ThinkSystem M.2 Drives and M.2 AdaptersProduct Guide
Abstract
M.2 is a solid-state drive (SSD) form factor primarily used as an operating system boot solution. Lenovo ThinkSystem servers support M.2 drives either with the addition of a supported M.2 adapter or module, or directly on the system board.
This product guide provides essential presales information to understand the ThinkSystem M.2 offerings, their key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the M.2 components, and consider their use in IT solutions.
Change History
Changes in the December 3 update:
- New SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit, 4M17A37606
Human Factors Engineer Tim Meserth shows the Lenovo M.2 solution
Introduction
M.2 is a solid-state drive (SSD) form factor primarily used as an operating system boot solution however depending on the endurance of the M.2 drives, they may also be suitable for read-intensive or mixed workloads.
Lenovo ThinkSystem servers support M.2 drives in one of three ways, depending on the server selected:
- One or two drives, mounted in an M.2 adapter, vertically in a dedicated slot
- Two or four drives, mounted horizontally in an M.2 adapter
- Installed directly on the system board
One example is the Dual M.2 Adapter, as shown in the following figure, with one 128GB M.2 drive partially inserted. The second M.2 drive is installed on the other side of the adapter.
Figure 1. Dual M.2 Adapter and a 128 GB M.2 drive
Did you know?
The Dual M.2 Adapter features a Lenovo patented design that provides a tool-less method for attaching back-to-back M.2 modules to the adapter.
The Dual M.2 Adapter and SATA RAID M.2 Module include a built-in RAID controller and allows two installed M.2 drives to be configured either as RAID-1, RAID-0, or two independent drives (JBOD mode).
Part number information
The following tables list the ThinkSystem part numbers.
Part number |
Feature code |
Description |
---|---|---|
M.2 adapters (ThinkSystem servers with Intel Xeon Scalable processors) | ||
7Y37A01092 | AUMU | ThinkSystem M.2 Enablement Kit (contains the Single M.2 Adapter; supports 1 drive) |
7Y37A01093 | AUMV | ThinkSystem M.2 with Mirroring Enablement Kit (contains the Dual M.2 Adapter, supports 1 or 2 drives with RAID) |
4M17A60519 | B88P | ThinkSystem SE350 M.2 Mirroring Enablement Kit (contains the Dual M.2 Adapter, supports 1 or 2 drives with RAID) |
M.2 modules (SR635 and SR655 only) | ||
4Y37A09739 | B5XH | ThinkSystem M.2 SATA 2-Bay RAID Enablement Kit (supports 2 SATA drives with RAID) |
4Y37A09738 | B5XJ | ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit (supports 2 SATA or 2 NVMe drives, no RAID) |
M.2 adapter (SE350 only) | ||
4M17A37281 | B6FF | ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit (supports 4 SATA or 4 NVMe drives, no RAID) |
4M17A37606 | B6FG | ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit (supports 4 SATA drives with RAID) |
M.2 thermal kit (some servers) | ||
4XH7A08791 | B31F | ThinkSystem M.2 480GB SSD Thermal Kit (contains an air baffle required by some server configurations) |
Part number |
Feature code |
Description |
---|---|---|
SATA drives | ||
7N47A00129 | AUUL | ThinkSystem M.2 32GB SATA 6Gbps Non-Hot-Swap SSD |
7N47A00130 | AUUV | ThinkSystem M.2 128GB SATA 6Gbps Non-Hot-Swap SSD |
Micron 5100 SATA drives (non-SED) | ||
4XB7A14049 | B5S4 | ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD |
7SD7A05703 | B11V | ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot-Swap SSD |
4XB7A14048 | B5UP | ThinkSystem M.2 5100 960GB SATA 6Gbps Non-Hot Swap SSD |
4XB7A39425 | B75B | ThinkSystem M.2 1.92TB 5100 Pro SATA 6Gbps Non-Hot Swap SSD |
