Lenovo ThinkSystem SR850 ServerProduct Guide

Abstract

The Lenovo ThinkSystem SR850 is a 4-socket server that features a streamlined 2U rack design, optimized for price and performance, with best-in-class flexibility and expandability.

This product guide provides essential pre-sales information to understand the ThinkSystem SR850 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SR850 and consider its use in IT solutions.

Change History

Changes in the October 12 update:

Walkthrough Video with David Watts and Tisha Jefferson

Introduction

The Lenovo ThinkSystem SR850 is a 4-socket server that features a streamlined 2U rack design that is optimized for price and performance, with best-in-class flexibility and expandability. Models of the SR850 are powered by up to four Intel Xeon Processor Scalable Family processors, each with up to 28 cores, for an efficient 4-socket solution. The ThinkSystem SR850’s agile design provides rapid upgrades for processors and memory, and its large, flexible storage capacity helps to keep pace with data growth.

Suggested uses: General business consolidation, data analytics, virtualization, database, dense computing and scientific applications

Lenovo ThinkSystem SR850
Figure 1. Lenovo ThinkSystem SR850

Did you know?

With a dense 2U design, the Lenovo ThinkSystem SR850 provides advanced features and capabilities. These include support for up to four sockets and 48 DIMMs, mix and match internal storage, and enterprise-grade systems management with the embedded Lenovo XClarity Controller.

The SR850 has space for 16x 2.5-inch drive bays, up to 8 of which can be configured as AnyBay drives - supporting SAS, SATA or NVMe drives. NVMe drives are high-speed, low-latency storage, ideal for storage tiering. The server also offers easy expansion, with up to nine PCIe slots (two of which are x16) and up to 2 (mirrored) M.2 drives for rapid OS boot, faster than either USB keys or SD cards.

Key features

The flexible ThinkSystem SR850 server can scale from two to four Intel Xeon Gold or Platinum processors, delivering significantly faster performance than the previous generation. Built for standard workloads like general business applications and server consolidation, it can also accommodate high-growth areas such as databases and virtualization. The ThinkSystem SR850’s agile design permits rapid upgrades for processors and memory, and its large, flexible storage capacity helps to keep pace with data growth.

With the capability to support up to 48 DIMMs, four sockets, mix-and-match internal storage with up to 16 drives, and a dedicated slot for Gigabit or 10 GbE networking, the SR850 provides unmatched features and capabilities in a dense 2U rack-mount design.

Scalability and performance

The SR850 offers numerous features to boost performance, improve scalability and reduce costs: 

  • Supports Gold and Platinum level processors in the Intel Xeon Processor Scalable Family. Processors supported have up to 28 cores, core speeds of up to 3.6GHz, L3 cache sizes up to 38.5 MB, and TDP ratings of up to 165W.
  • The SR850's processor mezzanine tray design enables you to start with two processors and 24 DIMM sockets and upgrade to four processors and 48 DIMM sockets when you need it, helping lower initial costs and manage growth.
  • Up to four processors, 48 cores, and 96 threads maximize the concurrent execution of multithreaded applications.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily going beyond processor TDP.
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Support for up to 48 TruDDR4 memory DIMMs operating at 2666 MHz means you have the fastest available memory subsystem and memory capacity of up to 3.0 TB using 48x 64 GB LRDIMMs.
  • Future processor options are planned to support 128 GB 3DS RDIMMs which will enable the SR850 to support 6.0 TB of high-speed TruDDR4 memory (M-suffix processor support and 3DS RDIMM support is planned for a future date)
  • The use of solid-state drives (SSDs) instead of, or along with, traditional spinning drives (HDDs), can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • Up to 16x 2.5-inch drives -- SAS or SATA HDDs, SAS or SATA SSDs and the new NVMe PCIe SSDs -- provide a flexible and scalable all-in-one platform to meet your increasing demands.
  • Support for up to 8 NVMe PCIe SSDs in a 2.5-inch form factor maximizes drive I/O performance, in terms of throughput, bandwidth, and latency.
  • New high-speed RAID controllers from Broadcom provide 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache up to 4 GB and support for 16 drives on a single controller.
  • Supports a new Lenovo patented-design M.2 adapter for convenient operating system boot functions. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for boot drive performance and reliability.
  • The server has a dedicated flexible LAN-on-motherboard (LOM) slot, supporting a variety of 10 GbE or Gigabit Ethernet adapters that do not occupy one of the standard PCIe slots.
  • A total of up to 11 PCIe slots: 9 general-purpose PCIe 3.0 slots plus slots dedicated to the LOM adapter and the M.2 adapter.
  • The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).

Availability and serviceability

The SR850 provides many features to simplify serviceability and increase system uptime:

  • The server offers Single Device Data Correction (SDDC, also known as Chipkill), Adaptive Double- Device Data Correction (ADDDC, also known as Redundant Bit Steering or RBS), memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • The server offers hot-swap drives, supporting RAID redundancy for data protection and greater system uptime.
  • The Dual M.2 Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
  • The server has up to two hot-swap redundant power supplies and six hot-swap redundant fans to provide availability for business-critical applications.
  • The power-source-independent light path diagnostics uses LEDs to lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps improve system availability.
  • The optional LCD system information display panel provides more detailed diagnostics by displaying all error messages and VPD data needed for a service call, thereby aiding with problem resolution and system uptime.
  • Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, flash storage adapters), fans, power supplies, RAID controllers, server ambient and subcomponent temperatures. Alerts can be surfaced through the XClarity Controller to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • Solid-state drives (SSDs) offer more reliability than traditional mechanical HDDs for greater uptime.
  • The built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager collects and saves service data to USB key drive or remote CIFS share folder, for troubleshooting and to reduce service time.
  • Auto restart in the event of a momentary loss of AC power (based on the power policy setting in the XClarity Controller service processor)
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
  • Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

Powerful systems management features simplify local and remote management of the SR850:

  • Lenovo XClarity Controller (XCC) monitors server availability and performs remote management. XCC Advanced is standard, which enables remote KVM. Optional XCC Enterprise enables the mounting of remote media files (ISO and IMG image files), boot capture, and power capping.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager, which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic methods, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure only a digitally signed operating system can be used. Supported with HDDs and SSDs, as well as M.2 drives in the M.2 Adapter.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.

Energy efficiency

The SR850 offers the following energy-efficiency features to save energy, reduce operational costs, and increase energy availability:

  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum certifications
  • Intel Intelligent Power Capability turns individual processor elements on and off as needed to reduce power draw.
  • Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
  • Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system and thus keeping your system cooler.
  • Optional Lenovo XClarity Energy Manager provides advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.

Components and connectors

The following figure shows the front of the server.

Front view of the Lenovo ThinkSystem SR850
Figure 2. Front view of the Lenovo ThinkSystem SR850

The following figure shows the rear of the server.


