe 12Gb Adapter 1 4, 1
4Y37A78835 BNAX ThinkSystem RAID 540-16i PCIe Gen4 12Gb Adapter 1 1
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 1 4, 1
4Y37A72485† BJHN† ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter 1 1
4Y37A09721 B31E ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter 1 4, 1
4Y37A78600 BM35 ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter 1 1
4Y37A09730 B8NZ ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter 1 1
12 Gb SAS/SATA non-RAID HBAs
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 1 4, 1
4Y37A72480 BJHH ThinkSystem 4350-8i SAS/SATA 12Gb HBA 1 1
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 1 4, 1
4Y37A72481 BJHJ ThinkSystem 4350-16i SAS/SATA 12Gb HBA 1 1
4Y37A78601 BM51 ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA 1 1
4Y37A78602 BM50 ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA 1 1
NVMe PCIe interfaces
None B9X7 Intel VROC (VMD NVMe RAID) Intel SSD Only (Standard) 1 Not applicable
4L47A39164 B96G Intel VROC (VMD NVMe RAID) Premium
(license upgrade - to enable RAID support for non-Intel NVMe SSDs)
1 Not applicable
4Y37A09737 B8P5 ThinkSystem 1611-8P PCIe Gen4 Switch Adapter 1 2*
7Y37A01081 AUV2 ThinkSystem 1610-4P NVMe Switch Adapter 2 2, 3*
4Y37A09719 B22D ThinkSystem 810-4P NVMe Switch Adapter 2 4, 1

* Requires a PCIe x16 riser card.
† Field upgrades to add this adapter may also require a replacement system air duct. See the RAID flash power module (supercap) support section for details. CTO orders that include this adapter must have base BNPS or BNPR selected. See the Models section for information.

For a comparison of the functions of the supported storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288-thinksystem-raid-adapter-and-hba-reference#sr630-support=SR630

Configuration notes:

  • Low profile SAS RAID controllers and HBAs for internal storage are supported in the dedicated PCIe x8 slot 4 on the system board. If a full-height GPU adapter is installed, the internal slot for a storage controller cannot be used; the storage controller should be installed in the PCIe slot 1.
  • The 1610-4P and 1611-8P NVMe Switch Adapters require PCIe x16 slots.
  • The 810-4P NVMe Switch Adapters are supported in the dedicated PCIe x8 slot 4 on the system board and a low-profile PCIe x8 slot supplied by the PCIe Riser Card 1.
  • The total quantity of the NVMe Switch Adapters in the server must not exceed 2.
  • Configurations using onboard NVMe and NVMe switch adapters support RAID using Intel VROC NVMe RAID as described in the Intel VROC onboard RAID section.
  • The onboard NVMe interface provides 4x PCIe 3.0 x4 ports for connectivity to U.2 NVMe PCIe SSDs in the AnyBay drive bays, and it requires the second processor to be installed.
  • In the configurations with one processor, the 1610-4P NVMe Switch Adapter provides 4x PCIe 3.0 x4 ports for connectivity to U.2 NVMe PCIe SSDs in the AnyBay drive bays, and it is supported in the PCIe x16 slot 2 supplied by the x8/x16 Riser Card 1.
  • In the configurations without GPU installed, the total quantity of the RAID 730-8i 2GB, RAID 930-8i, RAID 930-16i, and RAID 930-8e controllers in the server must not exceed 2 (up to 2 supercapacitors can be mounted in the server).
  • In the configurations with GPU installed, the total quantity of the RAID 730-8i 2GB, RAID 930-8i, RAID 930-16i, and RAID 930-8e controllers in the server must not exceed 1 (the storage controller can be installed only in the PCIe slot 1; the PCIe slots 3 and 4 cannot be used if the GPU adapter is installed).
  • In the configurations with the RAID 730-8i 2GB controller, the RAID 930-8e controller cannot be used.
  • For 10x U.2 NVMe configurations, the onboard NVMe interface and two NVMe Switch Adapters provide connectivity with PCIe 3.0 x4 links to each of the U.2 NVMe PCIe SSDs. The 1610-4P NVMe Switch Adapter has a PCIe 3.0 x16 host interface, and the 810-4P NVMe Switch Adapter has a PCIe 3.0 x8 host interface.
  • E810 Ethernet and X350 RAID/HBAs: The use of both an Intel E810 network adapter and an X350 HBA/RAID adapter (9350, 5350 and 4350) is currently not supported in ThinkSystem servers. For details see Support Tip HT513226. Planned support for this combination of adapters is 2Q/2024.

Intel VROC onboard RAID

Intel VROC (Virtual RAID on CPU) is a feature of the Intel processor that enables RAID support.

On the SR630, Intel VROC provides RAID functions for the onboard NVMe controller (Intel VROC NVMe RAID).

VROC NVMe RAID offers RAID support for any NVMe drives directly connected to the ports on the server's system board or via adapters such as NVMe retimers or NVMe switch adapters. On the SR630, RAID levels implemented are based on the VROC feature selected as indicated in the following table. RAID 1 is limited to 2 drives per array, and RAID 10 is limited to 4 drives per array. Hot-spare functionality is also supported.

Performance tip: For best performance with VROC NVMe RAID, the drives in an array should all be connected to the same processor. Spanning processors is possible however performance will be unpredictable and should be evaluated based on your workload.

The SR630 supports the VROC NVMe RAID offerings listed in the following table. The VROC Intel SSD Only offering only supports RAID on Intel branded NVMe SSDs; non-Intel branded NVMe SSDs cannot be configured in a RAID array.

Table 31. Intel VROC NVMe RAID ordering information and feature support
Part
number
Feature
code
Description Intel
NVMe SSDs
Non-Intel
NVMe SSDs
RAID 0 RAID 1 RAID 10 RAID 5
CTO only B9X7 Intel VROC (VMD NVMe RAID) Intel SSD Only Yes No Yes Yes Yes Yes
4L47A39164 B96G Intel VROC (VMD NVMe RAID) Premium Yes Yes Yes Yes Yes Yes

Configuration notes:

  • If a feature code is ordered in a CTO build, the VROC functionality is enabled in the factory. For field upgrades, order a part number and it will be fulfilled as a Feature on Demand (FoD) license which can then be activated via the XCC management processor user interface.

Virtualization support: Virtualization support for Intel VROC is as follows:

  • VROC (VMD) NVMe RAID: VROC (VMD) NVMe RAID is supported by ESXi, KVM, Xen, and Hyper-V. ESXi support is limited to RAID 1 only; other RAID levels are not supported. Windows and Linux OSes support VROC RAID NVMe, both for host boot functions and for guest OS function, and RAID-0, 1, 5, and 10 are supported. On ESXi, VROC is supported with both boot and data drives.

Internal drive options

The following tables list the drive options for internal storage of the server.

M.2 drives:

M.2 drive support: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

SED support: The tables include a column to indicate which drives support SED encryption. The encryption functionality can be disabled if needed. Note: Not all SED-enabled drives have "SED" in the description.

PCIe 4.0 NVMe drive support: When installed in this server, PCIe 4.0 NVMe drives will operate at PCIe 3.0 speeds.