Micron 5100 SATA SED drives (TCG-e encryption) | ||
4XB7A37273 | B6FM | ThinkSystem M.2 480GB 5100 Pro SATA 6Gbps Non-Hot Swap SED SSD |
4XB7A37274 | B6FN | ThinkSystem M.2 960GB 5100 Pro SATA 6Gbps Non-Hot Swap SED SSD |
4XB7A37275 | B6FP | ThinkSystem M.2 1.92TB 5100 Pro SATA 6Gbps Non-Hot Swap SED SSD |
ATP A600i Industrial SATA drives (non-SED) | ||
4XB7A39422 | B758 | ThinkSystem M.2 120GB Industrial A600i SATA SSD |
4XB7A39423 | B759 | ThinkSystem M.2 480GB Industrial A600i SATA SSD |
4XB7A39424 | B75A | ThinkSystem M.2 800GB Industrial A600i SATA SSD |
ATP A600i Industrial SATA SED drives (Opal encryption) | ||
4XB7A37270 | B6FT | ThinkSystem M.2 120GB Industrial A600i SATA SED SSD |
4XB7A37271 | B6FK | ThinkSystem M.2 480GB Industrial A600i SATA SED SSD |
4XB7A37272 | B6FL | ThinkSystem M.2 800GB Industrial A600i SATA SED SSD |
Intel P4511 SATA drives (non-SED) | ||
4XB7A37276 | B6FQ | ThinkSystem SE350 Edge Server - M.2 650GB P4511 NVMe High Endurance SSD |
4XB7A37277 | B6FR | ThinkSystem SE350 Edge Server - M.2 1TB P4511 NVMe SSD |
4XB7A37278 | B6FS | ThinkSystem SE350 Edge Server - M.2 2TB P4511 NVMe SSD |
Intel P4511 SATA SED drives (Opal encryption) | ||
4XB7A39426 | B75C | ThinkSystem M.2 650GB P4511 NVMe SED High Endurance SSD |
4XB7A39427 | B75D | ThinkSystem M.2 1TB P4511 NVMe SED SSD |
4XB7A39428 | B75E | ThinkSystem M.2 2TB P4511 NVMe SED SSD\ |
Implementation
Implementation of M.2 in ThinkSystem servers is one of four ways:
- On the ThinkSystem SR150, SR250 and ST250, a single M.2 drive is installed directly on the system board.
- On ThinkSystem servers, including the SE350 and those servers with first or second-generation Intel Xeon Scalable processors, the M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot in the server. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy. There are two M.2 adapters supported:
- Single M.2 Adapter, which supports one M.2 drive; available as the ThinkSystem M.2 Enablement Kit
- Dual M.2 Adapter, which supports one or two M.2 drives; available as the ThinkSystem M.2 with Mirroring Enablement Kit. Includes a built-in RAID controller and allows two installed M.2 drives to be configured either as RAID-1, RAID-0, or two independent drives (JBOD mode).
The Single M.2 Adapter is shown in the following photo, with the 32GB M.2 drive installed.
Figure 2. Single M.2 Adapter and a 32 GB M.2 drive - On the SR655 and SR635, an M.2 module is mounted horizontally and is cabled to the system board. There are two M.2 modules offered:
- SATA RAID M.2 Module, which supports two SATA M.2 drives and supports RAID functionality; available as the ThinkSystem M.2 SATA 2-Bay RAID Enablement Kit
- SATA/NVMe M.2 Module, which supports two SATA or two NVMe M.2 drives (no RAID); available as the ThinkSystem M.2 SATA/NVMe 2-Bay Enablement Kit
The following figure shows the SATA/NVMe M.2 Module with two 128 GB M.2 drives installed. Note that the production M.2 Module has a green circuit board, not the red color as shown here.
Figure 3. SATA/NVMe M.2 Module with 2 drives - On the ThinkSystem SE350 edge server, the M.2 data drives are mounted on a 4-drive adapter that plugs into the PCIe riser. There are two M.2 modules offered:
- ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit, which supports four SATA or four NVMe M.2 drives without RAID support
- ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit, which supports four SATA drives and supports RAID 0/1 functionality
Tip: The M.2 adapters and modules are also referred to as enablement kits. In the product publications, they are referred to as M.2 backplanes. These terms are interchangable.