Figure 3. Rear view of the Lenovo ThinkSystem SR850

The following figure shows the locations of key components inside the server.

Inside view of the Lenovo ThinkSystem SR850
Figure 4. Internal view of the Lenovo ThinkSystem SR850

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications
Components Specification
Machine types 7X18 - 1 year warranty
7X19 - 3 year warranty
Form factor 2U rack.
Processor Up to four Intel Xeon Processor Scalable Family of processors, either Gold or Platinum level processors (formerly codename "Skylake"). Supports processors up to 28 cores, core speeds up to 3.6 GHz, and TDP ratings up to 165W. Two processor sockets on the system board and two processors on the Processor and Memory Expansion Tray (standard on most models). Two Intel Ultra Path Interconnect (UPI) links at 10.4 GT/s each. Four processors are connected in a ring topology.
Chipset Intel C624 "Lewisburg" chipset
Memory Up to 48 DIMM sockets (12 DIMMs per processor) supporting Lenovo TruDDR4 DIMMs at up to 2666 MHz. RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be mixed. There are 24 DIMM sockets on the system board, and an additional 24 DIMM sockets on the processor and memory expansion tray (standard on most models).
Memory maximums With RDIMMs: Up to 1.5 TB with 48x 32 GB RDIMMs and four processors.
With LRDIMMs: Up to 3.0 TB with 48x 64 GB LRDIMMs and four processors.
Planned support for up to 6.0 TB with 48x 128 GB 3DS RDIMMs (requires M-suffix processors that support greater than 786 GB memory per processor)
Memory protection ECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory sparing.
Disk drive bays Up to 16 2.5-inch hot-swap SAS/SATA bays.
Maximum internal storage Up to 245.76 TB with 16x 15.36 TB 2.5" SAS SSDs, or up to 32 TB with 16x 2.0 TB 2.5” 7.2K SAS HDDs. With 8x SAS/SATA and 8x NVMe drives, up to 153.6 TB with 8x 15.36 TB 2.5" SAS SSDs and 8x 3.84 TB U.2 2.5" NVMe SSDs. Mix of SSDs/HDDs supported.
Storage controller
  • No embedded RAID
  • 12 Gb SAS/SATA RAID adapters:
    • RAID 530i (cacheless) supports RAID 0, 1, 10, 5, 50
    • RAID 730-8i (China only) with 1GB cache supports RAID 0, 1, 10, 5, 50
    • RAID 930-8i with 2GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
    • RAID 930-16i and 24i with 4GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
  • 12 Gb SAS/SATA non-RAID: 430-8i and 430-16i HBAs
Optical drive bays No internal optical drive.
Tape drive bays No internal backup drive.
Network interfaces Integrated 10Gb Ethernet controller, based on the Intel Ethernet Connection X722. The server supports 1 of 6 available Phy adapters, providing either 2- or 4-port Gigabit Ethernet, 2- or 4-port 10 GbE with SFP+ connections or 2- or 4-port 10 GbE with RJ45 connections. One port can optionally be shared with the XClarity Controller (XCC) management processor for Wake-on-LAN and NC-SI support.
PCI Expansion slots

Up to 11 PCIe slots including a slot reserved for the M.2 adapter. Eight slots are on the system board and three (slots 3-5) are through a riser card. Three riser cards are available. All 11 slots are available with two processors.

 The slots are as follows:

  • Slot 1: PCIe 3.0 x16 (low profile)
  • Slot 2: PCIe 3.0 x8 (low profile)
  • Slot 3-5: Riser card slots (choices are x8/x8/x8, x8/x8/x8ML2 and x8/x16ML2)
  • Slot 6: PCIe 2.0 x2 / 6 Gb SATA slot reserved to M.2 adapter and drives
  • Slot 7: Reserved for Ethernet LOM phy adapter
  • Slot 8: PCIe 3.0 x8 (low profile)
  • Slot 9: PCIe 3.0 x8 (low profile)
  • Slot 10: PCIe 3.0 x8 (low profile)
  • Slot 11: PCIe 3.0 x16 (low profile)
Ports

Front: Two USB 2.0 ports or one USB 2.0 and one USB 3.0 port, model dependent. The first USB 2.0 port can be configured to support local systems management by using the XClarity Administrator mobile app on a mobile device connected via a USB cable. Optional front VGA video port (CTO or field upgrade). 

Rear: Two USB 3.0 ports, one VGA video port, one DB-9 serial port, and one RJ-45 XClarity Controller (XCC) systems management port. The serial port can be shared with the XCC for serial redirection functions.

Internal: Optional M.2 adapter in dedicated slot supporting one or two M.2 drives (for OS boot support, including hypervisor support).

Cooling Six N+1 redundant hot swap 60 mm fans (all six standard). One fan integrated in each power supply.
Power supply Up to two hot-swap redundant AC power supplies (all 80 PLUS Platinum certification): 750 W, 1100 W and 1600 W AC options, supporting 220 V AC. 750 W and 1100 W options also support 110V input supply. In China only, all power supply options support 240 V DC. Second power supply requires either Processor and Memory Expansion Tray or a power interposer card.
Video G200 graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Hot-swap parts Drives, power supplies, and fans.
Systems management XClarity Controller embedded management, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. XClarity Controller Advanced standard with the SR850; XClarity Controller Enterprise optional with software license upgrade. Light path diagnostics for local failure detection and reporting, with optional LCD diagnostics pull-out panel.
Security features Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 1.2 or TPM 2.0. In China only, optional Trusted Cryptographic Module (TCM). Lockable top cover. Optional lockable front security bezel.
Operating systems supported Microsoft Windows Server 2012 R2, 2016; RHEL 6 & 7 x64; SLES 11 & 12 x64; VMware ESXi 6.0, 6.5
Limited warranty Three-year or one-year (model dependent) customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Dimensions Height: 86 mm (3.4 in.), width: 445 mm (17.5 in.), depth: 776 mm (30.5 in.)
Weight Minimum configuration: 18 kg (40 lb.), maximum: 27 kg (59.6 lb)

The SR850 servers are shipped with the following items:

  • ThinkSystem Toolless Slide Rail
  • Documentation flyer
  • Power cords (model and region dependent)

Models

The following tables list the available models, grouped by region.