Table 32. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 12
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD No 12
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD No 12
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 12
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 12
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED Support 12
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED Support 12
7XB7A00033 B0YX ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD SED Support 12
7XB7A00070 B0YV ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD FIPS Support 12
2.5-inch hot-swap SED HDDs - 12 Gb NL SAS
7XB7A00064 B0YM ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 12
Table 33. 2.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 12
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD No 12
Table 34. 2.5-inch hot-swap 24 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A80340 BNW8 ThinkSystem 2.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD Support 12
4XB7A80341 BNW9 ThinkSystem 2.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD Support 12
4XB7A80342 BNW6 ThinkSystem 2.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD Support 12
4XB7A80343 BP3K ThinkSystem 2.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD Support 12
2.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A80318 BNWC ThinkSystem 2.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80319 BNWE ThinkSystem 2.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80320 BNWF ThinkSystem 2.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80321 BP3E ThinkSystem 2.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80322 BP3J ThinkSystem 2.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD Support 12
4XB7A80323 BP3D ThinkSystem 2.5" PM1653 30.72TB Read Intensive SAS 24Gb HS SSD Support 12
Table 35. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD)
4XB7A83214 BR10 ThinkSystem 2.5" Nytro 3750 400GB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A83215 BR0Z ThinkSystem 2.5" Nytro 3750 800GB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A83216 BR0Y ThinkSystem 2.5" Nytro 3750 1.6TB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A83217 BR0X ThinkSystem 2.5" Nytro 3750 3.2TB Write Intensive SAS 12Gb HS SSD Support 12
4XB7A70006 BG07 ThinkSystem 2.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A70005 BG06 ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A70007 BFZZ ThinkSystem 2.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD SED Support 12
4XB7A70004 BG05 ThinkSystem 2.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A70003 BG04 ThinkSystem 2.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10219 B4Y4 ThinkSystem 2.5" SS530 400GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10230 B4Y5 ThinkSystem 2.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10231 B4Y6 ThinkSystem 2.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD No 12
4XB7A10232 B4Y7 ThinkSystem 2.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD No 12
7N47A00124 AUMG ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD No 12
7N47A00125 AUMH ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD No 12
7N47A00126 AVRB ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD No 12
7SD7A05754 B11P ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS Support 12
7SD7A05753 B11Q ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS Support 12
7SD7A05752 B11R ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS Support 12
2.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17062 B8HU ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A17063 B8J4 ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A17064 B8JD ThinkSystem 2.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A17065 B8JA ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A13653 B4A0 ThinkSystem 2.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A13654 B4A1 ThinkSystem 2.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 12
4XB7A13655 B4A2 ThinkSystem 2.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 12
7N47A00117 AUMC ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD No 12
7N47A00118 AUMD ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD No 12
7N47A00119 AVRG ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 12
7N47A00120 AVRJ ThinkSystem 2.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 12
2.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A38175 B91A ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A38176 B91B ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A17054 B91C ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A17055 B91D ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A17056 BC4R ThinkSystem 2.5" PM1643a 15.36TB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A17168 B6TL ThinkSystem 2.5" PM1643 960GB Entry SAS 12Gb Hot Swap SSD No 12
4XB7A13645 B4A7 ThinkSystem 2.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD No 12
4XB7A13646 B4A6 ThinkSystem 2.5" PM1643 7.68TB Capacity SAS 12Gb Hot Swap SSD No 12
7N47A00121 AUMK ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD No 12
7N47A00122 AUML ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD No 12
7N47A00123 B116 ThinkSystem 2.5" PM1633a 15.36TB Capacity SAS 12Gb Hot Swap SSD No 12
Table 36. 2.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A82289 BQ21 ThinkSystem 2.5" 5400 MAX 480GB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A82290 BQ24 ThinkSystem 2.5" 5400 MAX 960GB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A82291 BQ22 ThinkSystem 2.5" 5400 MAX 1.92TB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A82292 BQ23 ThinkSystem 2.5" 5400 MAX 3.84TB Mixed Use SATA 6Gb HS SSD Support 12
4XB7A17125 BA7Q ThinkSystem 2.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17126 BA4T ThinkSystem 2.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17127 BA4U ThinkSystem 2.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17128 BK7L ThinkSystem 2.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A17087 B8J1 ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A17088 B8HY ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A17089 B8J6 ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A13972 BNEW ThinkSystem 2.5" 5300 960GB  Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A17090 B8JE ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A38193 B93K ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A17091 B8J7 ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A64222 BEMB ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A13633 B49L ThinkSystem 2.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13634 B49M ThinkSystem 2.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13635 B49N ThinkSystem 2.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13636 B49P ThinkSystem 2.5" S4610 1.92TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A13637 B49Q ThinkSystem 2.5" S4610 3.84TB Mixed Use SATA 6Gb HS SSD No 12
4XB7A10237 B488 ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A10238 B489 ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A10239 B48A ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A14062 B6K1 ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A10240 B48B ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A14063 B6K0 ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A13981 B93J ThinkSystem 2.5" 5200 (Max) 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
4XB7A10241 B48C ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 12
4XB7A13982 B81X ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD SED Support 12
7SD7A05723 B0ZP ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05722 B0ZQ ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05721 B0ZR ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05720 B0ZS ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05765 B10W ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05764 B10X ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05763 B10Y ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05762 B10Z ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 12
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 12
2.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A82258 BQ1Q ThinkSystem 2.5" 5400 PRO 240GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82259 BQ1P ThinkSystem 2.5" 5400 PRO 480GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82260 BQ1R ThinkSystem 2.5" 5400 PRO 960GB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82261 BQ1X ThinkSystem 2.5" 5400 PRO 1.92TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82262 BQ1S ThinkSystem 2.5" 5400 PRO 3.84TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A82263 BQ1T ThinkSystem 2.5" 5400 PRO 7.68TB Read Intensive SATA 6Gb HS SSD Support 12
4XB7A72438 BM8B ThinkSystem 2.5" PM893 480GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72439 BM8A ThinkSystem 2.5" PM893 960GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72440 BM89 ThinkSystem 2.5" PM893 1.92TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72441 BM88 ThinkSystem 2.5" PM893 3.84TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A72442 BM87 ThinkSystem 2.5" PM893 7.68TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17072 B99D ThinkSystem 2.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17101 BA7G ThinkSystem 2.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17102 BA7H ThinkSystem 2.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17103 BA7J ThinkSystem 2.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17104 BK77 ThinkSystem 2.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A17105 BK78 ThinkSystem 2.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A38271 BCTC ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38272 BCTD ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38273 BCTE ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38274 BCTF ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38275 BCTG ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17075 B8HV ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17076 B8JM ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17077 B8HP ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38141 BE29 ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD SED Support 12
4XB7A17078 B8J5 ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A17079 B8JP ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38191 B93L ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD SED Support 12
4XB7A17080 B8J2 ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A38192 B93M ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD SED Support 12
4XB7A38185 B9AC ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A38144 B7EW ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A38145 B7EX ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A38146 B7EY ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD No 12
4XB7A10247 B498 ThinkSystem 2.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A10248 B499 ThinkSystem 2.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A10249 B49A ThinkSystem 2.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 12
4XB7A13622 B49B ThinkSystem 2.5" S4510 1.92TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A13623 B49C ThinkSystem 2.5" S4510 3.84TB Read Intensive SATA 6Gb HS SSD No 12
4XB7A10195 B34H ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10196 B34J ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10197 B34K ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10198 B34L ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10199 B34M ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10200 B4D2 ThinkSystem 2.5" PM883 7.68TB Entry SATA 6Gb Hot Swap SSD No 12
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD No 12
7SD7A05741 B0YZ ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD No 12
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD No 12
7SD7A05739 B0Z1 ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
7SD7A05738 B0Z2 ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD No 12
7N47A00112 AUM9 ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD No 12
7N47A00113 AVCZ ThinkSystem 2.5" PM863a 960GB Entry SATA 6Gb Hot Swap SSD No 12
7N47A00114 AVRC ThinkSystem 2.5" PM863a 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A13966 B4G8 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD SED Support 12
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10155 B2X4 ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10156 B2X5 ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A10157 B2X6 ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A08502 B10N ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A08503 B10P ThinkSystem 2.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A08504 B10Q ThinkSystem 2.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD No 12
4XB7A08505 B10R ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD No 12
7N47A00099 AUM8 ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD No 12
7N47A00100 AUUZ ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD No 12
Table 37. 2.5-inch hot-swap PCIe 4.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17129 BNEG ThinkSystem 2.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A17130 BNEH ThinkSystem 2.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A17133 BNEZ ThinkSystem 2.5" U.2 P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A17152 BCFV ThinkSystem 2.5" U.2 P5600 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 10
4XB7A17153 BCFR ThinkSystem 2.5" U.2 P5600 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 10
4XB7A17154 BCFS ThinkSystem 2.5" U.2 P5600 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 10
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A79639 BNF1 ThinkSystem 2.5" U.3 7450 MAX 800GB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A13967 BNEJ ThinkSystem 2.5" U.3 7450 MAX 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A13970 BNEY ThinkSystem 2.5" U.3 7450 MAX 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A13971 BNEL ThinkSystem 2.5" U.3 7450 MAX 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A64175 BE03 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD No 10
4XB7A17112 B96Z ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 10
4XB7A17113 B96T ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 10
4XB7A17114 B96P ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 10
2.5-inch SSDs - U.2 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A13941 BMGD ThinkSystem 2.5" U.2 P5520 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A13942 BMGE ThinkSystem 2.5" U.2 P5520 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A13943 BNEF ThinkSystem 2.5" U.2 P5520 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A13631 BNEQ ThinkSystem 2.5" U.2 P5520 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A17145 BCFT ThinkSystem 2.5" U.2 P5500 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 10
4XB7A17146 BCFW ThinkSystem 2.5" U.2 P5500 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 10
4XB7A17147 BCFU ThinkSystem 2.5" U.2 P5500 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD No 10
4XB7A38197 BC4Z ThinkSystem U.2 PM1733 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10
4XB7A38257 BE2A ThinkSystem U.2 PM1733 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 10
4XB7A38283 BE2E ThinkSystem U.2 PM1733 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10
4XB7A38258 BE2B ThinkSystem U.2 PM1733 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 10
4XB7A38284 BE2F ThinkSystem U.2 PM1733 15.36TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10
2.5-inch SSDs - U.3 PCIe 4.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A81951 BPKX ThinkSystem 2.5" U.3 PM1733a 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A81952 BPKY ThinkSystem 2.5" U.3 PM1733a 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A81953 BPKZ ThinkSystem 2.5" U.3 PM1733a 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A81954 BPL0 ThinkSystem 2.5" U.3 PM1733a 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A79646 BNF3 ThinkSystem 2.5" U.3 7450 PRO 960GB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A79647 BNF2 ThinkSystem 2.5" U.3 7450 PRO 1.92TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A79648 BNF5 ThinkSystem 2.5" U.3 7450 PRO 3.84TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A79649 BNF4 ThinkSystem 2.5" U.3 7450 PRO 7.68TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A83097 BQAV ThinkSystem 2.5" U.3 7450 PRO 15.36TB Read Intensive NVMe PCIe 4.0 x4 HS SSD Support 10
4XB7A64141 BE2G ThinkSystem U.3 Kioxia CM6-R 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10
4XB7A38269 BE2C ThinkSystem U.3 Kioxia CM6-R 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 10
4XB7A64142 BE2H ThinkSystem U.3 Kioxia CM6-R 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD No 10
4XB7A38270 BE2D ThinkSystem U.3 Kioxia CM6-R 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD SED Support 10

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 38. 2.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Write Intensive/Performance (10+ DWPD)
7N47A00081 AUMJ ThinkSystem 2.5" U.2 P4800X 375GB Write Intensive NVMe PCIe 3.0 x4 HS SSD No 10
7N47A00083 B2ZJ ThinkSystem 2.5" U.2 P4800X 750GB Write Intensive NVMe PCIe 3.0 x4 HS SSD No 10
7XB7A05923 AWG6 ThinkSystem U.2 PX04PMB 800GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD No 10
7XB7A05922 AWG7 ThinkSystem U.2 PX04PMB 1.6TB Performance NVMe PCIe 3.0 x4 Hot Swap SSD No 10
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A13936 B589 ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10
4XB7A13937 B58A ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10
4XB7A13938 B58B ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10
4XB7A08516 B21W ThinkSystem U.2 Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10
4XB7A08517 B21X ThinkSystem U.2 Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10
4XB7A08518 B21Y ThinkSystem U.2 Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10
4XB7A08519 B2XJ ThinkSystem U.2 Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10
7N47A00095 AUUY ThinkSystem U.2 PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10
7N47A00096 AUMF ThinkSystem U.2 PX04PMB 1.92TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 10
7SD7A05772 B11J ThinkSystem U.2 Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10
7SD7A05771 B11K ThinkSystem U.2 Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10
7SD7A05770 B11L ThinkSystem U.2 Intel P4600 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 10
2.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A10202 B58F ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10
4XB7A10204 B58G ThinkSystem 2.5" U.2 P4510 2.0TB Read Intensive NVMe PCIe 3.0 x4 HS SSD No 10
4XB7A10205 B58H ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10
4XB7A08513 B58J ThinkSystem U.2 Intel P4510 8.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10
4XB7A10175 B34N ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 10
4XB7A10176 B34P ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 10
4XB7A10177 B4D3 ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10
7N47A00984 AUV0 ThinkSystem U.2 PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 10
7N47A00985 AUUU ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 10
7SD7A05779 B11C ThinkSystem U.2 Intel P4500 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10
7SD7A05778 B11D ThinkSystem U.2 Intel P4500 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10
7SD7A05777 B11E ThinkSystem U.2 Intel P4500 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 10