Features
Features of the ThinkSystem M.2 solution:
- Hardened boot media that does not use a drive bay
- Both mechanically & electronically designed to be more robust than any prior implementation
- Design provides hardware mirroring of two M.2 SSDs
- M.2 SSDs have higher mean time between failures (MTBF) than SD cards or USB keys
- Tool-less clip design that supports back to back connector layout, providing simple install in limited space.
- When using configure-to-order (CTO), you can also select zero drives and add drives as a field upgrade.
Features of the Dual M.2 Adapter:
- PCIe 2.0 x2 host interface (connects to the PCH)
- Based on the Marvell 88SE9230 6 Gbps SATA controller
- Supports one or two 6 Gbps SATA M.2 drives
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280 respectively)
- RAID functionality provided by the M.2 adapter
- RAID 1 by default; also supports RAID 0 and JBOD
- UEFI-based settings to enable/disable RAID mode and to review inventory
- Supports Secure Boot
- Adapter and drive firmware update using Lenovo firmware tools
- Management via I2C interface
Features of the Single M.2 Adapter:
- 6 Gbps SATA host interface (connects to the PCH)
- Supports one 6 Gbps SATA M.2 drive
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280 respectively)
- Drive firmware update using Lenovo firmware tools
- Management via I2C interface
- VPD reporting of adapter inventory
The SATA RAID Enablement Kit for the SR635 and SR655 has the following features:
- Supports one or two SATA M.2 drives
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280 respectively)
- RAID support via an onboard Marvell 88SE9230 SATA RAID Controller
- Support JBOD, RAID-0 and RAID-1 (RAID support requires two M.2 drives)
- PCIe 2.0 x2 host interface; 6Gbps SATA connection to the drives
- Management and configuration support via UEFI and OS-based tools
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
The SATA/NVMe Enablement Kit for the SR635 and SR655 has the following features:
- Supports one or two M.2 drives, either SATA or NVMe
- When two drives installed, they must be either both SATA or both NVMe
- Support 42mm, 60mm and 80mm drive form factors (2242, 2260 and 2280 respectively)
- JBOD support only; no RAID support
- Either 6Gbps SATA or PCIe 3.0 x4 interface to the drives depending on the drives installed
- Supports monitoring and reporting of events and temperature through I2C
- Firmware update via Lenovo firmware update tools
The ThinkSystem SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit has the following features:
- Supports four SATA or four NVMe M.2 drives (no mixing of drive types)
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110 respectively)
- For SATA drives, RAID 0, 1, 5, 10, provided by the PCH controller in the processor
- For NVMe, JBOD support only; no RAID support
- Either 6Gbps SATA or PCIe 3.0 x4 interface to the drives depending on the drives installed
The ThinkSystem SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit has the following features:
- Supports four SATA M.2 drives (NVMe drives not supported)
- Support 42mm, 60mm, 80mm and 110mm drive form factors (2242, 2260, 2280 and 22110 respectively)
- RAID support via two independent Marvell 88SE9230 6 Gbps SATA controllers
- Each controller connects to two M.2 drives, offering RAID-0 or RAID-1
Tip: 2242, 2260, 2280 and 22110 are the industry terms for the M.2 drive dimensions. For example, 2280 corresponds to a drive that is 22mm wide and 80mm long.