Models for Australia and New Zealand

All models have the following common features:

  • XCC Advanced with an available upgrade to XCC Enterprise
  • No power cords included; ensure desired power cords are added to the order
  • Slide Rail Kit (cable management arm is available but not included)
Table 2. Models for Australia and New Zealand
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
Front
USB
3.0
LCD
panel
Front
VGA
7X19 A003AU 2x Gold 5115 10C 85W 2.4GHz 2x 8GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No No Option
7X19 A009AU 2x Gold 5115 10C 85W 2.4GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No No Option
7X19 A025AU 2x Gold 5118 12C 105W 2.3GHz 2x 16GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No No Option
7X19 A029AU 2x Gold 5118 12C 105W 2.3GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No No Option
7X19 A01GAU 2x Gold 5120 14C 105W 2.2GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS Yes Yes Option
7X19 A00DAU 2x Gold 6134 8C 130W 3.2GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A010AU 2x Gold 6136 12C 150W 3.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A01VAU 2x Gold 6138 20C 125W 2.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A01MAU 2x Gold 6140 18C 140W 2.3GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A00NAU 2x Gold 6142 16C 150W 2.6GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A02CAU 2x Gold 6152 22C 140W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A01AAU 2x Platinum 8153 16C 125W 2.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A01DAU 2x Platinum 8160 24C 150W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A01ZAU 2x Platinum 8164 26C 150W 2.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Yes Option
7X19 A00PAU 2x Platinum 8170 26C 165W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1600W HS Yes Yes Option
7X19 A00MAU 2x Platinum 8176 28C 165W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1600W HS Yes Yes Option

† Processor detail: Quantity, model, core count, TDP, core frequency

Models for South East Asian countries (ASEAN)

All models have the following common features:

  • XCC Advanced with an available upgrade to XCC Enterprise
  • VGA port on the front of the server
  • Pull-out LCD Display Panel
  • USB 3.0 port on the front of the server
  • No power cords included; ensure desired power cords are added to the order
  • Slide Rail Kit (cable management arm is available but not included)
Table 3. Models for South East Asian countries (ASEAN)
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
7X19 A00GSG 2x Gold 5115 10C 85W 2.4GHz 2x 16GB 2Rx8 RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS
7X19 A00QSG 2x Gold 5118 12C 105W 2.3GHz 2x 16GB 2Rx8 RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS
7X19 A012SG 2x Gold 5120 14C 105W 2.2GHz 2x 16GB 2Rx8 RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS
7X19 A02BSG 2x Gold 6126 12C 125W 2.6GHz 2x 16GB 2Rx8 RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS
7X19 A00XSG 2x Gold 6130 16C 125W 2.1GHz 2x 32GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS
7X19 A017SG 2x Gold 6134 8C 130W 3.2GHz 2x 16GB 2Rx8 RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS
7X19 A00VSG 2x Gold 6140 18C 140W 2.3GHz 2x 32GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1600W HS
7X19 A01JSG 2x Gold 6148 20C 150W 2.4GHz 2x 32GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1600W HS
7X19 A01BSG 2x Gold 6152 22C 140W 2.1GHz 2x 32GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency

Models for EMEA countries

All models have the following common features:

  • XCC Advanced with an available upgrade to XCC Enterprise
  • Pull-out LCD Display Panel
  • No power cords included; ensure desired power cords are added to the order
  • Slide Rail Kit (cable management arm is available but not included)
Table 4. Models for EMEA countries
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
Front
USB
3.0
Front
VGA
7X19 A02GEA 4x Gold 5115 10C 85W 2.4GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS Yes Yes
7X19 A02HEA 4x Gold 5118 12C 105W 2.3GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS Yes Yes
7X19 A02JEA 4x Gold 5120 14C 105W 2.2GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS Yes Yes
7X19 A02KEA 4x Gold 6126 12C 125W 2.6GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS Yes Yes
7X19 A02LEA 4x Gold 6130 16C 125W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS Yes Yes
7X19 A02MEA 4x Gold 6138 20C 125W 2.0GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS Yes Yes
7X19 A02NEA 4x Gold 6148 20C 150W 2.4GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes
7X19 A02PEA 4x Gold 6150 18C 165W 2.7GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes
7X19 A02QEA 4x Gold 6152 22C 140W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes
7X19 A02REA 4x Platinum 8160 24C 150W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes
7X19 A02SEA 4x Platinum 8164 26C 150W 2.0GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes
7X19 A02TEA 4x Platinum 8170 26C 165W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes
7X19 A02UEA 4x Platinum 8176 28C 165W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS Yes Yes

† Processor detail: Quantity, model, core count, TDP, core frequency

Models for Hong Kong, Taiwan, Korea (HTK)

All models have the following common features:

  • XCC Advanced with an available upgrade to XCC Enterprise
  • No VGA port on the front of the server; available as an option
  • Basic operator panel (no pull-out LCD Display Panel)
  • No power cords included; ensure desired power cords are added to the order
  • Slide Rail Kit (cable management arm is available but not included)
Table 5. Models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
Front
USB
3.0
7X19 A021CN 2x Gold 5115 10C 85W 2.4GHz 2x 16GB 2Rx8 2x RAID 930-8i 16x 2.5" / 16 Open 4x1Gb 8 / 11 1x 750W HS No
7X19 A01TCN 2x Gold 5118 12C 105W 2.3GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A01RCN 2x Gold 5120 14C 105W 2.2GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A01PCN 2x Gold 5122 4C 105W 3.6GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A022CN 2x Gold 6126 12C 125W 2.6GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A01WCN 2x Gold 6130 16C 125W 2.1GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A02DCN 2x Gold 6134 8C 130W 3.2GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A02ACN 2x Gold 6136 12C 150W 3.0GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A00RCN 2x Gold 6140 18C 140W 2.3GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A00ZCN 2x Gold 6142 16C 150W 2.6GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A011CN 2x Gold 6150 18C 165W 2.7GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A00BCN 2x Gold 6152 22C 140W 2.1GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A007CN 2x Platinum 8153 16C 125W 2.0GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A024CN 2x Platinum 8156 4C 105W 3.6GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A026CN 2x Platinum 8158 12C 150W 3.0GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A004CN 2x Platinum 8160 24C 150W 2.1GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A00CCN 2x Platinum 8164 26C 150W 2.0GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A00FCN 2x Platinum 8170 26C 165W 2.1GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A00ECN 2x Platinum 8176 28C 165W 2.1GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes
7X19 A027CN 2x Gold 5120T 14C 105W 2.2GHz 2x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 Open 4x1Gb 11 / 11 1x 750W HS Yes

† Processor detail: Quantity, model, core count, TDP, core frequency

Models for India

All models have the following common features:

  • XCC Advanced with an available upgrade to XCC Enterprise
  • No VGA port on the front of the server; available as an option
  • Basic operator panel (no pull-out LCD Display Panel)
  • Power cords included: 2.8m, 10A/250V, C13 to IS 6538, except for 7X19A005SG which includes 2.8m,10A/230V,C13 to CEE7-VII instead
Table 6. Models for India
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
Front
USB
3.0
Rail
kit
7X19 A023SG 2x Gold 5115 10C 85W 2.4GHz 2x 8GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No Slide Rail
7X19 A013SG 2x Gold 5115 10C 85W 2.4GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No Slide Rail
7X19 A005SG 2x Gold 5118 12C 105W 2.3GHz 2x 16GB 2Rx8 RAID 530-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS Yes Friction Rail
7X19 A01ESG 2x Gold 5118 12C 105W 2.3GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No Slide Rail
7X19 A016SG 2x Gold 5118 12C 105W 2.3GHz 2x 16GB RAID 530-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS No Slide Rail
7X19 A020SG 2x Gold 5120 14C 105W 2.2GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS Yes Option
7X19 A01KSG 2x Gold 5120 14C 105W 2.2GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 750W HS Yes Slide Rail
7X19 A01QSG 2x Gold 6134 8C 130W 3.2GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A01NSG 2x Gold 6136 12C 150W 3.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A028SG 2x Gold 6138 20C 125W 2.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A01HSG 2x Gold 6140 18C 140W 2.3GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A01FSG 2x Gold 6142 16C 150W 2.6GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A00ASG 2x Gold 6152 22C 140W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A006SG 2x Platinum 8153 16C 125W 2.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A002SG 2x Platinum 8160 24C 150W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A00LSG 2x Platinum 8164 26C 150W 2.0GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1100W HS Yes Slide Rail
7X19 A00KSG 2x Platinum 8170 26C 165W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1600W HS Yes Slide Rail
7X19 A00HSG 2x Platinum 8176 28C 165W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x1Gb 8 / 11 1x 1600W HS Yes Slide Rail

† Processor detail: Quantity, model, core count, TDP, core frequency

Models for Japan

All models have the following common features:

  • VGA port on the front of the server
  • Pull-out LCD Display Panel
  • No power cords included; ensure desired power cords are added to the order
  • Slide Rail Kit (cable management arm is available but not included)
Table 7. Models for Japan
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
Front
USB
3.0
XCC
Upgrade
7X19 A01UJP 2x Gold 5115 10C 85W 2.4GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x10Gb RJ45 11 / 11 1x 1100W HS No Option
7X19 A02FJP 2x Gold 6150 18C 165W 2.7GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x10Gb SFP+ 8 / 11 1x 1600W HS Yes Yes
7X19 A02EJP 2x Platinum 8176 28C 165W 2.1GHz 2x 16GB RAID 930-8i 8x 2.5" SAS / 16 Open 4x10Gb SFP+ 8 / 11 1x 1600W HS Yes Yes

† Processor detail: Quantity, model, core count, TDP, core frequency

Models for Latin American countries (except Brazil)

All models have the following common features:

  • VGA port on the front of the server
  • Pull-out LCD Display Panel
  • USB 3.0 port on the front of the server
  • No power cords included; ensure desired power cords are added to the order
Table 8. Models for Latin American countries (except Brazil)
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
XCC
Upgrade
Rail
kit
7X19 A037LA 2x Gold 6140 18C 140W 2.3GHz 12x 16GB 2Rx8 RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1100W HS Yes Slide Rail
7X19 A033LA 2x Gold 6148 20C 150W 2.4GHz 12x 16GB 2Rx8 RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1100W HS Yes Slide Rail
7X19 A032LA 2x Platinum 8153 16C 125W 2.0GHz 12x 32GB RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1100W HS Yes Slide Rail
7X19 A03ELA 2x Platinum 8160 24C 150W 2.1GHz 12x 32GB RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1100W HS Yes Slide Rail
7X19 A03CLA 2x Platinum 8164 26C 150W 2.0GHz 12x 32GB RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1600W HS Yes Slide Rail
7X19 A03BLA 2x Platinum 8170 26C 165W 2.1GHz 12x 32GB RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1600W HS Yes Slide Rail
7X19 A03FLA* 4x Platinum 8170 26C 165W 2.1GHz 16x 32GB RAID 930-16i 16x 2.5" / 16 (4x AnyBay) Open 4x1Gb 11 / 11 2x 1600W HS Option Slide Rail + CMA
7X19 A03HLA* 4x Platinum 8170 26C 165W 2.1GHz 32x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 (4x AnyBay) Open 4x1Gb 11 / 11 2x 1600W HS Option Slide Rail + CMA
7X19 A03ALA 2x Platinum 8176 28C 165W 2.1GHz 12x 32GB RAID 930-8i 8x 2.5" SAS / 16 Open Open 11 / 11 2x 1600W HS Yes Slide Rail
7X19 A03GLA* 4x Platinum 8176 28C 165W 2.1GHz 16x 32GB RAID 930-16i 16x 2.5" / 16 (4x AnyBay) Open 4x1Gb 11 / 11 2x 1600W HS Option Slide Rail + CMA
7X19 A03JLA* 4x Platinum 8176 28C 165W 2.1GHz 32x 16GB 2Rx8 RAID 930-16i 16x 2.5" / 16 (4x AnyBay) Open 4x1Gb 11 / 11 2x 1600W HS Option Slide Rail + CMA

† Processor detail: Quantity, model, core count, TDP, core frequency

* Also includes one external USB DVD-RW drive

Models for USA and Canada

All models have the following common features:

  • XCC Advanced with an available upgrade to XCC Enterprise
  • VGA port on the front of the server
  • Pull-out LCD Display Panel
  • Front USB ports are USB 2.0
  • No power cords included; ensure desired power cords are added to the order
  • Slide Rail Kit (cable management arm is available but not included)
Table 9. Models for USA and Canada
Model Intel Xeon
processors†
Memory RAID Drive bays Drives Ethernet
LOM
Slots Power
supplies
7X19 A008NA 4x Gold 5115 10C 85W 2.4GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS
7X19 A018NA 4x Gold 5118 12C 105W 2.3GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS
7X19 A019NA 4x Gold 5120 14C 105W 2.2GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS
7X19 A01CNA 4x Gold 6126 12C 125W 2.6GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS
7X19 A00SNA 4x Gold 6130 16C 125W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS
7X19 A00UNA 4x Gold 6138 20C 125W 2.0GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1100W HS
7X19 A00YNA 4x Gold 6148 20C 150W 2.4GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS
7X19 A014NA 4x Gold 6150 18C 165W 2.7GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS
7X19 A015NA 4x Gold 6152 22C 140W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS
7X19 A01LNA 4x Platinum 8160 24C 150W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS
7X19 A01YNA 4x Platinum 8164 26C 150W 2.0GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS
7X19 A00JNA 4x Platinum 8170 26C 165W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS
7X19 A00TNA 4x Platinum 8176 28C 165W 2.1GHz 4x 32GB RAID 930-8i 8x 2.5" / 16 (4x AnyBay) Open Open 11 / 11 2x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency

Processor options

The SR850 supports Gold and Platinum level processors in the Intel Xeon Processor Scalable Family.

The server supports two or four processors.

  • Processors 1 and 2 are installed in sockets on the system board.
  • Processors 3 and 4 are installed on the Processor and Memory Expansion Tray.