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 39. 3.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00063 B1JJ ThinkSystem 3.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD No 4
3.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00038 AUU2 ThinkSystem 3.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00039 AUU3 ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00040 AUUC ThinkSystem 3.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD No 4
3.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00041 AUU4 ThinkSystem 3.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00042 AUU5 ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00043 AUU6 ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD No 4
7XB7A00044 AUU7 ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
7XB7A00045 B0YR ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
7XB7A00046 AUUG ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
7XB7A00067 B117 ThinkSystem 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A13906 B496 ThinkSystem 3.5" 14TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A13911 B7EZ ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A38266 BCFP ThinkSystem 3.5" 18TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
4XB7A80353 BPKU ThinkSystem 3.5" 20TB 7.2K SAS 12Gb Hot Swap 512e HDD No 4
3.5-inch hot-swap SED HDDs - 12 Gb NL SAS
7XB7A00065 B0YN ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 4
7XB7A00047 AUUH ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD FIPS Support 4
7XB7A00048 B0YP ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 4
7XB7A00066 B0YQ ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS Support 4
Table 40. 3.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00049 AUUF ThinkSystem 3.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00050 AUUD ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00051 AUU8 ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD No 4
7XB7A00052 AUUA ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
7XB7A00053 AUU9 ThinkSystem 3.5" 8TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
7XB7A00054 AUUB ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
7XB7A00068 B118 ThinkSystem 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A13907 B497 ThinkSystem 3.5" 14TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A13914 B7F0 ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A38130 BCFH ThinkSystem 3.5" 18TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
4XB7A80354 BPKV ThinkSystem 3.5" 20TB 7.2K SATA 6Gb Hot Swap 512e HDD No 4
Table 41. 3.5-inch hot-swap 24 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 24 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A80344 BNW7 ThinkSystem 3.5" PM1655 800GB Mixed Use SAS 24Gb HS SSD Support 4
4XB7A80345 BNWA ThinkSystem 3.5" PM1655 1.6TB Mixed Use SAS 24Gb HS SSD Support 4
4XB7A80346 BNWB ThinkSystem 3.5" PM1655 3.2TB Mixed Use SAS 24Gb HS SSD Support 4
4XB7A80347 BP3G ThinkSystem 3.5" PM1655 6.4TB Mixed Use SAS 24Gb HS SSD Support 4
3.5-inch hot-swap SSDs - 24 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A80324 BNWD ThinkSystem 3.5" PM1653 960GB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80325 BNWG ThinkSystem 3.5" PM1653 1.92TB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80326 BNWH ThinkSystem 3.5" PM1653 3.84TB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80327 BP3F ThinkSystem 3.5" PM1653 7.68TB Read Intensive SAS 24Gb HS SSD Support 4
4XB7A80328 BP3H ThinkSystem 3.5" PM1653 15.36TB Read Intensive SAS 24Gb HS SSD Support 4
Table 42. 3.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 12 Gb SAS - Write Intensive/Performance (10+ DWPD)
4XB7A70011 BG03 ThinkSystem 3.5" Nytro 3732 400GB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A70010 BG02 ThinkSystem 3.5" Nytro 3732 800GB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A70009 BG01 ThinkSystem 3.5" Nytro 3732 1.6TB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A70008 BG00 ThinkSystem 3.5" Nytro 3732 3.2TB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A10234 B4Y8 ThinkSystem 3.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A10235 B4Y9 ThinkSystem 3.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD No 4
4XB7A10236 B4YA ThinkSystem 3.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD No 4
7N47A00997 B16Z ThinkSystem 3.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD No 4
7N47A00998 B170 ThinkSystem 3.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD No 4
7N47A00999 B171 ThinkSystem 3.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD No 4
7SD7A05751 B11S ThinkSystem 3.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS Support 4
7SD7A05750 B11T ThinkSystem 3.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS Support 4
7SD7A05749 B11U ThinkSystem 3.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS Support 4
3.5-inch hot-swap SSDs - 12 Gb SAS - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17066 B8HT ThinkSystem 3.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A17043 B8JN ThinkSystem 3.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A17067 B8JK ThinkSystem 3.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A17068 B8JG ThinkSystem 3.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A13657 B4A3 ThinkSystem 3.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A13658 B4A4 ThinkSystem 3.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A13659 B4A5 ThinkSystem 3.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A10188 B2XD ThinkSystem 3.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A10187 B2XE ThinkSystem 3.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD No 4
4XB7A10189 B2XL ThinkSystem 3.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD No 4
3.5-inch hot-swap SSDs - 12 Gb SAS - Read Intensive/Entry/Capacity (<3 DWPD)
4XB7A17058 B91E ThinkSystem 3.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD No 4
4XB7A17059 BEVK ThinkSystem 3.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD No 4
4XB7A13649 B4A8 ThinkSystem 3.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD No 4
4XB7A10173 B2XC ThinkSystem 3.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD No 4
Table 43. 3.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch hot-swap SSDs - 6 Gb SATA - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17137 BA4W ThinkSystem 3.5" S4620 480GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17138 BA4X ThinkSystem 3.5" S4620 960GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17139 BA4Y ThinkSystem 3.5" S4620 1.92TB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17140 BK7P ThinkSystem 3.5" S4620 3.84TB Mixed Use SATA 6Gb HS SSD No 4
4XB7A17096 B8JL ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17097 B8JF ThinkSystem 3.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17098 B8J0 ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17099 B8HR ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A17100 B8HX ThinkSystem 3.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A13639 B49R ThinkSystem 3.5" S4610 240GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A13640 B49S ThinkSystem 3.5" S4610 480GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A13641 B49T ThinkSystem 3.5" S4610 960GB Mixed Use SATA 6Gb HS SSD No 4
4XB7A13642 B49U ThinkSystem 3.5" S4610 1.92TB Mixed Use SATA 6Gb HS SSD No 4
4XB7A13643 B49V ThinkSystem 3.5" S4610 3.84TB Mixed Use SATA 6Gb HS SSD No 4
4XB7A10242 B48D ThinkSystem 3.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10243 B48E ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10244 B48F ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10245 B48G ThinkSystem 3.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 4
4XB7A10246 B48H ThinkSystem 3.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05718 B0ZT ThinkSystem 3.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05717 B0ZU ThinkSystem 3.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05716 B0ZV ThinkSystem 3.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05715 B109 ThinkSystem 3.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05760 B111 ThinkSystem 3.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05759 B112 ThinkSystem 3.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05758 B113 ThinkSystem 3.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05757 B114 ThinkSystem 3.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD No 4
7SD7A05756 B115 ThinkSystem 3.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD No 4
3.5-inch hot-swap SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A17118 BA7K ThinkSystem 3.5" S4520 240GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17119 BA7L ThinkSystem 3.5" S4520 480GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17120 BA7M ThinkSystem 3.5" S4520 960GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17121 BA7N ThinkSystem 3.5" S4520 1.92TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17122 BK7F ThinkSystem 3.5" S4520 3.84TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17123 BK7G ThinkSystem 3.5" S4520 7.68TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A38276 BCTH ThinkSystem 3.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38277 BCTJ ThinkSystem 3.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38278 BCTK ThinkSystem 3.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38279 BCTL ThinkSystem 3.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A38281 BCTM ThinkSystem 3.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17081 B8JB ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17082 B8J9 ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17083 B8JC ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17084 B8HZ ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17085 B8HQ ThinkSystem 3.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17086 B8J3 ThinkSystem 3.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A13625 B49D ThinkSystem 3.5" S4510 240GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A13626 B49E ThinkSystem 3.5" S4510 480GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A13627 B49F ThinkSystem 3.5" S4510 960GB Read Intensive SATA 6Gb HS SSD No 4
4XB7A13628 B49G ThinkSystem 3.5" S4510 1.92TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A13629 B49H ThinkSystem 3.5" S4510 3.84TB Read Intensive SATA 6Gb HS SSD No 4
4XB7A17176 B6TM ThinkSystem 3.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17177 B6TN ThinkSystem 3.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17178 B6TP ThinkSystem 3.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17179 B6JY ThinkSystem 3.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A17180 B6JZ ThinkSystem 3.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
7N47A00115 AUUS ThinkSystem 3.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD No 4
7N47A00116 AUUN ThinkSystem 3.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD No 4
7N47A00106 AUUT ThinkSystem 3.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD No 4
7N47A00105 AUUW ThinkSystem 3.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD No 4
7SD7A05737 B0Z3 ThinkSystem 3.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD No 4
7SD7A05736 B0Z4 ThinkSystem 3.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD No 4
7SD7A05735 B0Z5 ThinkSystem 3.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD No 4
7SD7A05734 B0Z6 ThinkSystem 3.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
7SD7A05733 B0Z7 ThinkSystem 3.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10158 B2X7 ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10159 B2X8 ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10160 B2X9 ThinkSystem 3.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10161 B2XA ThinkSystem 3.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A10162 B2XB ThinkSystem 3.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A08506 B10S ThinkSystem 3.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A08507 B10T ThinkSystem 3.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A08508 B10U ThinkSystem 3.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD No 4
4XB7A08509 B10V ThinkSystem 3.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD No 4
Table 44. 3.5-inch hot-swap PCIe 4.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch SSDs - U.2 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A17141 BNEK ThinkSystem 3.5" U.2 P5620 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 4
4XB7A17143 BNEM ThinkSystem 3.5" U.2 P5620 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 4
4XB7A17144 BNEN ThinkSystem 3.5" U.2 P5620 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD Support 4
4XB7A17155 BCFM ThinkSystem 3.5" U.2 P5600 1.6TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 4
4XB7A17156 BCFJ ThinkSystem 3.5" U.2 P5600 3.2TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 4
4XB7A17157 BCFQ ThinkSystem 3.5" U.2 P5600 6.4TB Mixed Use NVMe PCIe 4.0 x4 HS SSD No 4
3.5-inch SSDs - U.3 PCIe 4.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A64176 BE04 ThinkSystem 3.5" Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD No 4
4XB7A17115 B96V ThinkSystem 3.5" Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 4
4XB7A17116 B96K ThinkSystem 3.5" Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 4
4XB7A17117 B96W ThinkSystem 3.5" Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD No 4

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 45. 3.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature
code
Description SED
support
Max
Qty
3.5-inch SSDs - U.2 PCIe 3.0 NVMe - Mixed Use/Mainstream (3-5 DWPD)
4XB7A13944 B58C ThinkSystem 3.5" Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A13945 B58D ThinkSystem 3.5" Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A13946 B58E ThinkSystem 3.5" Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A08532 B21Z ThinkSystem 3.5" Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08533 B220 ThinkSystem 3.5" Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08534 B221 ThinkSystem 3.5" Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08535 B2XK ThinkSystem 3.5" Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A08528 B2XF ThinkSystem 3.5" Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A08529 B2XG ThinkSystem 3.5" Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
4XB7A08530 B2XH ThinkSystem 3.5" Intel P4600 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD No 4
7N47A00982 AUUM ThinkSystem 3.5" PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD No 4
3.5-inch SSDs - U.2 PCIe 3.0 NVMe - Read Intensive/Entry (<3 DWPD)
4XB7A10178 B34Q ThinkSystem 3.5" PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A10179 B34R ThinkSystem 3.5" PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4
4XB7A10180 B4D4 ThinkSystem 3.5" PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD No 4
7N47A00987 AUUX ThinkSystem 3.5" PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4
7N47A00988 AUVZ ThinkSystem 3.5" PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD No 4

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 46. M.2 SATA drives
Part number Feature
code
Description SED
support
Max
Qty
M.2 SSDs - 6 Gb SATA - Read Intensive/Entry (<3 DWPD)
4XB7A90105 BXMK ThinkSystem M.2 ER2 240GB Read Intensive SATA 6Gb NHS SSD (China only) Support 2
4XB7A90106 BXMJ ThinkSystem M.2 ER2 480GB Read Intensive SATA 6Gb NHS SSD (China only) Support 2
4XB7A82286 BQ1Z ThinkSystem M.2 5400 PRO 240GB Read Intensive SATA 6Gb NHS SSD Support 2
4XB7A82287 BQ1Y ThinkSystem M.2 5400 PRO 480GB Read Intensive SATA 6Gb NHS SSD Support 2
7N47A00129 AUUL ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD No 2
7N47A00130 AUUV ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A14049 B5S4 ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD No 2
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A17071 B8HS ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD No 2
4XB7A17073 B919 ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD No 2

USB memory key

For general portable storage needs, the server also supports the USB memory key option that is listed in the following table.

Table 47. USB memory key
Part number Feature Description
4X77A08621 B8NV ThinkSystem 32GB USB Flash Drive

Optical drives

The server supports the external USB optical drive listed in the following table.

Table 48. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

I/O expansion

The SR630 server supports one LOM card slot and up to four PCIe slots: one slot on the system planar that is dedicated to an internal storage controller and up to three PCIe slots with different riser cards installed into two riser sockets on the system planar (one riser socket supports installation of one riser card).

The slot form factors are as follows:

  • LOM card slot
  • Slot 1: PCIe 3.0 x8, ML2 x8, or ML2 x16; low profile
  • Slot 2: PCIe 3.0 x16 or x8; low profile or full-height, half-length
  • Slot 3: PCIe 3.0 x16; low profile
  • Slot 4: PCIe 3.0 x8 (dedicated to an internal storage controller)

Configuration notes:

  • Slot 3 requires the second processor to be installed.
  • Slots 1 and 2 are not present if the Rear HDD Kit is installed.
  • The COM Port Upgrade Kit is installed in place of one of the PCIe slots 1, 2, or 3.

The locations of the PCIe slots are shown in the following figure.

Slot locations
Figure 9. Slot locations

Riser 1 supplies slots 1 and 2, and Riser 2 supplies slot 3. The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed, as shown in the following table.

Table 49. Slots available for use
Riser Card 1 Riser Card 2 Slots available for use
Processor 1 Processor 2
None None LOM, 4 -
None PCIe x16 LOM, 4 3
PCIe x8/x16, PCIe x8ML2/x16, or PCIe x16ML2/x8 None LOM, 1, 2, 4 -
PCIe x8/x16, PCIe x8ML2/x16, or PCIe x16ML2/x8 PCIe x16 LOM, 1, 2, 4 3

The following table lists available PCIe riser card options.