Technical specifications of the drives
The following table compares the performance specifications of the M.2 drives
Part number |
Description | Endurance DWPD |
Endurance TBW |
IOPS reads |
IOPS writes |
Sequential read rate |
Sequential write rate |
Read latency |
Write latency |
---|---|---|---|---|---|---|---|---|---|
Lite-On | |||||||||
7N47A00129 | 32GB SATA (CV1) | 0.66 DWPD | 37.92TB | 25,000 IOPS | 10,500 IOPS | 260 MB/s | 40 MB/s | N/A | N/A |
7N47A00130 | 128GB SATA (CV8) | 0.28 DWPD | 63.9 TB | 42,000 IOPS | 2,300 IOPS | 500 MB/s | 140 MB/s | N/A | N/A |
Micron 5100 (Non-SED) | |||||||||
4XB7A14049 | 5100 240 GB SATA | 1.5 DWPD | 650 TB | 78,000 IOPS | 26,000 IOPS | 540 MB/s | 250 MB/s | 500 µs | 500 µs |
7SD7A05703 | 5100 480GB SATA | 1.5 DWPD | 1,300 TB | 93,000 IOPS | 43,000 IOPS | 540 MB/s | 410 MB/s | 500 µs | 500 µs |
4XB7A14048 | 5100 960GB SATA | 2.5 DWPD | 4,400 TB | 93,000 IOPS | 37,000 IOPS | 540 MB/s | 520 MB/s | 500 µs | 500 µs |
4XB7A39425 | 1.92TB 5100 SATA | 2.5 DWPD | 8,800 TB | 93,000 IOPS | 37,000 IOPS | 540 MB/s | 520 MB/s | 500 µs | 500 µs |
Micron 5100 SED (TCP-e Encryption) | |||||||||
4XB7A37273 | 480GB 5100 SATA SED | 1.5 DWPD | 1,300 TB | 93,000 IOPS | 43,000 IOPS | 540 MB/s | 410 MB/s | 500 µs | 500 µs |
4XB7A37274 | 960GB 5100 SATA SED | 2.5 DWPD | 4,400 TB | 93,000 IOPS | 37,000 IOPS | 540 MB/s | 520 MB/s | 500 µs | 500 µs |
4XB7A37275 | 1.92TB 5100 SATA SED | 2.5 DWPD | 8,800 TB | 93,000 IOPS | 37,000 IOPS | 540 MB/s | 520 MB/s | 500 µs | 500 µs |
ATP Industrial A600i (non-SED) | |||||||||
4XB7A39422 | 120GB A600i SATA | 0.2 DWPD | 48 TB | 45,000 IOPS | 32,500 IOPS | 560 MB/s | 125 MB/s | N/A | N/A |
4XB7A39423 | 480GB A600i SATA | 0.4 DWPD | 384 TB | 100,200 IOPS | 82,800 IOPS | 560 MB/s | 390 MB/s | N/A | N/A |
4XB7A39424 | 800GB A600i SATA | 0.5 DWPD | 768 TB | 97,400 IOPS | 78,600 IOPS | 560 MB/s | 370 MB/s | N/A | N/A |
ATP Industrial A600i SED (Opal Encryption) | |||||||||
4XB7A37270 | 120GB A600i SATA SED | 0.2 DWPD | 48 TB | 45,000 IOPS | 32,500 IOPS | 560 MB/s | 125 MB/s | N/A | N/A |
4XB7A37271 | 480GB A600i SATA SED | 0.4 DWPD | 384 TB | 100,200 IOPS | 82,800 IOPS | 560 MB/s | 390 MB/s | N/A | N/A |
4XB7A37272 | 800GB A600i SATA SED | 0.5 DWPD | 768 TB | 97,400 IOPS | 78,600 IOPS | 560 MB/s | 370 MB/s | N/A | N/A |
Intel P4511 SED (Opal Encryption) | |||||||||
4XB7A39426 | 650GB P4511 NVMe SED | 3.0 DWPD | 3900 TB | 295,000 IOPS | 31,000 IOPS | 2000 MB/s | 1050 MB/s | 85 µs | 40 µs |
4XB7A39427 | 1TB P4511 NVMe SED | 0.5 DWPD | 980 TB | 295,000 IOPS | 31,000 IOPS | 2000 MB/s | 1050 MB/s | 85 µs | 40 µs |
4XB7A39428 | 2TB P4511 NVMe SED | 0.5 DWPD | 1950 TB | 295,000 IOPS | 36,000 IOPS | 2000 MB/s | 1050 MB/s | 85 µs | 40 µs |
Server support
The following table lists the servers that are compatible.