The SR850 Processor and Memory Expansion Tray has a patent-pending sliding and rolling lift mechanism that requires only a one-handed operation to insert or remove from the server. It has a toolless design for superior usability, serviceability and reliability. 

SR850 Processor and Memory Expansion Tray
Figure 5. SR850 Processor and Memory Expansion Tray

The ordering information for the Processor and Memory Expansion Tray is shown in the following table.

Table 10. Processor and Memory Expansion Tray
Part number Feature code Description
7B27A03953 AUPY SR850 Processor and Memory Expansion Tray

The following processor quantities are supported:

  • Two processors, installed in sockets 1 and 2, without the Processor and Memory Expansion Tray
  • Four processors, installed in all four sockets

Note: Configurations of one or three processors are not supported.

The SR850 supports the Intel Xeon Processor Scalable Family options listed in the following table.

All supported processors have the following characteristics:

  • 14 nm process technology
  • Six DDR4 memory channels
  • 48 PCIe 3.0 I/O lanes
  • 1 MB L2 cache
  • 1.375 MB L3 cache per core (except where larger, as noted with ** in the table below)
  • Intel Hyper-Threading Technology
  • Intel Turbo Boost Technology 2.0
  • Intel Advanced Vector Extensions 512 (AVX-512)
  • Intel Ultra Path Interconnect (UPI) links at 10.4 GT/s (replaces QPI)

With two processors installed, the two processors are connected together using one UPI link. With four processors installed, the processors are connected together using a ring topology, using two UPI links, one to each adjacent processor in the ring.

Processors with the T suffix have more robust thermal characteristics (higher T-case).

Table 11. Processor options
Part
number
Feature
code
Description Memory
speed
Supports
>768 GB
per CPU
L3 cache AVX-512
FMA units
7XG7A04974 AX8M Intel Xeon Gold 5115 10C 85W 2.4GHz 2400 MHz No 13.75 MB 1
7XG7A04971 AX7D Intel Xeon Gold 5118 12C 105W 2.3GHz 2400 MHz No 16.5 MB 1
7XG7A04970 AX7C Intel Xeon Gold 5120 14C 105W 2.2GHz 2400 MHz No 19.25 MB 1
7XG7A04972 AX7E Intel Xeon Gold 5120T 14C 105W 2.2GHz 2400 MHz No 19.25 MB 1
7XG7A04959 AX70 Intel Xeon Gold 5122 4C 105W 3.6GHz 2666 MHz* No 16.5 MB** 2*
7XG7A03949 AWEX Intel Xeon Gold 6126 12C 125W 2.6GHz 2666 MHz No 19.25 MB** 2
7XG7A03945 AX6D Intel Xeon Gold 6130 16C 125W 2.1GHz 2666 MHz No 22 MB 2
7XG7A04961 AX72 Intel Xeon Gold 6130T 16C 125W 2.1GHz 2666 MHz No 22 MB 2
7XG7A04957 AX6Y Intel Xeon Gold 6134 8C 130W 3.2GHz 2666 MHz No 24.75 MB** 2
7XG7A03948 AX6W Intel Xeon Gold 6136 12C 150W 3.0GHz 2666 MHz No 24.75 MB** 2
7XG7A03943 AX6Q Intel Xeon Gold 6138 20C 125W 2.0GHz 2666 MHz No 27.5 MB 2
7XG7A03944 AX6R Intel Xeon Gold 6140 18C 140W 2.3GHz 2666 MHz No 24.75 MB 2
7XG7A03946 AX6E Intel Xeon Gold 6142 16C 150W 2.6GHz 2666 MHz No 22 MB 2
7XG7A03942 AWEW Intel Xeon Gold 6148 20C 150W 2.4GHz 2666 MHz No 27.5 MB 2
7XG7A06760 AX6T Intel Xeon Gold 6150 18C 165W 2.7GHz 2666 MHz No 24.75 MB 2
7XG7A03941 AX6P Intel Xeon Gold 6152 22C 140W 2.1GHz 2666 MHz No 30.25 MB 2
7XG7A03938 AX6L Intel Xeon Platinum 8153 16C 125W 2.0GHz 2666 MHz No 22 MB 2
7XG7A03939 AWEV Intel Xeon Platinum 8156 4C 105W 3.6GHz 2666 MHz No 16.5 MB** 2
7XG7A04969 AX7B Intel Xeon Platinum 8158 12C 150W 3.0GHz 2666 MHz No 24.75 MB** 2
7XG7A03937 AWGJ Intel Xeon Platinum 8160 24C 150W 2.1GHz 2666 MHz No 33 MB 2
7XG7A03936 AX6K Intel Xeon Platinum 8164 26C 150W 2.0GHz 2666 MHz No 35.75 MB 2
7XG7A03935 AX6J Intel Xeon Platinum 8170 26C 165W 2.1GHz 2666 MHz No 35.75 MB 2
7XG7A03934 AX6H Intel Xeon Platinum 8176 28C 165W 2.1GHz 2666 MHz No 38.5 MB 2

* All Gold 5000-level processors, except the 5122, support 2400 MHz memory speeds and have one AVX-512 512-bit FMA units. The 5122 processor supports 2666 MHz and has two FMA units
** L3 cache is 1.375 MB per core except for processor indicated with ** where the cache size is larger

Memory options

The SR850 server supports TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict tolerances is selected. It is compatibility tested and tuned to maximize performance and reliability.

TruDDR4 memory has a unique signature programmed into the DIMM, which enables ThinkSystem servers to verify whether the memory installed is qualified and supported. From a service and support standpoint, TruDDR4 memory automatically assumes the system's warranty, and service and support provided worldwide.

The SR850 supports up to 12 DIMMs per processor, for a total of 48 DIMMs when four processors are installed. Each processor has six memory channels, and supports one or two DIMMs per channel.

All DIMMs can operate at a speed of 2666 MHz, both at 1 DIMM per channel and 2 DIMMs per channel. However, if the processor selected has a lower memory bus speed (eg 2400 MHz), then all DIMMs will operate at that lower speed.

The following table lists the memory options that are available for the SR850 server.

Table 12. Memory options
Part
number
Feature
code
Description Maximum
supported
RDIMMs
7X77A01301 AUU1 ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM 48 (12 per processor)
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 48 (12 per processor)
7X77A01303 AUNC ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM 48 (12 per processor)
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 48 (12 per processor)
LRDIMMs
7X77A01305 AUNE ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM 48 (12 per processor)

The following rules apply when selecting the memory configuration:

  • The server supports RDIMMs and LRDIMMs. Once available from Lenovo, 3DS RDIMMs will also be supported. UDIMMs are not supported.
  • Mixing RDIMMs and LRDIMMs is not supported.
  • Mixing 3DS RDIMMs with either RDIMMs or LRDIMMs is not supported.
  • Mixing x4 and x8 DIMMs is supported.
  • For best performance, populate memory DIMMs in quantities of 6 or 12 per processor, so that all memory channels are used.