Table 50. PCIe riser cards and miscellaneous options
Part number Feature code Description Maximum quantity
x8 Riser Card 1 options (Riser card 1 supplies slots 1 and 2)
7XH7A02682 AUWC ThinkSystem SR530/SR570/SR630 x8/x16 PCIe LP+LP Riser 1 Kit 1
7XH7A05893 None* ThinkSystem SR530/SR570/SR630 x8/x16 PCIe LP+FH Riser 1 Kit 1
7XH7A02683 AUWE ThinkSystem SR630 x8ML2/x16 PCIe LP+LP Riser 1 Kit 1
7XH7A05894 None* ThinkSystem SR630 x8ML2/x16 PCIe LP+FH Riser 1 Kit 1
7XH7A02684 AUWD ThinkSystem SR630 x16ML2/x8 PCIe LP+LP Riser 1 Kit 1
7XH7A05895 None* ThinkSystem SR630 x16ML2/x8 PCIe LP+FH Riser 1 Kit 1
Riser Card 2 option (Riser card 2 supplies slot 3)
7XH7A02685 AUWA ThinkSystem SR530/SR570/SR630 x16 PCIe LP Riser 2 Kit 1
Serial port upgrade kit
4Z17A80446 BMNJ ThinkSystem COM Port Upgrade Kit v2  
7Z17A02577 AUSL ThinkSystem COM Port Upgrade Kit 1

* The LP+FH Riser 1 can be factory-installed by selecting the feature codes of the LP+LP Riser 1 (AUWC, AUWD, or AUWE) and LP+FH Bracket (AUWS).

The COM Port Upgrade Kit, part number 7Z17A02577, is used for mounting the external serial port on the rear of the SR630. This option includes the bracket and the cable. The COM Port option is mounted in place of one of the PCIe slots 1, 2, or 3.

Network adapters

The SR630 server supports up to four onboard network ports with optional LOM cards that use the Intel Ethernet Connection X722 1/10 GbE technology integrated into the Intel C624 Platform Controller Hub (PCH). The server also supports ML2 adapters that are installed in the custom ML2 slot provided by an ML2 riser card. The LOM cards and ML2 network adapters support direct connectivity to the XClarity Controller via the Network Controller Sideband Interface (NSCI) for out-of-band systems management.

The integrated Intel Ethernet Connection X722 has the following features:

  • Four 1/10 Gb Ethernet capable ports (no 10/100 Mb Ethernet support)
  • NIC Teaming (load balancing and failover)
  • Data Center Bridging
  • iWARP (RDMA over IP)
  • VMDq and SR-IOV virtualization (10 Gb speeds only, 4 PFs, 128 VFs per device)
  • IEEE 802.1q Virtual Local Area Networks (VLANs)
  • NVGRE, VXLAN, IPinGRE, and MACinUDP network virtualization
  • IEEE 802.1Qbg Edge Virtual Bridging
  • TCP, IP, and UDP checksum offload
  • Large Send Offload (LSO) and Generic Send Offload (GSO)
  • Receive Side Scaling (RSS) for TCP and UDP traffic
  • Jumbo frames up to 9.5 Kbytes

The following table lists the network adapters that are supported with the SR630 server.

Table 51. Network adapters
Part number Feature
code
Description Max
qty#
I/O slots
supported
LOM cards - Gigabit Ethernet
7ZT7A00544 AUKG ThinkSystem 1Gb 2-port RJ45 LOM 1 LOM slot
7ZT7A00545 AUKH ThinkSystem 1Gb 4-port RJ45 LOM 1 LOM slot
LOM cards - 10 Gb Ethernet
7ZT7A00548 AUKL ThinkSystem 10Gb 2-port Base-T LOM 1 LOM slot
7ZT7A00546 AUKJ ThinkSystem 10Gb 2-port SFP+ LOM 1* LOM slot
7ZT7A00549 AUKM ThinkSystem 10Gb 4-port Base-T LOM 1 LOM slot
7ZT7A00547 AUKK ThinkSystem 10Gb 4-port SFP+ LOM 1* LOM slot
ML2 adapters - Gigabit Ethernet
7ZT7A00536 AUKW ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapter 1 1 (ML2)
ML2 adapters - 10 Gb Ethernet
7ZT7A00497 AUKQ Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter 1 1 (ML2)
00AG560 AT7U Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter 1* 1 (ML2)
01CV770 AU7Z Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 1* 1 (ML2)
00JY940 ATRH Intel X710-DA2 ML2 2x10GbE SFP+ Adapter 1* 1 (ML2)
ML2 adapters - 25 Gb Ethernet
00MN990 ATZR Mellanox ConnectX-4 Lx 10/25GbE SFP28 1-port ML2 Ethernet Adapter 1* 1 (ML2)
7ZT7A00507 AUKU Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port ML2 Ethernet Adapter 1* 1 (ML2)
ML2 adapters - FDR InfiniBand
7ZT7A00501 AUKR Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter 1* 1 (ML2)
PCIe Low Profile adapters - 1 Gb Ethernet
7ZT7A00482 AUZX Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter 2 / 3 2, 3, 1
7ZT7A00484 AUZV Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter 2 / 3 2, 3, 1
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter 2 / 3 2, 3, 1
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter 2 / 3 2, 3, 1
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter 2 / 3 2, 3, 1
PCIe Low Profile adapters - 10 Gb Ethernet
7ZT7A00496 AUKP Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter 2 / 3 2, 3, 1
00AG570 AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter 2 / 3* 2, 3, 1
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 2 / 3* 2, 3, 1
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter 2 / 3 2, 3, 1
7ZT7A00537 AUKX Intel X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A79699 BMXB ThinkSystem Intel X710-T4L 10GBase-T 4-Port PCIe Ethernet Adapter 2 / 3 2, 3, 1
4XC7A08225 B31G QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter 2 / 3 2, 3, 1
PCIe Full Height adapters - 10 Gb Ethernet
7ZT7A00493 AUKN Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter 1 / 1* 2
PCIe Low Profile adapters - 25 Gb Ethernet
7ZT7A00505 AUKS Broadcom 57412 10/25GbE SFP28 1-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A08238 B5T0 Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A08316 BD49 Broadcom 57454 10/25GbE SFP28 4-port PCIe Ethernet Adapter V2 1 / 1
4XC7A08295 BCD6 Intel E810-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
7XC7A05523 B0WY Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
01GR250 AUAJ Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A62574 BEAP Mellanox ConnectX-5 EN 10/25GbE SFP28 2-port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A62580 BE4U Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A16683 B5XZ Mellanox Innova-2 ConnectX-5 FPGA 25GbE 2-port Adapter 1 / 2* 2, 3†
4XC7A08228 B21R QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
4XC7A62581 BHE2 Solarflare X2522-Plus 10/25GbE SFP28 2-Port PCIe Ethernet Adapter 2 / 3* 2, 3, 1
PCIe Low Profile adapters - 40 Gb Ethernet
00MM950 ATRN Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter 2 / 3* 2, 3, 1
4XC7A08229 B31C Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter 1 / 2*^ 2, 3†
PCIe Low Profiles adapters - FDR InfiniBand
7XC7A05524 B0WX Mellanox ConnectX-4 PCIe FDR 1-Port QSFP VPI Adapter 2 / 3* 2, 3, 1
7ZT7A00500 AUVG Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter 2 / 3* 2, 3, 1
PCIe x16 Low Profile adapters - 100 Gb Ethernet / EDR InfiniBand
00KH924 ASWQ Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter 1 / 2* 2, 3†
00MM960 ATRP Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter 1 / 2* 2, 3†
4XC7A08248 B8PP Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe Ethernet Adapter 1 / 2* 2, 3†
4XC7A76757 BLC2 ThinkSystem Xilinx Alveo U50 Data Center Accelerator Adapter 1 / 2* 2, 3†
PCIe x16 Low Profile adapters - HDR InfiniBand
4C57A15326 B4RC Mellanox ConnectX-6 HDR/200GbE QSFP56 1-port PCIe 4 VPI Adapter 1 / 1* 2†‡
4C57A14179 B4RB Mellanox HDR/200GbE 2x PCIe Aux Kit 1 / 1* 3†‡
4C57A14177 B4R9 Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter 1 / 2* 2, 3†
4C57A14178 B4RA Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter 1 / 2* 2, 3†
PCIe Low Profile adapters - Omni-Path
00WE023 AU0A Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA 1 / 3* 2, 3, 1
00WE027 AU0B Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA 1 / 2* 2, 3†

# The maximum quantity shown is with one processor / two processors (this does not apply to LOM cards and ML2 adapters).
* The adapter comes without transceivers or cables; for ordering transceivers or cables, see the product guide for the adapter.
† The adapter is supported in the PCIe x16 slots supplied by the riser cards 1 and 2.
^ The 25 GbE connectivity requires the optional Mellanox QSA 100G to 25G Cable Adapter (4G17A10853) (one per port); the supported cables include 25 GbE passive DAC and active optical cables (25 GbE transceivers not supported)
‡ The ConnectX-6 HDR adapter is supported only in the configurations with two processors, and it requires the HDR/200GbE 2x PCIe Aux Kit.
§ In the SR630, this adapter requires a full-height bracket and must be installed in a full-height slot. The use of a low-profile bracket and slot is not supported.

For more information, see the list of Product Guides in the Ethernet Adapters category:
http://lenovopress.com/servers/options/ethernet#rt=product-guide

Configuration notes:

  • ML2 network adapters are supported in the ML2 x8 slot 1 supplied by the x8ML2/x16 Riser Card 1 (7XH7A02683 or 7XH7A05894).
  • PCIe full-height network adapters are supported in the full-height PCIe x8 or x16 slot 2 supplied by the riser card 1.
  • PCIe x16 Low Profile network adapters and Omni-Path adapters are supported in the full-height and low profile PCIe x16 slots supplied by the riser cards 1 and 2.
  • PCIe Low Profile network adapters (except PCIe x16 adapters and Omni-Path adapters) are supported in the full-height and low profile PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • Supported transceivers or DAC cables should be purchased for the SFP+, SFP28, QSFP+, and QSFP28 adapters, and UTP Category 6 or Category 5e cables should be purchased for the 10 GbE (Cat6) or 1 GbE (Cat5e or Cat6) RJ-45 adapters. The maximum number of transceivers or cables that are supported per adapter equals the quantity of the adapter ports, and all adapter ports must have the same type of the transceiver or cable selected.
  • E810 Ethernet and X350 RAID/HBAs: The use of both an Intel E810 network adapter and an X350 HBA/RAID adapter (9350, 5350 and 4350) is currently not supported in ThinkSystem servers. For details see Support Tip HT513226. Planned support for this combination of adapters is 2Q/2024.

SAS adapters for external storage

The following table lists SAS RAID controllers and HBAs for external storage attachments that are supported by the SR630 server.

Table 52. SAS RAID adapters and HBAs for external storage
Part number Feature code Description Maximum quantity* I/O slots supported
12 Gbps SAS RAID adapters
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter 2 / 2 2, 3, 1
4Y37A78836 BNWJ ThinkSystem RAID 940-8e 4GB Flash PCIe Gen4 12Gb Adapter 2 / 2 2, 3, 1
12 Gbps SAS HBAs
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA 2 / 2 2, 3, 1
7Y37A01091 AUNN ThinkSystem 430-16e SAS/SATA 12Gb HBA 2 / 2 2, 3, 1
4Y37A78837 BNWK ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA 2 / 2 2, 3, 1
4Y37A09724 B8P7 ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA 2 / 2 2, 3, 1

* The maximum quantity shown is with one processor / two processors.

For a comparison of the functions of the supported external storage adapters, see the ThinkSystem RAID Adapter and HBA Reference:
https://lenovopress.com/lp1288#sr630-support=SR630&internal-or-external-ports=External

Configuration notes:

  • Low profile SAS RAID controllers and HBAs for external storage are supported in the low profile and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • In the configurations without GPU installed, the total quantity of the RAID 730-8i 2GB, RAID 930-8i, RAID 930-16i, and RAID 930-8e controllers in the server must not exceed 2 (up to 2 supercapacitors can be mounted in the server).
  • In the configurations with GPU installed, the total quantity of the RAID 730-8i 2GB, RAID 930-8i, RAID 930-16i, and RAID 930-8e controllers in the server must not exceed 1 (the storage controller can be installed only in the PCIe slot 1; the PCIe slots 3 and 4 cannot be used if the GPU adapter is installed).
  • The RAID 930-8e controller cannot be used in the configurations with the RAID 730-8i 2GB controller.