Description and part number number |
E | 1S Intel | 2S Intel | AMD | 4S Intel | Dense/ Blade | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE350 (7Z46 / 7D1X)
|
ST50 (7Y48/7Y50)
|
ST250 (7Y45/7Y46)
|
SR150 (7Y54)
|
SR250 (7Y51/7Y52)
|
ST550 (7X09/7X10)
|
SR530 (7X07/7X08)
|
SR550 (7X03/7X04)
|
SR570 (7Y02/7Y03)
|
SR590 (7X98/7X99)
|
SR630 (7X01/7X02)
|
SR650 (7X05/7X06)
|
SR670 (7Y36/7Y37/7Y38)
|
SR635 (7Y98 / 7Y99)
|
SR655 (7Y00 / 7Z01)
|
SR850 (7X18/7X19)
|
SR860 (7X69/7X70)
|
SR950 (7X11/12/13)
|
SD530 (7X21)
|
SD650 (7X58)
|
SN550 (7X16)
|
SN850 (7X15)
|
|
M.2 adapters and modules | ||||||||||||||||||||||
M.2 Enablement Kit, 7Y37A01092 | Y | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y† | Y |
M.2 with Mirroring Enablement Kit, 7Y37A01093 | N | N | N | N | N | Y | Y | Y | Y | Y | Y | Y | Y | N | N | Y | Y | Y | Y | Y | Y | Y |
SE350 M.2 Mirroring Enablement Kit, 4M17A60519 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 SATA 2-Bay RAID Enablement Kit, 4Y37A09739 | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N |
M.2 SATA/NVMe 2-Bay Enablement Kit, 4Y37A09738 | N | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N |
SE350 M.2 SATA/NVMe 4-bay Data Drive Enablement Kit, 4M17A37281 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SE350 M.2 SATA 4-Bay Data RAID Mirroring Enablement Kit, 4M17A37606 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 thermal kit | ||||||||||||||||||||||
M.2 480GB SSD Thermal Kit, 4XH7A08791 | N | N | N | N | N | N | N | Y | N | Y | N | Y | N | N | N | N | N | N | N | N | N | N |
Lite-On SATA drives | ||||||||||||||||||||||
M.2 32GB SATA 6Gbps SSD, 7N47A00129 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | N | Y | Y | Y | Y | Y | Y | Y |
M.2 128GB SATA 6Gbps SSD, 7N47A00130 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Micron 5100 SATA drives (non-SED) | ||||||||||||||||||||||
M.2 5100 240GB SATA 6Gbps SSD, 4XB7A14049 | N | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | N | N | N | Y | Y | Y | Y | Y | Y | Y |
M.2 5100 480GB SATA 6Gbps SSD, 7SD7A05703 | Y | N | Y | Y | Y | Y | Y | Y‡ | Y | Y‡ | Y | Y‡ | N | Y | Y | Y | Y | Y | Y | N | Y | Y |
M.2 5100 960GB SATA 6Gbps SSD, 4XB7A14048 | Y | N | N | N | N | N | N | N | N | N | N | N | N | Y | Y | N | N | N | N | N | N | N |
M.2 1.92TB 5100 Pro SATA 6Gbps SSD, 4XB7A39425 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Micron 5100 SATA SED drives (TCG-e encryption) | ||||||||||||||||||||||
M.2 480GB 5100 Pro SATA 6Gbps SED SSD, 4XB7A37273 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 960GB 5100 Pro SATA 6Gbps SED SSD, 4XB7A37274 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 1.92TB 5100 Pro SATA 6Gbps SED SSD, 4XB7A37275 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
ATP A600i Industrial SATA drives (non-SED) | ||||||||||||||||||||||
M.2 120GB Industrial A600i SATA SSD, 4XB7A39422 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 480GB Industrial A600i SATA SSD, 4XB7A39423 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 800GB Industrial A600i SATA SSD, 4XB7A39424 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
ATP A600i Industrial SATA SED drives (Opal encryption) | ||||||||||||||||||||||
M.2 120GB Industrial A600i SATA SED SSD, 4XB7A37270 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 480GB Industrial A600i SATA SED SSD, 4XB7A37271 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 800GB Industrial A600i SATA SED SSD, 4XB7A37272 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Intel P4511 SATA drives (non-SED) | ||||||||||||||||||||||
M.2 650GB P4511 NVMe High Endurance SSD, 4XB7A37276 | Y* | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 1TB P4511 NVMe SSD, 4XB7A37277 | Y* | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 2TB P4511 NVMe SSD, 4XB7A37278 | Y* | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Intel P4511 SATA SED drives (Opal encryption) | ||||||||||||||||||||||
M.2 650GB P4511 NVMe SED High Endurance SSD, 4XB7A39426 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 1TB P4511 NVMe SED SSD, 4XB7A39427 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
M.2 2TB P4511 NVMe SED SSD, 4XB7A39428 | Y | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
* Planned for 4Q/2019
† Support of the M.2 Enablement Kit (7Y37A01092) in the SN550 is configure-to-order only. It cannot be installed in the SN550 as a field upgrade option.