The following memory protection technologies are supported:

  • ECC
  • Chipkill (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • Memory channel mirroring
  • Memory rank sparing

If memory channel mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per processor), and both DIMMs in a pair must be identical in type and size. 50% of the installed capacity is available to the operating system.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The largest rank in the channel will be automatically selected as the spare rank. The amount of memory available to the operating system depends on the number, capacity and rank counts of the DIMMs installed.

Internal storage

The server can support up to 16x 2.5-inch drives, SAS, SATA or NVMe, depending on the selected backplane configuration. You can mix drives in the same server, but not in the same array. Drives are all installed from the front of the server. The server also supports one or two M.2 drives, installed in an M.2 adapter.

In this section:

Backplanes and drive bays

The SR850 supports various internal storage configurations based on two different backplanes:

  • 8-drive SAS/SATA backplane for 8x 2.5-inch SAS or SATA drives
  • 8-drive SAS/SATA+AnyBay backplane for either:
    • 8x 2.5-inch SAS or SATA drives
    • 4x 2.5-inch SAS or SATA drives + 4x 2.5-inch U.2 (NVMe) drives

For configure-to-order (CTO) configurations, ordering information for the backplanes is in the following table.

Table 13. Backplane ordering
Part number Feature code Description
None* AUR5 ThinkSystem 2U 2.5" AnyBay 8-Bay Backplane Kit
None* AURA ThinkSystem 2U/Tower 2.5" SATA/SAS 8-Bay Backplane Kit

* Backplanes are configure-to-order (CTO) only; however, upgrade kits are available that include backplanes, as described in the Field upgrades section below.

Regular 2.5-inch SAS/SATA drive bays support only SAS or SATA drives, however the Lenovo AnyBay drive bay design allows a choice of SATA, SAS or NVMe drives. This design enables the flexibility to configure some of the bays with high-performance PCIe SSDs and still use the remaining bays for high-capacity HDDs, which is the ideal solution for storage tiering.

Backplane connections are as follows:

  • The 8-drive SAS/SATA backplane has two SAS/SATA connectors and connects to a supported RAID controller or SAS HBA.
  • The 8-drive SAS/SATA+AnyBay backplane has two SAS/SATA connectors and connects to a supported RAID controller or SAS HBA plus four PCIe connectors to connect to either two PCIe connectors on the Processor and Memory Expansion Tray (see Figure 4), or four PCIe connectors on a NVMe Switch adapter installed in a PCIe slot.

Five drive configurations are possible with these two backplanes:

  1. 8 drive bays, all SAS/SATA
  2. 8 drive bays, where 4 are AnyBay
  3. 16 drive bays, all SAS/SATA
  4. 16 drive bays, where 4 are AnyBay
  5. 16 drive bays, where 8 are AnyBay

These configurations are shown in the following figure.

Drive bay configurations
Figure 6. Drive bay configurations

Adapters and cabling

This section describes the adapter and cabling requirements for each of the five configurations. There are two aspects of the server configuration that determine what adapters are needed:

  • For configurations with two SAS/SATA backplanes, you can select either one 16-port SAS/SATA adapter or two 8-port SAS/SATA adapters
  • For AnyBay drive bays, cabling varies depending on whether the server has four processors and the Processor and Memory Expansion Tray (with its two NVMe connectors) installed. If the server has only two processors configured, then the NVMe ports are provided by a NVMe Switch adapter.

The five drive bay configurations are shown in the the subsections below. Where there are different adapter and cabling options, or for 2 or 4 processors, they are shown by the letters A, B, C, D. These configuration numbers are also later references in the Field upgrades section.

  1. 8x drive bays, all SAS/SATA
  2. 8x drive bays, where 4 are AnyBay
  3. 16x drive bays, all SAS/SATA
  4. 16x drive bays, where 4 are AnyBay
  5. 16x drive bays, where 8 are AnyBay

Tip: The adapters are described in detail in the Controllers for internal storage section.

1. 8 drive bays, all SAS/SATA

In this drive bay configuration, all eight drives are connected to one 8-port SAS/SATA RAID adapter or HBA using two backplane cables, as shown in the following figure.

Adapter and cabling for 8x drive bays, all SAS/SATA
Figure 7. Adapter and cabling for 8x drive bays, all SAS/SATA

2. 8 drive bays, where 4 are AnyBay

In 8-drive bay configurations where four of those drive bays are AnyBay drive bays, possible adapter and cabling configurations are shown in the following figure.

When only two processors are selected, a NVMe Switch Adapter is used to provide the four needed NVMe ports. When four processors are selected, the NVMe ports on the Processor and Memory Expansion Tray are used to connect to the NVMe connectors on the backplane.

In this configuration you can have up to eight SAS or SATA drives, or you can instead put up to four NVMe drives in the AnyBay drive bays, along with up to four SAS/SATA drives in the other drive bays.

Adapter and cabling for 8x drive bays, where 4 are AnyBay
Figure 8. Adapter and cabling for 8 drive bays, where 4 of the bays are AnyBay

3. 16 drive bays, all SAS/SATA

In 16-bay configurations where all 16 drive bays are SAS/SATA drives, you can use either two 8-port SAS/SATA RAID adapters or HBAs or one 16-port SAS/SATA RAID adapter or HBA. These choices are shown in the following figure.

Adapter and cabling for 16x drive bays, all SAS/SATA
Figure 9. Adapter and cabling for 16 drive bays, all SAS/SATA

4. 16 drive bays, where 4 are AnyBay

In 16-drive configurations where four of the bays are AnyBay drive bays, you can elect to have either one 16-port adapter or two 8-port adapters for SAS/SATA connectivity. In addition, the NVMe connectivity depends on whether you have two or four processors installed: for two-processor systems, an NVMe Switch Adapter is required; for four-processor systems, the onboard NVMe ports can be used. The configurations are shown in the following figure.

Adapter and cabling for 16x drive bays, where 4 are AnyBay
Figure 10. Adapter and cabling for 16 drive bays, where 4 of the bays are AnyBay

5. 16 drive bays, where 8 are AnyBay

In 16-drive configurations where eight of the bays are AnyBay drive bays, you can select either one 16-port adapter or two 8-port adapters for SAS/SATA connectivity. In addition, the NVMe connectivity depends on whether you have two or four processors installed: for two-processor systems, two NVMe Switch Adapters are required; for four-processor systems, the onboard NVMe ports is used for four of the AnyBay drive bays and and an NVMe Switch Adapter is needed for the other four AnyBay drive bays. The configurations are shown in the following figure.

Adapter and cabling for 16x drive bays, where 8 are AnyBay
Figure 11. Adapter and cabling for 16 drive bays, where 8 of the bays are AnyBay

Field upgrades

This section describes how customers can upgrade their 8-bay configurations after the initial purchase of the server. The two backplane upgrade kits are listed in the following table.