Mixing storage adapter families: The following HBA/RAID adapter combinations are supported:

  • X30 external adapters with other X30 adapters (internal or external)
  • X40 external adapters with other X40 adapters (internal or external)
  • X40 external adapters with X350 internal adapters

The following HBA/RAID adapter combinations are not supported:

  • X30 adapters (internal or external) with X40 adapters (internal or external)
  • X30 adapters (internal or external) with X350 internal adapters

For more information, see the list of Product Guides in the following categories:

Fibre Channel host bus adapters

The following table lists Fibre Channel HBAs supported by the SR630 server.

Table 53. Fibre Channel HBAs
Part number Feature code Description Maximum quantity* I/O slots supported
64 Gb Fibre Channel - PCIe
4XC7A77485 BLC1 Emulex LPe36002 64Gb 2-port PCIe Fibre Channel Adapter 2 / 3 2, 3, 1
32 Gb Fibre Channel - PCIe
4XC7A76525 BJ3H ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter V2 2 / 3 2, 3, 1
4XC7A76498 BJ3G ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter v2 2 / 3 2, 3, 1
4XC7A08250 B5SX Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter 2 / 3 2, 3, 1
4XC7A08251 B5SY Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter 2 / 3 2, 3, 1
7ZT7A00517 AUNT Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ FC HBA 2 / 3 2, 3, 1
7ZT7A00519 AUNV Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ FC HBA 2 / 3 2, 3, 1
7ZT7A00516 AUNS QLogic QLE2740 PCIe 32Gb 1-Port SFP+ FC HBA 2 / 3 2, 3, 1
7ZT7A00518 AUNU QLogic QLE2742 PCIe 32Gb 2-Port SFP+ FC HBA 2 / 3 2, 3, 1
16 Gb Fibre Channel - PCIe
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA 2 / 3 2, 3, 1
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA 2 / 3 2, 3, 1
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA 2 / 3 2, 3, 1
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA 2 / 3 2, 3, 1
8 Gb Fibre Channel - PCIe (available only in AP and PRC)
4XC7A08220 B0WZ Emulex LPe12000-M8-L PCIe 8Gb 1-Port SFP+ FC HBA 2 / 3 2, 3, 1
4XC7A08221 B0X0 Emulex LPe12002-M8-L PCIe 8Gb 2-Port SFP+ FC HBA 2 / 3 2, 3, 1

* The maximum quantity shown is with one processor / two processors.

Configuration note: FC HBAs are supported in the low profile and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.

For more information, see the list of Product Guides in the Host bus adapters category:
http://lenovopress.com/servers/options/hba#rt=product-guide

Flash storage adapters

The SR630 server supports the flash storage adapters listed in the following table.

Table 54. Flash storage adapters
Part number Feature code Description Maximum quantity* I/O slots supported
Performance Flash Adapters - PX04PMC
7XB7A05925 AWG8 PX04PMC 1.6TB Performance NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
7XB7A05924 AWG9 PX04PMC 3.2TB Performance NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
Mainstream Flash Adapters - CM5-V
4XB7A38234 BCGJ CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
4XB7A38237 BCGK CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
4XB7A38240 BCGL CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
Mainstream Flash Adapters - CM5-V
4XB7A08520 B32L CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
4XB7A08521 B32M CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
4XB7A08522 B32N CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
Mainstream Flash Adapters - P4600
7SD7A05769 B11X Intel P4600 2.0TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
7SD7A05768 B11Y Intel P4600 4.0TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
Mainstream Flash Adapters - PX04PMC
7N47A00097 AUUP PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
7N47A00098 AUVY PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
Entry Flash Adapters - P4500
7SD7A05776 B11Z Intel P4500 4.0TB Entry NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1
7SD7A05775 B120 Intel P4500 8.0TB Entry NVMe PCIe 3.0 x4 Flash Adapter 2 / 3 2, 3, 1

* The maximum quantity shown is with one processor / two processors.

Configuration notes:

  • Flash storage adapters are supported in the low profile and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
  • The Flash storage adapters are supported only in the environments with the air temperature of up to 35 °C (95 °F).

For more information, see the list of Product Guides in the Flash storage adapters category:
http://lenovopress.com/servers/options/ssdadapter#rt=product-guide

GPU adapters

The SR630 server supports graphics processing units (GPUs) listed in the following table.

Table 55. GPU adapters
Part number Feature code Description Maximum quantity* I/O slots supported
Full-height, full-length PCIe 3.0 x16 single-wide GPU adapters
7C57A02877 AUW6 NVIDIA Quadro P2000 PCIe Active GPU 1 / 1 2
4X67A14935 B7JW ThinkSystem NVIDIA Quadro P2200 5GB PCIe Active GPU 1 / 1 2
4V17A10255 B225 ThinkSystem NVIDIA Quadro P4000 8GB PCIe Active GPU 1 / 1 2
4X67A14934 B6CG ThinkSystem NVIDIA Quadro RTX 4000 8GB PCIe Active GPU 1 / 1 2
Low profile PCIe 3.0 x16 single-wide GPU adapters
7C57A02894 B226 ThinkSystem NVIDIA Quadro P600 2GB PCIe Active GPU 2 / 3 3, 1, 2
4X67A11584 B31D ThinkSystem NVIDIA Quadro P620 2GB PCIe Active GPU 2 / 3 3, 1, 2
7C57A02892 B227 ThinkSystem NVIDIA Tesla P4 8GB PCIe Passive GPU 1 / 2 3, 1
4X67A14926 B4YB ThinkSystem NVIDIA Tesla T4 16GB PCIe Passive GPU 1 / 2 3, 1
4X67A81547 BP05 ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU 1 / 2 3, 1
CTO only BQZT ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU w/o CEC 1 / 2 3, 1
GPU upgrade kits
4XH7A08765 None** ThinkSystem SR630 GPU Upgrade Kit 1 -

* The maximum quantity shown is with one processor / two processors.
** Field upgrade only.

Configuration notes:

  • Some NVIDIA A Series GPUs are available as two feature codes, one with a CEC chip and one without a CEC chip (ones without the CEC chip have "w/o CEC" in the name). The CEC is a secondary Hardware Root of Trust (RoT) module that provides an additional layer of security, which can be used by customers who have high regulatory requirements or high security standards. NVIDIA uses a multi-layered security model and hence the protection offered by the primary Root of Trust embedded in the GPU is expected to be sufficient for most customers. The CEC defeatured products still offer Secure Boot, Secure Firmware Update, Firmware Rollback Protection, and In-Band Firmware Update Disable. Specifically, without the CEC chip, the GPU does not support Key Revocation or Firmware Attestation. CEC and non-CEC GPUs of the same type of GPU can be mixed in field upgrades.

  • The full-height GPU adapters require the PCIe x16 FH riser card for the PCIe slot 2, and the PCIe slot 3 cannot be used. The low profile GPU adapters are supported in the PCIe x8 and x16 low-profile slots supplied by the riser cards 1 and 2.
  • The full-height GPU adapters require the GPU Upgrade Kit (4XH7A08765).
  • If the full-height GPU adapter is installed, the internal slot for a storage controller cannot be used.
  • The GPU adapters are not supported in the following configurations:
    • Rear HDD kit installed.
    • 10x U.2 PCIe NVMe drive bays installed.
    • DCPMMs installed.
  • Configurations with any one GPU adapter or two P600 or P620 GPU adapters are supported only with the 750 W or 1100 W power supplies. Configurations with two P4 or three P600 or P620 GPU adapters are supported only with the 1100 W power supplies.
  • The P2000 or P2200 GPU adapters are supported with the processors of up to 140 W TDP. The GPU adapters other than P2000 or P2200 are supported with the processors of up to 165 W TDP (excluding Gold 6240Y, 6244, 6246, and 6252N processors).
  • The RTX4000 GPU adapter is supported with the processors of up to 165 W TDP in the configurations with 8x 2.5-inch drive bays, or with the processors of up to 150 W TDP in the configurations with 4x 3.5-inch SAS/SATA or AnyBay, or 6x 2.5-inch SAS/SATA & 4x 2.5-inch AnyBay drive bays.
  • The GPU adapters are supported only in the ASHRAE A2 environments (up to 35 °C [95 °F]) with the following exceptions:
    • Two P4 or T4 or A2 GPU adapters are supported at the ambient temperature of up to 30 °C [86 °F]), and the server performance might be impacted in case of a system fan failure.
    • Three P600 or P620 adapters are supported at the ambient temperature of up to 30 °C [86 °F]).

Cooling

The SR630 server supports up to seven hot-swap system fans that provide N+1 cooling redundancy. SR630 server models with one processor include five system fans, and server models with two processors include seven system fans. The fans are dual-rotor counter-rotating units, which means that the fans have two separate propellors, one in front of the other, and that the propellors rotate in opposite directions.

In the case of a system fan failure, performance might be impacted if any of the following processors are installed:

  • 2nd Gen processors with 200 W or 205 W TDP, or Xeon 6240Y, 6244, 6246, or 6252N processors
  • 1st Gen processors Xeon 6144, 6146, 6154, 8168, 8180, and 8180M

The installation of a 2nd processor requires an extra cooling fan be installed. For CTO orders, fans are derived by the configurator. For field upgrades, 1st Gen processor option part numbers include this fan however 2nd Gen processor options do not included the fan and it must be ordered separately using SR630 Fan Option Kit listed in the following table.

Table 56. Cooling options
Part number Feature code Description Maximum quantity
4F17A12350 AUW7 ThinkSystem SR630 Fan Option Kit (2nd Gen processors only) 1

Power supplies

The SR630 server supports up to two redundant power supplies and is capable of N+N redundancy depending on the configuration. A second power supply can be added to the models that come with one power supply.

The following table lists the power supply options.

Table 57. Power supplies
Part number Feature code Description Maximum quantity
7N67A00882 AVW8 ThinkSystem 550W (230V/115V) Platinum Hot-Swap Power Supply 2
7N67A00883 AVWA ThinkSystem 750W (230/115V) Platinum Hot-Swap Power Supply 2
7N67A00884 AVW9 ThinkSystem 750W (230V) Titanium Hot-Swap Power Supply 2
4P57A82020 BR1Y ThinkSystem V1 750W (230Vac) Titanium Hot Swap Power Supply 2
7N67A00885 AVWB ThinkSystem 1100W (230V/115V) Platinum Hot-Swap Power Supply 2
4P57A15363* B4Z5* ThinkSystem 1100W -48V DC Power Supply 2

* -48V DC power supply is only available via Special Bid

Power supply options do not include a line cord. For server configurations, the inclusion of a power cord is model dependent. Configure-to-order models can be configured without power cords if desired.

Configuration notes:

  • Minimum of 1 and maximum of 2 power supplies per system.
  • If 2 are installed, power supplies must be identical.
  • AC power supplies support AC (Worldwide) and HVDC (PRC only) power sources
  • AC power supplies have a C14 connector. The -48V DC power supply has a Positronic PLB3W3M1000/AA connector.

Important: The Standalone Solution Configuration Tool (SSCT) and Lenovo Data Center Solution Configurator (DCSC) power supply selection rules allow a subset of possible configurations due to power restrictions. Configurations that cannot be built in SSCT or DCSC due to power restrictions may still be supported. To verify support and ensure that the right power supply is chosen for optimal performance, you should always validate your server configuration using the latest version of the Lenovo Capacity Planner:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Power cords

Line cords and rack power cables with C13 connectors can be ordered as listed in the following table.