‡ The use of the 480GB M.2 drive in the SR550, SR590 and SR650 may require that the M.2 480GB SSD Thermal Kit (4XH7A08791) also be installed. The thermal kit contains an air baffle that ensures proper cooling of the M.2 drive. See the SR550, SR590 and SR650 product guides for specifics.
Operating system support
The adapters support the following operating systems:
- ThinkSystem M.2 Enablement Kit, 7Y37A01092
- ThinkSystem M.2 with Mirroring Enablement Kit, 7Y37A01093
Tip: These tables are automatically generated based on data from Lenovo ServerProven.
Operating systems | SE350 |
SD530 (Gen 2) |
SD650 (Gen 2) |
SN550 (Gen 2) |
SN850 (Gen 2) |
SR530 (Gen 2) |
SR550 (Gen 2) |
SR570 (Gen 2) |
SR590 (Gen 2) |
SR630 (Gen 2) |
SR650 (Gen 2) |
SR670 (Gen 2) |
SR850 (Gen 2) |
SR860 (Gen 2) |
SR950 (Gen 2) |
ST550 (Gen 2) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For OS support info. please refer to LeSI Best Recipe. | N | N | Y 1 | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2012 R2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server version 1803 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.10 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.9 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.5 | N | N | N | N | N | N | N | N | N | N | N | Y | N | N | N | N |
Red Hat Enterprise Linux 7.6 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP4 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U1 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | N | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (Xeon SP Gen 2), M/T 7X58 (Xeon SP Gen 2). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This item shall be installed/removed by Lenovo support rep only.
Operating systems | SD530 (Gen 1) |
SD650 (Gen 1) |
SN850 (Gen 1) |
SR530 (Gen 1) |
SR550 (Gen 1) |
SR570 (Gen 1) |
SR590 (Gen 1) |
SR630 (Gen 1) |
SR650 (Gen 1) |
SR670 (Gen 1) |
SR850 (Gen 1) |
SR860 (Gen 1) |
SR950 (Gen 1) |
ST550 (Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For OS support info. please refer to LeSI Best Recipe. | N | Y 1 | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2012 R2 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server 2016 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server version 1803 | Y | N | N | N | N | N | N | Y | Y | N | Y | Y | Y | N |
Red Hat Enterprise Linux 6.10 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.9 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.3 | Y | N | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
Red Hat Enterprise Linux 7.4 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.5 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.6 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP2 | Y | N | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
SUSE Linux Enterprise Server 12 SP2 with Xen | Y | N | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
SUSE Linux Enterprise Server 12 SP3 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP3 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 | Y | N | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (M/T 7X58). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This Item shall be installed/removed by Lenovo support rep only.