Table 14. Drive backplane upgrades
Part number Feature code Description
7C57A03998 AXP7 ThinkSystem SR850/SR860 2.5" SATA/SAS 8-Bay BP Kit
7C57A03999 AXP8 ThinkSystem SR850/SR860 2.5" AnyBay 8-Bay BP Kit

The ThinkSystem SR850 2.5" SATA/SAS 8-Bay BP Kit, 7C57A03998, contains the following items:

  • 1x 8-bay SAS/SATA backplane
  • 1x backplane power cable
  • 2x 900mm SAS/SATA cables
  • 2x 720mm SAS/SATA cables
  • 8x 1-bay fillers

The ThinkSystem SR850 2.5" AnyBay 8-Bay BP Kit, 7C57A03999, contains the following items:

  • 1x 8-bay AnyBay backplane (4 SAS/SATA connectors, 4 AnyBay connectors)
  • 1x backplane power cable
  • 1x 900mm SAS/SATA cable
  • 1x 720mm SAS/SATA cable
  • 4x 750mm NVMe cables for use with NVMe Switch Adapter
  • 2x 900mm NVMe cables for use with onboard NVMe ports

In addition to the backplane kits, you will need a RAID adapter or HBA, and for some upgrades you may also need an NVMe adapter. Upgrades needed are listed in the following two tables. Upgrading from a 8-port SAS/SATA adapter to a 16-port SAS/SATA adapter is supported, however that requires removing the existing 8-port adapter.

Tip: The adapters are described in the Controllers for internal storage section.

The following table lists the available upgrades for SR850 servers with a single SAS/SATA backplane (See Configuration 1 above).

Table 15. Upgrades for servers with one 8-bay SAS/SATA backplane
Target configuration Remove existing
8-port adapter
Components to add
Servers with two processors
16x bays (all SAS/SATA) with
2x 8-port adapters (Config 3A)
No 1x SAS/SATA backplane
1x 8-port adapter
16x bays (4x AnyBay) with
2x 8-port adapters, 1x NVMe adapter (Config 4A)
No 1x AnyBay backplane
1x 8-port adapter, 1x NVMe adapter
16x bays (all SAS/SATA) with
1x 16-port adapter (Config 3B)
Yes 1x SAS/SATA backplane
1x 16-port adapter
16x bays (4x AnyBay) with
1x 16-port adapter, 1x NVMe adapter (Config 4B)
Yes 1x AnyBay backplane
1x 16-port adapter, 1x NVMe adapter
Servers with four processors
16x bays (all SAS/SATA) with
2x 8-port adapters (Config 3A)
No 1x SAS/SATA backplane
1x 8-port adapter
16x bays (4x AnyBay) with
2x 8-port adapters (Config 4C)
No 1x AnyBay backplane
1x 8-port adapter, cables to onboard NVMe ports
16x bays (all SAS/SATA) with
1x 16-port adapter (Config 3B)
Yes 1x SAS/SATA backplane
1x 16-port adapter
16x bays (4x AnyBay) with
1x 16-port adapter (Config 4D)
Yes 1x AnyBay backplane
1x 16-port adapter, cables to onboard NVMe ports

The following table lists the available upgrades for SR850 servers with a single SAS/SATA backplane (See Configuration 2 above).

Table 16. Upgrades for servers with one 8-bay AnyBay backplane
Target configuration Remove existing
8-port adapter
Components to add
Servers with two processors
16x bays (4x AnyBay) with
2x 8-port adapters, 1x NVMe adapter (Config 4A)
No 1x SAS/SATA backplane
1x 8-port adapter
16x bays (8x AnyBay) with
2x 8-port adapters, 2x NVMe adapters (Config 5A)
No 1x AnyBay backplane
1x 8-port adapter, 1x NVMe adapter
16x bays (4x AnyBay) with
1x 16-port adapter, 1x NVMe adapter (Config 4B)
Yes 1x SAS/SATA backplane
1x 16-port adapter
16x bays (8x AnyBay) with
2x 8-port adapters, 2x NVMe adapters (Config 5B)
Yes 1x AnyBay backplane
1x 16-port adapter, 1x NVMe adapter
Servers with four processors
16x bays (4x AnyBay) with
2x 8-port adapters (Config 4C)
No 1x SAS/SATA backplane
1x 8-port adapter
16x bays (8x AnyBay) with
2x 8-port adapters, 1x NVMe adapter (Config 5C)
No 1x AnyBay backplane
1x 8-port adapter, 1x NVMe adapter
16x bays (4x AnyBay) with
1x 16-port adapter (Config 4D)
Yes 1x SAS/SATA backplane
1x 16-port adapter
16x bays (8x AnyBay) with
2x 8-port adapters, 1x NVMe adapter (Config 5D)
Yes 1x AnyBay backplane
1x 16-port adapter, 1x NVMe adapter

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 17. M.2 components
Part
number
Feature
code
Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

SED encryption key management with ISKLM

The server supports self-encrypting drives (SEDs) and FIPS 140-2 drives as described in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution. A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server.

The following table lists the part numbers and feature codes for the upgrades.

Table 18. FoD upgrades for SKLM support
Part number Feature code Description
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00D9999 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00FP649 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S

Controllers for internal storage

The SR850 supports internal SAS and SATA drives with the addition of a RAID adapter or HBA. For NVMe support, the server offers two onboard NVMe ports on the processor and memory expansion tray (with four processors) and two ports with the use of an NVMe Switch Adapter.

The following table lists the adapters used for the internal  storage of the SR850 server.

Tip: Unlike System x RAID adapters, no upgrades are available for these RAID adapters. All supported functions are included with the base part numbers.

Table 19. Controllers for internal storage
Part number Feature code Description Number
of ports
Maximum
supported
SAS/SATA HBA
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 8 2
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 16 1
RAID adapters
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 8 2
7Y37A01083* AUNH* ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 8 2
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 8 2
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 16 1
NVMe adapter
7Y37A01081 AUV2 ThinkSystem 1610-4P NVMe Switch Adapter 4 2

* The RAID 730-8i is available in China only

The following table compares the functions of the storage adapters.