110V customers: If you plan to use the 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Table 58. Power cords
Part number Feature code Description
Rack cables - C13 to C14
SL67B08593 BPHZ 0.5m, 10A/100-250V, C13 to C14 Jumper Cord
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08367 B0N5 1.0m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08368 B0N6 1.5m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08365 B0N4 2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable
Rack cables - C13 to C14 (Y-cable)
00Y3046 A4VQ 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable
00Y3047 A4VR 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable
Rack cables - C13 to C20
39Y7938 6204 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable
Rack cables - C13 to C20 (Y-cable)
47C2491 A3SW 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable
47C2492 A3SX 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable
47C2493 A3SY 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable
47C2494 A3SZ 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable
Line cords
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
39Y7928 6210 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y2376 6572 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
81Y2386 6567 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2380 6493 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
46M2593 A1RE 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
81Y2379 6576 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
39Y7925 6219 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord
81Y2385 6494 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
00WH545 6401 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord

For the -48V DC Power Supply, the following power cable is supported.

Table 59. -48V DC power cable
Part number Feature code Description
CTO only B93F ThinkSystem 2.5m,DC Cable

Systems management

The SR630 supports the following systems management tools:

Lenovo XClarity Controller

The SR630 server contains Lenovo XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. XClarity Controller offers three functional levels: Standard, Advanced, and Enterprise.

By default, the SR630 server includes XClarity Controller Standard features, and it can be upgraded to Advanced or Enterprise functionality by using the Features on Demand (FoD) upgrades.

XClarity Controller Standard offers the following capabilities:

  • Gathering and viewing system information and inventory
  • Monitoring system status and health
  • Alerting and notifications
  • Event logging
  • Configuring network connectivity
  • Configuring security
  • Updating system firmware
  • Configuring server settings and devices
  • Real-time power usage monitoring
  • Remotely controlling server power (Power on, Power off, Restart)
  • Managing FoD activation keys
  • Redirecting serial console via IPMI
  • Capturing the video display contents when an operating system hang condition is detected 

XClarity Controller Advanced Upgrade adds the following functionality to the Standard features:

  • Remotely viewing video with the following graphics resolutions:
    • Up to 1600x1200 with up to 23 bits per pixel; or
    • Up to 1920x1200 with up to 15 bits per pixel
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Remotely deploying an operating system
  • Syslog alerting
  • Redirecting serial console via SSH
  • Displaying graphics for real-time and historical power usage data and temperature

XClarity Controller Enterprise Upgrade adds the following functionality to the Advanced features:

  • Capping power usage
  • Mapping the ISO and image files located on the local client as virtual drives for use by the server
  • Mounting the remote ISO and image files via HTTPS, SFTP, CIFS, and NFS
  • Collaborating across up to six users of the virtual console
  • Controlling quality and bandwidth usage

The XClarity Controller provides remote server management through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3
  • Common Information Model (CIM)
  • Data Center Manageability Interface (DCMI) Version 1.5
  • Redfish REpresentational State Transfer (REST) API
  • Web browser with HTML5 support
  • Command-line interface
  • Virtual Operator Panel with XClarity Mobile App via the front USB port with XClarity Controller access

Virtual Operator Panel provides quick access to system status, firmware, network, health, and alerts information. With proper authentication, it also allows to configure systems management and network settings and to control system power (Power on, Power off, Restart). The Virtual Operator Panel can be accessed from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access (See Components and connectors).

Note: Depending on the system settings, the front USB port can be assigned to XClarity Controller for management functions, or to the system as a regular USB 2.0 port, or switched between two functions by using the system ID button.

The following table lists the XClarity Controller FoD upgrades.

Table 60. XClarity Controller FoD upgrades
Description Part number Feature code Maximum quantity
ThinkSystem XClarity Controller Standard to Advanced Upgrade 4L47A09132 AVUT 1
ThinkSystem XClarity Controller Standard to Enterprise Upgrade None* AUPW 1
ThinkSystem XClarity Controller Advanced to Enterprise Upgrade 4L47A09133 None** 1

* Factory-installed only.
** Field-upgrade only.

Configuration notes:

  • For factory-installed upgrades, either Standard to Advanced Upgrade (feature AVUT) or Standard to Enterprise Upgrade (feature AUPW) can be selected, but not both.
  • For field upgrades, the Advanced to Enterprise Upgrade (4L47A09133) requires the Standard to Advanced Upgrade to be activated on the server previously with either the factory-installed feature AVUT or field upgrade 4L47A09132.

Light path diagnostics

All SR630 server models include basic light path diagnostics, which provides the system LEDs on the front of the server (see Components and connectors) and the LEDs near the monitored components (for example, the DIMM error LEDs on the system board).

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator is an optional software component for the SR630. The software can be downloaded and used at no charge to discover and monitor the SR630 and to manage firmware upgrades.

If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the Lenovo XClarity software license options.

Table 61. Lenovo XClarity Pro ordering information
Part number Feature code Description
00MT201 1339 Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S
00MT202 1340 Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S
00MT203 1341 Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S
7S0X000HWW SAYV Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S
7S0X000JWW SAYW Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo systems
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.

LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 62. Lenovo XClarity Energy Manager
Part number Description
4L40E51621 Lenovo XClarity Energy Manager Node License (1 license needed per server)

For more information about XClarity Energy Manager, see the following resources:

Lenovo Capacity Planner

Lenovo Capacity Planner is a power consumption evaluation tool that enhances data center planning by enabling IT administrators and pre-sales professionals to understand various power characteristics of racks, servers, and other devices. Capacity Planner can dynamically calculate the power consumption, current, British Thermal Unit (BTU), and volt-ampere (VA) rating at the rack level, improving the planning efficiency for large scale deployments.

For more information, refer to the Capacity Planner web page:
http://datacentersupport.lenovo.com/us/en/solutions/lnvo-lcp

Security

The SR630 server offers the following security features:

  • Power-on password
  • Administrator's password
  • Secure firmware updates
  • Onboard Trusted Platform Module (TPM) version 1.2 or 2.0 (configurable UEFI system setting)
  • Trusted Cryptographic Module (TCM) (optional; PRC only)
  • Nationz Trusted Platform Module v2.0 (optional; PRC only)
  • Lockable front bezel (optional)
  • Self-encrypting drives (SEDs) with support for enterprise key managers - see the SED encryption key management section
  • Lenovo Business Vantage security software (optional; PRC only)

The server is NIST SP 800-147B compliant.

The following table lists the security options that are available for the SR630 server.

Table 63. Security options
Part number Feature code Description Maximum quantity
Lockable front bezel
7Z17A02581 AUWR ThinkSystem 1U Security Bezel 1
Trusted Cryptographic Module (PRC only)
None* AVKE ThinkSystem Trusted Cryptographic Module 1
Trusted Platform Module (PRC only)
None* B22N ThinkSystem Nationz Trusted Platform Module v2.0 1

* Factory-installed only; no field upgrade.

Lenovo Business Vantage is a security software tool suite (available only in PRC) designed to work with the TCM for enhanced security, to keep user data safe, and to erase confidential data completely from a drive.

Lenovo Business Vantage provides the following features:

  • Encrypts files to ensure data safety by using the TCM.
  • Erases confidential data from a hard disk.
  • Prohibits unauthorized access to the USB port of devices.
  • Encrypts files to ensure data security on a USB storage device.

Intel Transparent Supply Chain

Add a layer of protection in your data center and have peace of mind that the server hardware you bring into it is safe authentic and with documented, testable, and provable origin.

Lenovo has one of the world’s best supply chains, as ranked by Gartner Group, backed by extensive and mature supply chain security programs that exceed industry norms and US Government standards. Now we are the first Tier 1 manufacturer to offer Intel® Transparent Supply Chain in partnership with Intel, offering you an unprecedented degree of supply chain transparency and assurance.

To enable Intel Transparent Supply Chain for the Intel-based servers in your order, add the following feature code in the DCSC configurator, under the Security tab.

Table 64. Intel Transparent Supply Chain ordering information
Feature code Description
BB0P Intel Transparent Supply Chain

For more information on this offering, see the paper Introduction to Intel Transparent Supply Chain on Lenovo ThinkSystem Servers, available from https://lenovopress.com/lp1434-introduction-to-intel-transparent-supply-chain-on-thinksystem-servers.

Rack installation

The following table lists the rack installation options that are available for the SR630 server.

Table 65. Rack installation options
Part number Feature code Description Maximum quantity
4-post rail kits
7M27A05702 AXCA ThinkSystem Tool-less Slide Rail 1
7M27A05701 AXCB ThinkSystem Tool-less Slide Rail Kit with 1U CMA 1
4M17A07274 AXFN ThinkSystem Screw-in Slide Rail 1
4M17A07281 B0TE ThinkSystem Screw-in Slide Rail Kit with 1U CMA 1
  AXFM ThinkSystem Tool-less Friction Rail 1
4M17A07273 BK7W ThinkSystem Toolless Friction Rail v2 1
Cable management arm (CMA) upgrade
7M27A05699 None^ ThinkSystem 1U CMA Upgrade Kit for Tool-less Slide Rail 1*
4M17A07276 AXFP ThinkSystem 1U CMA Upgrade Kit for Screw-in Slide Rail 1**
Front VGA port
CTO only BMNW Front VGA Connector Upgrade Kit for 1U v2 (for 3.5" models)
CTO only AUWU ThinkSystem SR530/SR630 Front VGA Connector (for 3.5" models) 1
4Z17A80447 BMNV ThinkSystem SR530/SR570/SR630 Front VGA Connector Upgrade Kit v2 (for 2.5" models)  
7Z17A02579 AUWW ThinkSystem SR530/SR570/SR630 Front VGA Connector Upgrade Kit (for 2.5" models) 1

^ Field upgrade only.
* The CMA Upgrade Kit for Tool-less Slide Rail is supported with the Tool-less Slide Rail (7M27A05702) only.
** The CMA Upgrade Kit for Screw-in Slide Rail is supported with the Screw-in Slide Rail (4M17A07274) only.

The following table summarizes the rail kit features and specifications.

Table 66. Rail kit features and specifications summary
Feature Tool-less Slide Rail Screw-in Slide Rail Tool-less Friction Rail
Without CMA With CMA Without CMA With CMA
Part number 7M27A05702 7M27A05701 4M17A07274 4M17A07281 4M17A07273
CMA 7M27A05699 Included 4M17A07276 Included  No support
Rail length 730 mm
(28.74 in.)
807 mm
(31.8 in.)
836.8 mm
(32.9 in.)
836.8 mm
(32.9 in.)
728.1 mm
(28.7 in.)
Rail type Full-out slide (ball bearing) Full-out slide (ball bearing) Half-out slide (friction)
Tool-less installation Yes No Yes
In-rack server maintenance Yes Yes No
1U PDU support Yes Yes Yes
0U PDU support Limited* Limited* Limited**
Rack type IBM and Lenovo 4-post,
IEC standard-compliant
IBM and Lenovo 4-post,
IEC standard-compliant
IBM and Lenovo 4-post,
IEC standard-compliant
Mounting holes Square or round Square, round, or threaded Square or round
Mounting flange thickness 2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
2 mm (0.08 in.) –
3.3 mm (0.13 in.)
Distance between front
and rear mounting flanges^
609.6 mm (24 in.) –
863.6 mm (34 in.)
609.6 mm (24 in.) –
812.8 mm (32 in.)
609.6 mm (24 in.) –
863.6 mm (34 in.)