Operating systems | SD530 (Gen 2) |
SD650 (Gen 2) |
SN550 (Gen 2) |
SN850 (Gen 2) |
SR530 (Gen 2) |
SR550 (Gen 2) |
SR570 (Gen 2) |
SR590 (Gen 2) |
SR630 (Gen 2) |
SR650 (Gen 2) |
SR670 (Gen 2) |
SR850 (Gen 2) |
SR860 (Gen 2) |
SR950 (Gen 2) |
ST550 (Gen 2) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For OS support info. please refer to LeSI Best Recipe. | N | Y 1 | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2012 R2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2016 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server version 1803 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.10 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 6.9 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
Red Hat Enterprise Linux 7.5 | N | N | N | N | N | N | N | N | N | N | Y | N | N | N | N |
Red Hat Enterprise Linux 7.6 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 11 SP4 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP2 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP3 with Xen | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
SUSE Linux Enterprise Server 12 SP4 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | N | N | N | N | N | N | N | N | N | N | N | N | N | N | N |
VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (Xeon SP Gen 2), M/T 7X58 (Xeon SP Gen 2). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This item shall be installed/removed by Lenovo support rep only.
Operating systems | SD530 (Gen 1) |
SD650 (Gen 1) |
SN550 (Gen 1) |
SN850 (Gen 1) |
SR530 (Gen 1) |
SR550 (Gen 1) |
SR570 (Gen 1) |
SR590 (Gen 1) |
SR630 (Gen 1) |
SR650 (Gen 1) |
SR670 (Gen 1) |
SR850 (Gen 1) |
SR860 (Gen 1) |
SR950 (Gen 1) |
ST550 (Gen 1) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For OS support info. please refer to LeSI Best Recipe. | N | Y 1 | N | N | N | N | N | N | N | N | N | N | N | N | N |
Microsoft Windows Server 2012 R2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server 2016 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server 2019 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server version 1709 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Microsoft Windows Server version 1803 | Y | N | Y | N | N | N | N | N | Y | Y | N | Y | Y | Y | N |
Red Hat Enterprise Linux 6.10 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 6.9 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.3 | Y | N | Y | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
Red Hat Enterprise Linux 7.4 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.5 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.6 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
Red Hat Enterprise Linux 7.7 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.0 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
Red Hat Enterprise Linux 8.1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 11 SP4 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP2 | Y | N | Y | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
SUSE Linux Enterprise Server 12 SP2 with Xen | Y | N | Y | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
SUSE Linux Enterprise Server 12 SP3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP3 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP4 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 12 SP5 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 SP1 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
SUSE Linux Enterprise Server 15 with Xen | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.0 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 | Y | N | Y | Y | Y | Y | N | N | Y | Y | N | Y | N | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.5 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U1 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U2 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
VMware vSphere Hypervisor (ESXi) 6.7 U3 | Y | N | Y | Y | Y | Y | Y | Y | Y | Y | N | Y | Y | Y | Y |
1 1. This item is not a general stand-alone option for Lenovo ThinkSystem SD650 (M/T 7X58). 2. For OS support matrix, pls refer to LeSI Best Recipe. 3. This Item shall be installed/removed by Lenovo support rep only.
Warranty
The M.2 drives and M.2 adapters carry a one-year, customer-replaceable unit (CRU) limited warranty. When the drives and adapters are installed in a supported server, these drives assume the server’s base warranty and any warranty upgrades.
Solid State Memory cells have an intrinsic, finite number of program/erase cycles that each cell can incur. As a result, each solid state device has a maximum amount of program/erase cycles to which it can be subjected. The warranty for Lenovo solid state drives (SSDs) is limited to drives that have not reached the maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the SSD product. A drive that reaches this limit may fail to operate.
Physical specifications
M.2 drives have the following dimensions and weight:
- 2242 form factor drives: 22 mm x 42 mm, 5 g
- 2280 form factor drives: 22 mm x 80 mm, 10 g
M.2 adapters have the following dimensions and weight:
- Single M.2 Adapter: 117 mm x 30 mm, 17 g
- Dual M.2 Adapter: 117 mm x 30 mm, 18 g
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
ServerProven®
ThinkSystem
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Linux® is a trademark of Linus Torvalds in the United States, other countries, or both.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.