* If a 0U PDU is used, the rack cabinet must be at least 1100 mm (43.31 in.) deep if no CMA is used, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** If a 0U PDU used, the rack must be at least 1000 mm (39.37 in.) deep.
^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Operating system support

The SR630 server with 2nd Gen Intel Xeon SP processors supports the following operating systems:

  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Red Hat Enterprise Linux 7.6
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 7.9
  • Red Hat Enterprise Linux 8.0
  • Red Hat Enterprise Linux 8.1
  • Red Hat Enterprise Linux 8.2
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 8.9
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • Red Hat Enterprise Linux 9.3
  • SUSE Linux Enterprise Server 12 SP4
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP4
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen
  • SUSE Linux Enterprise Server 15 Xen SP1
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7 U1
  • VMware ESXi 6.7 U2
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0
  • VMware ESXi 7.0 U1
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

The SR630 server with 1st Gen Intel Xeon SP processors supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Microsoft Windows Server 2022
  • Microsoft Windows Server, version 1709
  • Microsoft Windows Server, version 1803
  • Red Hat Enterprise Linux 6.10 x64
  • Red Hat Enterprise Linux 6.9 x64
  • Red Hat Enterprise Linux 7.3
  • Red Hat Enterprise Linux 7.4
  • Red Hat Enterprise Linux 7.5
  • Red Hat Enterprise Linux 7.6
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 7.9
  • Red Hat Enterprise Linux 8.0
  • Red Hat Enterprise Linux 8.1
  • Red Hat Enterprise Linux 8.2
  • Red Hat Enterprise Linux 8.3
  • Red Hat Enterprise Linux 8.4
  • Red Hat Enterprise Linux 8.5
  • Red Hat Enterprise Linux 8.6
  • Red Hat Enterprise Linux 8.7
  • Red Hat Enterprise Linux 8.8
  • Red Hat Enterprise Linux 9.0
  • Red Hat Enterprise Linux 9.1
  • Red Hat Enterprise Linux 9.2
  • SUSE Linux Enterprise Server 11 Xen x64 SP4
  • SUSE Linux Enterprise Server 11 x64 SP4
  • SUSE Linux Enterprise Server 12 SP2
  • SUSE Linux Enterprise Server 12 SP3
  • SUSE Linux Enterprise Server 12 SP4
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP2
  • SUSE Linux Enterprise Server 12 Xen SP3
  • SUSE Linux Enterprise Server 12 Xen SP4
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 SP2
  • SUSE Linux Enterprise Server 15 SP3
  • SUSE Linux Enterprise Server 15 SP4
  • SUSE Linux Enterprise Server 15 SP5
  • SUSE Linux Enterprise Server 15 Xen
  • SUSE Linux Enterprise Server 15 Xen SP1
  • SUSE Linux Enterprise Server 15 Xen SP2
  • SUSE Linux Enterprise Server 15 Xen SP3
  • SUSE Linux Enterprise Server 15 Xen SP4
  • SUSE Linux Enterprise Server 15 Xen SP5
  • Ubuntu 22.04 LTS 64-bit
  • VMware ESXi 6.0 U3
  • VMware ESXi 6.5
  • VMware ESXi 6.5 U1
  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7
  • VMware ESXi 6.7 U1
  • VMware ESXi 6.7 U2
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0
  • VMware ESXi 7.0 U1
  • VMware ESXi 7.0 U2
  • VMware ESXi 7.0 U3
  • VMware ESXi 8.0
  • VMware ESXi 8.0 U1
  • VMware ESXi 8.0 U2

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=sr630-7x01-7x02-sp-gen-2

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 67. VMware ESXi preload
Part number Feature code Description
CTO only B3VW VMware ESXi 6.5 U2 (Factory Installed)
CTO only B6U0 VMware ESXi 6.5 U3 (factory installed)
CTO only B3VX VMware ESXi 6.7 (Factory Installed)
CTO only B4XA VMware ESXi 6.7 U1 (Factory Installed)
CTO only B6U1 VMware ESXi 6.7 U2 (factory installed)
CTO only B88T VMware ESXi 6.7 U3 (factory installed)
CTO only BBZG VMware ESXi 7.0 (Factory Installed)
CTO only BE5E VMware ESXi 7.0 U1 (Factory Installed)
CTO only BHSR VMware ESXi 7.0 U2 (Factory Installed)
CTO only BMEY VMware ESXi 7.0 U3 (Factory Installed)
CTO only BMT5 VMware ESXi 8.0 (Factory Installed)
CTO only BQ8S VMware ESXi 8.0 U1 (Factory Installed)
CTO only BYC7 VMware ESXi 8.0 U2 (Factory Installed)

Physical and electrical specifications

The SR630 has the following overall physical dimensions, excluding components that extend outside the standard chassis, such as EIA flanges, front security bezel (if any), and power supply handles:

  • Width: 435 mm (17.1 inches)
  • Height: 43 mm (1.7 inches)
  • Depth: 750 mm (29.5 inches)

The following table lists the detailed dimensions. See the figure below for the definition of each dimension.

Table 68. Detailed dimensions
Dimension Description
482 mm Xa = Width, to the outsides of the front EIA flanges
435 mm Xb = Width, to the rack rail mating surfaces
435 mm Xc = Width, to the outer most chassis body feature
43 mm Ya = Height, from the bottom of chassis to the top of the chassis
715 mm Za = Depth, from the rack flange mating surface to the rearmost I/O port surface
716 mm Zb = Depth, from the rack flange mating surface to the rearmost feature of the chassis body
744 mm Zc = Depth, from the rack flange mating surface to the rearmost feature such as power supply handle
35 mm Zd = Depth, from the forwardmost feature on front of EIA flange to the rack flange mating surface
47 mm Ze = Depth, from the front of security bezel (if applicable) or forwardmost feature to the rack flange mating surface

Rack server dimensions
Figure 10. Server dimensions

The shipping dimensions (cardboard packaging) of the SR630 are as follows:

  • Width: 587 mm (23.1 inches)
  • Height: 225 mm (8.9 inches)
  • Depth: 998 mm (39.3 inches)

The server has the following weight:

  • Minimum configuration: 11.9 kg (26.2 lb)
  • Maximum configuration: 18.8 kg (41.4 lb)

Electrical specifications for AC power supplies:

  • 100 - 127 (nominal) V AC; 50 Hz / 60 Hz
  • 200 - 240 (nominal) V AC; 50 Hz / 60 Hz
  • 180 - 300 V DC (HVDC; supported in PRC only)

Power load and inlet current

The following table lists the maximum system power load, rated inlet current, and system heat output based on the power supply and source voltage.

Table 69. Rated system power, inlet current, and system heat output
Power supply Source voltage Maximum power
load per system
(two power supplies)
Rated current
per inlet
System
heat output
550 W Platinum 100 - 127 V AC 722 W 6.2 A 2463 BTU/hour
200 - 240 V AC 704 W 3 A 2402 BTU/hour
180 - 300 V DC 702 W 2.5 A 2395 BTU/hour
750 W Platinum 100 - 127 V AC 984 W 8.4 A 3357 BTU/hour
200 - 240 V AC 958 W 4.1 A 3269 BTU/hour
180 - 300 V DC 958 W 3.5 A 3269 BTU/hour
750 W Titanium 200 - 240 V AC 949 W 4.1 A 3238 BTU/hour
180 - 300 V DC 948 W 3.5 A 3235 BTU/hour
1100 W Platinum 100 - 127 V AC 1382 W 12 A 4715 BTU/hour
200 - 240 V AC 1408 W 6 A 4804 BTU/hour
180 - 300 V DC 1408 W 5.1 A 4804 BTU/hour

Operating environment

The SR630 server complies with ASHRAE class A2 specifications. The server performance might be impacted when the operating temperature is outside the ASHRAE A2 specifications. Depending on the hardware configuration, some server models comply with ASHRAE class A3 and class A4 specifications. To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements at the same time:

  • Two power supplies installed
  • Persistent memory modules not installed
  • NVMe drives not installed
  • NVMe PCIe flash adapters not installed
  • Graphic processing units (GPUs) not installed
  • Processors with TDP more than or equal to 150 W not installed
  • For 8x 2.5" and 10x 2.5" chassis only: A maximum of one supercapacitor module installed

Temperature and humidity

The SR630 server is supported in the following environment:

  • Air temperature:
    • Operating:
      • ASHRAE Class A4: 5 °C - 45 °C (41 °F - 113 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 125-m (410-ft) increase in altitude
      • ASHRAE Class A3: 5 °C - 40 °C (41 °F - 104 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 175-m (574-ft) increase in altitude
      • ASHRAE Class A2: 10 °C - 35 °C (50 °F - 95 °F); for altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C for every 300-m (984-ft) increase in altitude
    • Non-operating: 5 °C - 45 °C (41 °F - 113 °F)
    • Storage: -40 °C - +60 °C (-40 °F - 140 °F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Humidity:
    • Operating:
      • ASHRAE Class A4: 8% - 90% (non-condensing); maximum dew point: 24 °C (75 °F)
      • ASHRAE Class A3: 8% - 85% (non-condensing); maximum dew point: 24 °C (75 °F)
      • ASHRAE Class A2: 8% - 80% (non-condensing); maximum dew point: 21 °C (70 °F)
    • Storage: 8% - 90% (non-condensing)

Acoustical noise emissions

The server has the following acoustic noise emissions declaration:

  • Minimum configuration:
    • Operating: 5.3 bels
    • Idle: 4.9 bels
  • Maximum configuration:
    • Operating: 6.0 bels
    • Idle: 5.8 bels

Shock and vibration

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Particulate contamination

Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might damage the system that might cause the system to malfunction or stop working altogether.

The following specifications indicate the limits of particulates that the system can tolerate:

  • Reactive gases:
    • The copper reactivity level shall be less than 200 Angstroms per month (Å/month)
    • The silver reactivity level shall be less than 200 Å/month
  • Airborne particulates:
    • The room air should be continuously filtered with MERV 8 filters.
    • Air entering a data center should be filtered with MERV 11 or preferably MERV 13 filters.
    • The deliquescent relative humidity of the particulate contamination should be more than 60% RH
    • Environment must be free of zinc whiskers

For additional information, see the Specifications section of the documentation for the server, available from the Lenovo Documents site, https://pubs.lenovo.com/

Warranty and support

The SR630 server has a one-year (7X01) or three-year (Machine Type 7X02) warranty.

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:

  • Premier Support

    Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:

    • Direct technician-to-technician access through a dedicated phone line
    • 24x7x365 remote support
    • Single point of contact service
    • End to end case management
    • Third-party collaborative software support
    • Online case tools and live chat support
    • On-demand remote system analysis
  • Warranty Upgrade (Preconfigured Support)

    Services are available to meet the on-site response time targets that match the criticality of your systems.

    • 3, 4, or 5 years of service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.

  • Enterprise Server Software Support

    Enterprise Software Support is an additional support service providing customers with software support on Microsoft, Red Hat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Services

Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Here’s a more in-depth look at what we can do for you:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.

Regulatory compliance

The ThinkSystem SR630 server conforms to the following regulations:

  • United States: FCC Part 15, Class A; UL 60950-1
  • Canada: ICES-003/NMB-03, Class A; CAN/CSA-C22.2 60950-1
  • Mexico: NOM-19
  • Argentina: IEC60950-1
  • European Union: CE Mark (EN55022 Class A, IEC/EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
  • Germany: TUV-GS (IEC/EN 60950-1, EK1-ITB2000)
  • Russia, Kazakhstan, Belarus: EAC (TR CU 004/2011, TR CU 020/2011)
  • China: CCC GB4943.1, GB9254 Class A, GB17625.1
  • India: BIS
  • Japan: VCCI, Class A
  • Taiwan: BSMI CNS13438, Class A; CNS14336-1
  • Korea: KN22, Class A; KN24
  • Australia/New Zealand: AS/NZS CISPR 22 Class A
  • Reduction of Hazardous Substances (ROHS)
  • Energy Star 3.0 (excluding configurations with Bronze 3204, Gold 5222, or Platinum 8256 processors)

Note: For more information on the Energy Star 3.0 certification, refer to the Energy Star 3.0 Certifications for ThinkSystem Servers publication:
http://lenovopress.com/lp1230

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 70. External drive enclosures
Model Description
4587HC1 Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays)
4587HC2 Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays)
6413HC1 Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays)
7DAHCTO1WW Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays)

For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The following table lists the external backup options that are offered by Lenovo.

Table 71. External backup options
Part number Description
External RDX USB drives
4T27A10725 ThinkSystem RDX External USB 3.0 Dock
External SAS tape backup drives
6160S7E IBM TS2270 Tape Drive Model H7S
6160S8E IBM TS2280 Tape Drive Model H8S
6160S9E IBM TS2290 Tape Drive Model H9S
External SAS tape backup autoloaders
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS
6171S9R IBM TS2900 Tape Autoloader w/LTO9 HH SAS
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
6741A3F IBM TS4300 3U Tape Library-Expansion Unit
Full High 8 Gb Fibre Channel for TS4300
01KP938 LTO 7 FH Fibre Channel Drive
01KP954 LTO 8 FH Fibre Channel Drive
02JH837 LTO 9 FH Fibre Channel Drive
Half High 8 Gb Fibre Channel for TS4300
01KP936 LTO 7 HH Fibre Channel Drive
01KP952 LTO 8 HH Fibre Channel Drive
02JH835 LTO 9 HH Fibre Channel Drive
Half High 6 Gb SAS for TS4300
01KP937 LTO 7 HH SAS Drive
01KP953 LTO 8 HH SAS Drive
02JH836 LTO 9 HH SAS Drive

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

Ethernet LAN switches

The following table lists the Ethernet LAN switches that are offered by Lenovo that can be used with the ThinkSystem SR630 server for network connectivity.

Table 72. Ethernet LAN switches
Description Part number
1 Gb Ethernet switches
Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front) 7Y810011WW
Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE) 7Z320O11WW
Lenovo RackSwitch G7028 (Rear to Front) 7159BAX
Lenovo RackSwitch G7052 (Rear to Front) 7159CAX
Lenovo CE0128TB Switch (3-Year Warranty) 7Z340011WW
Lenovo CE0128TB Switch (Limited Lifetime Warranty) 7Z360011WW
Lenovo CE0128PB Switch (3-Year Warranty) 7Z340012WW
Lenovo CE0128PB Switch (Limited Lifetime Warranty) 7Z360012WW
Lenovo CE0152TB Switch (3-Year Warranty) 7Z350021WW
Lenovo CE0152TB Switch (Limited Lifetime Warranty) 7Z370021WW
Lenovo CE0152PB Switch (3-Year Warranty) 7Z350022WW
Lenovo CE0152PB Switch (Limited Lifetime Warranty) 7Z370022WW
10 Gb Ethernet switches
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) 7159A1X
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) 7159B1X
Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE) 7Z330O11WW
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) 7159C1X
Lenovo RackSwitch G8272 (Rear to Front) 7159CRW
25 Gb Ethernet switches
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) 7159E1X
Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE) 7Z210O21WW
Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE) 7Z330O21WW
100 Gb Ethernet switches
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) 7159D1X
Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE) 7Z210O11WW

For more information, see the list of Product Guides in the Top-of-rack Switches category:
http://lenovopress.com/servers/options/switches#rt=product-guide

Fibre Channel SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Rack cabinets

The following table lists the supported rack cabinets.

Table 73. Rack cabinets
Part number Description
7D2B0001WW / 7D2N0001WW 12U 1200mm Deep Micro Datacenter Rack
7D2C0001WW / 7D2P0001WW 18U 1200mm Deep Micro Datacenter Rack
93072RX 25U Standard Rack (1000mm)
93072PX 25U Static S2 Standard Rack (1000mm)
7D6DA007WW ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6DA008WW ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O42 Lenovo EveryScale 42U Onyx Heavy Duty Rack Cabinet
1410-P42 Lenovo EveryScale 42U Pearl Heavy Duty Rack Cabinet
93604PX 42U 1200mm Deep Dynamic Rack
93614PX 42U 1200mm Deep Static Rack
93634PX 42U 1100mm Dynamic Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93074RX 42U Standard Rack (1000mm)
7D6EA009WW ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)
7D6EA00AWW ThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)
1410-O48 Lenovo EveryScale 48U Onyx Heavy Duty Rack Cabinet
1410-P48 Lenovo EveryScale 48U Pearl Heavy Duty Rack Cabinet

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM switches and consoles

The following table lists the supported KVM consoles.

Table 74. KVM console
Part number Description
Consoles
4XF7A84188 ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009 ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX 1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 75. Keyboards for 1U 18.5" Standard Console
Part number Description
7ZB7A05469 ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 76. KVM switches and options
Part number Description
KVM Console switches
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option Pack
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 77. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 78. Uninterruptible power supply units
Part number Description
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region-specific offers, please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/

Seller training courses

The following sales training courses are offered for employees and partners (login required). Courses are listed in date order.

  1. Partner Technical Webinar - ISG Portfolio Update
    2024-04-15 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - ISG Portfolio Update

    In this 60-minute replay, Mark Bica, NA ISG Server Product Manager reviewed the Lenovo ISG portfolio. He covered new editions such as the SR680a \ SR685a, dense servers, and options that are strategic for any workload.

    Published: 2024-04-15
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 041224
  2. Partner Technical Webinar – StorMagic
    2024-03-19 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar – StorMagic

    March 08, 2024 – In this 60-minute replay, Stuart Campbell and Wes Ganeko of StorMagic joined us and provided an overview of StorMagic on Lenovo. They also demonstrated the interface while sharing some interesting use cases.

    Published: 2024-03-19
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 030824
  3. Intel Transparent Supply Chain on Lenovo Servers
    2024-01-29 | 12 minutes | Employees and Partners
    Details
    Intel Transparent Supply Chain on Lenovo Servers

    This course introduces the Intel Transparent Supply Chain (TSC) program, explains how the program works, and discusses the benefits of the Intel TSC program to customers. Adding the Intel TSC feature to an order is explained.

    Course objectives:
    • Describe the Intel® Transparent Supply Chain program
    • Explain how the Intel® Transparent Supply Chain program works
    • Discuss the benefits of the Intel® Transparent Supply Chain program to Lenovo customers
    • Explain how to add Intel® Transparent Supply Chain program feature to an order

    Published: 2024-01-29
    Length: 12 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1230
  4. Family Portfolio: Storage Controller Options
    2024-01-23 | 25 minutes | Employees and Partners
    Details
    Family Portfolio: Storage Controller Options

    This course covers the storage controller options available for use in Lenovo servers. The classes of storage controller are discussed, along with a discussion of where they are used, and which to choose.

    After completing this course, you will be able to:
    • Describe the classes of storage controllers
    • Discuss where each controller class is used
    • Describe the available options in each controller class

    Published: 2024-01-23
    Length: 25 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1111
  5. Lenovo-Intel Sustainable Solutions QH
    2024-01-22 | 10 minutes | Employees and Partners
    Details
    Lenovo-Intel Sustainable Solutions QH

    This Quick Hit explains how Lenovo and Intel are committed to sustainability, and introduces the Lenovo-Intel joint sustainability campaign. You will learn how to use this campaign to show customers what that level of commitment entails, how to use the campaign's unsolicited proposal approach, and how to use the campaign as a conversation starter which may lead to increased sales.

    Published: 2024-01-22
    Length: 10 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2524a
  6. Family Introduction: Rack and Tower
    2024-01-19 | 11 minutes | Employees and Partners
    Details
    Family Introduction: Rack and Tower

    This course is designed to give Lenovo sales and partner representatives a foundation on the characteristics of the rack and tower server family. As an introduction to the family, this course also includes positioning, when to use a product, and keywords a client may use when discussing a rack product.

    Course Objectives:
    • Family Characteristics
    • Priority Positioning
    • Product Usage
    • Keywords and Phrases

    Published: 2024-01-19
    Length: 11 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1100r3
  7. FY24Q3 Intel Servers Update
    2023-12-11 | 15 minutes | Employees and Partners
    Details
    FY24Q3 Intel Servers Update

    This update is designed to help you discuss the features and customer benefits of Lenovo servers that use the 5th Gen Intel® Xeon® processors. Lenovo has also introduced a new server, the ThinkSystem SD650-N V3, which expands the supercomputer server family. Reasons to call your customer and talk about refreshing their infrastructure are also included as a guideline.

    Published: 2023-12-11
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2522a
  8. Family Portfolio: Intel Rack and Tower Servers
    2023-12-11 | 15 minutes | Employees and Partners
    Details
    Family Portfolio: Intel Rack and Tower Servers

    This course is designed to give Lenovo sales and partner representatives a foundation of the ThinkSystem Intel Rack and Tower server family. After completing this course, you will be able to identify products and features within the ThinkSystem Intel rack and tower server family, describe unique innovations that this product family uses and recognize when a specific product should be selected.

    Published: 2023-12-11
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1204r11
  9. Partner Technical Webinar - Cloudian - Ransomware
    2023-10-12 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Cloudian - Ransomware

    In this 60-minute replay, Tim O’Neal, Eric Craig, and Charlii Collins of Cloudian discuss how Cloudian protects from Ransomware paired with VEEAM, Commvault, or Rubrik.

    Published: 2023-10-12
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 100623
  10. Lenovo Data Center Product Portfolio
    2023-07-21 | 15 minutes | Employees and Partners
    Details
    Lenovo Data Center Product Portfolio

    This course introduces the Lenovo data center portfolio, and covers servers, storage, storage networking, and software-defined infrastructure products. After completing this course about Lenovo data center products, you will be able to identify product types within each data center family, describe Lenovo innovations that this product family or category uses, and recognize when a specific product should be selected.

    Published: 2023-07-21
    Length: 15 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1110r6
  11. Partner Technical Webinar - Data Center Limits and ISG TAA Compliance
    2023-05-16 | 60 minutes | Employees and Partners
    Details
    Partner Technical Webinar - Data Center Limits and ISG TAA Compliance

    In this 60-minute replay, we had two topics. First Vinod Kamath, Lenovo Distinguished Engineer for Data Center Cooling presented on the Systems Configuration and Data Center Ambient Limits. Second, Shama Patari, Lenovo Trade Council, and Glenn Johnson, Lenovo Principal Engineer for Supply Chain presented on ISG TAA Compliance.

    Published: 2023-05-16
    Length: 60 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: 051223
  12. Family Portfolio: Edge Solutions
    2022-12-06 | 10 minutes | Employees and Partners
    Details
    Family Portfolio: Edge Solutions

    This course describes the Lenovo edge solutions. Edge servers, such as the Lenovo ThinkSystem SE350 and ThinkEdge SE450, are used at the edge of an IoT environment, and may be part of an edge solution. Solutions such as those using software from Scale Computing typically use more traditional Lenovo servers.
    After completing this course, you will be able to list the edge solutions in the Lenovo portfolio, describe the features of each solution and determine which solution is best suited to a specific environment.

    Published: 2022-12-06
    Length: 10 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW1108r4
  13. Lenovo Sustainable Computing
    2022-09-16 | 4 minutes | Employees and Partners
    Details
    Lenovo Sustainable Computing

    This Quick Hit describes the Lenovo sustainable computing program, and the many ways in which Lenovo strives to respect and protect the environment.

    Published: 2022-09-16
    Length: 4 minutes
    Employee link: Grow@Lenovo
    Partner link: Lenovo Partner Learning
    Course code: SXXW2504a

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
Bootable Media Creator
Flex System
Lenovo Services
RackSwitch
System x®
ThinkServer®
ThinkSystem®
TopSeller
TruDDR4
UpdateXpress System Packs
XClarity®

The following terms are trademarks of other companies:

Intel®, Intel Optane™, and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

SPECpower® is a trademark of the Standard Performance Evaluation Corporation (SPEC).

Other company, product, or service names may be trademarks or service marks of others.