Table 20. Comparison of internal storage controllers
Feature 430-8i 430-16i RAID 530-8i RAID 730-8i* RAID 930-8i RAID 930-16i 1610-4P NVMe
Adapter type HBA HBA RAID controller RAID controller RAID controller RAID controller NVMe switch
Part number 7Y37A01088 7Y37A01089 7Y37A01082 7Y37A01083 7Y37A01084 7Y37A01085 7Y37A01081
Form factor PCIe low profile PCIe low profile PCIe HHHL PCIe low profile PCIe HHHL PCIe HHHL PCIe HHHL
Controller chip LSI SAS3408 LSI SAS3416 LSI SAS3408 LSI SAS3108 LSI SAS3508 LSI SAS3516 Broadcom PEX9733
Broadcom equivalent HBA 9400-8i HBA 9400-16i MegaRAID 9440-8i MegaRAID 9361-8i MegaRAID 9460-8i MegaRAID 9460-16i P310W-4P
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS PCIe NVMe
Number of ports 8 16 8 8 8 16 4
Port connectors 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643)
Drive interface SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA NVMe
Drive type HDD, SSD, SED* HDD, SSD, SED* HDD, SED, SSD HDD, SED, SSD HDD, SED, SSD HDD, SED, SSD SSD
Hot-swap drives Yes Yes Yes Yes Yes Yes No
Max devices 8 16 8 8 8 16 4
RAID levels No RAID No RAID 0, 1, 10, 5, 50 0, 1, 10, 5, 50 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60 None
JBOD mode Yes Yes Yes Yes Yes Yes Yes
Cache No No None 1GB (Standard) 2GB (Standard) 4GB (Standard) None
CacheVault cache protection No No No No Yes (Flash) Yes (Flash) No
Performance Accelerator (FastPath) No No Yes No Yes Yes No
SSD Caching (CacheCade Pro 2.0) No No No No No No No
SED support* Yes Yes Yes Yes Yes Yes No

* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.

For more information about the adapters see the product guides in the RAID adapters or HBA sections of the Lenovo Press web site:
https://lenovopress.com/servers/options/raid
https://lenovopress.com/servers/options/hba

Internal drive options

The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.

Tip: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

Table 21. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD 16
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD 16
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD 16
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 16
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 16
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED 16
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED 16
7XB7A00033 B0YX ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD SED 16
Table 22. 2.5-inch hot-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 16
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD 16
Table 23. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Capacity
7N47A00121 AUMK ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD 16
7N47A00122 AUML ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD 16
7N47A00123 B116 ThinkSystem 2.5" PM1633a 15.36TB Capacity SAS 12Gb Hot Swap SSD 16
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Performance (10+ DWPD)
7N47A00124 AUMG ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD 16
7N47A00125 AUMH ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD 16
7N47A00126 AVRB ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD 16
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Mainstream (3-5 DWPD)
7N47A00117 AUMC ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD 16
7N47A00118 AUMD ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD 16
7N47A00119 AVRG ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 16
2.5-inch hot-swap SED SSDs - 12 Gb SAS - Enterprise Performance (10+ DWPD)
7SD7A05754 B11P ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS 16
7SD7A05753 B11Q ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS 16
7SD7A05752 B11R ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS 16
Table 24. 2.5-inch hot-swap 6 Gb SAS/SATA SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD)
7SD7A05765 B10W ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05764 B10X ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05763 B10Y ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05762 B10Z ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05723 B0ZP ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05722 B0ZQ ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05721 B0ZR ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD 16
7SD7A05720 B0ZS ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD 16
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
7N47A00099 AUM8 ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD 16
7N47A00100 AUUZ ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD 16
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 16
7N47A00112 AUM9 ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD 16
7N47A00113 AVCZ ThinkSystem 2.5" PM863a 960GB Entry SATA 6Gb Hot Swap SSD 16
7N47A00114 AVRC ThinkSystem 2.5" PM863a 1.92TB Entry SATA 6Gb Hot Swap SSD 16
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 16
7SD7A05741 B0YZ ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD 16
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 16
7SD7A05739 B0Z1 ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD 16
7SD7A05738 B0Z2 ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD 16
4XB7A08502 B10N ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD 16
Table 25. 2.5-inch U.2 NVMe SSDs
Part number Feature Description Maximum
supported
2.5-inch SSDs - NVMe - Enterprise Performance (10+ DWPD)
7XB7A05923 AWG6 ThinkSystem U.2 PX04PMB 800GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 8
7XB7A05922 AWG7 ThinkSystem U.2 PX04PMB 1.6TB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 8
2.5-inch SSDs - NVMe - Enterprise Mainstream (3-5 DWPD)
7N47A00095 AUUY ThinkSystem U.2 PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 8
7N47A00096 AUMF ThinkSystem U.2 PX04PMB 1.92TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 8
2.5-inch SSDs - NVMe - Enterprise Entry (<3 DWPD)
7N47A00984 AUV0 ThinkSystem U.2 PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 8
7N47A00985 AUUU ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 8

Note: NVMe PCIe SSDs support informed hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 26. M.2 drives
Part number Feature Description Maximum
supported
M.2 SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
7N47A00129 AUUL ThinkSystem M.2 CV1 32GB SATA 6Gbps Non-Hot-Swap SSD 2
7N47A00130 AUUV ThinkSystem M.2 CV3 128GB SATA 6Gbps Non-Hot-Swap SSD 2

Internal backup units

The server does not supports any internal backup units, such as tape drives or RDX drives. 

Optical drives

The server does not supports an internal optical drive.

An external USB optical drive is available, listed in the following table.

Table 27. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

I/O expansion options

The server supports up to 11 PCIe slots including a slot reserved for the M.2 adapter.

Eight slots are on the system board and three (slots 3-5) are through a riser card. A riser card is standard on some models and optional on others. All slots are available with two processors.

The PCIe slots are as follows:

  • Slot 1: PCIe 3.0 x16 (low profile) (CPU 2)
  • Slot 2: PCIe 3.0 x8 (low profile) (CPU 2)
  • Slot 3-5: Riser card slots (see below) (CPU 2)
  • Slot 6: PCIe 2.0 x2 dedicated to M.2 adapter and drives
  • Slot 7: Dedicated to Ethernet LOM phy adapter (CPU 1)
  • Slot 8: PCIe 3.0 x8 (low profile) (CPU 1)
  • Slot 9: PCIe 3.0 x8 (low profile) (CPU 1)
  • Slot 10: PCIe 3.0 x8 (low profile) (CPU 1)
  • Slot 11: PCIe 3.0 x16 (low profile) (CPU 1)

Note: The slot labeled Slot 6 is for the M.2 adapter as described in the M.2 drives section.

Slots 3-5 are implemented using a riser card, and the SR850 supports three different riser cards as listed in the following table.

The following table lists the ordering information for the riser cards.

Table 28. PCI riser card options
Part
number
Feature
code
Description Maximum
supported
7C57A03950 AUR4 ThinkSystem SR850/SR860 x8/x8/x8 PCIe FH Riser 1 Kit 1
7C57A03951 AUR7 ThinkSystem SR850/SR860 x8/x8/x8ML2 PCIe FH Riser 1 Kit 1
7C57A03952 AURB ThinkSystem SR850/SR860 x8/x16ML2 PCIe FH Riser 1 Kit 1

The riser cards listed in the table have the following slots:

  • x8/x8/x8 PCIe FH Riser:
    • Slot 3: PCIe 3.0 x8 FHHL
    • Slot 4: PCIe 3.0 x8 FHHL
    • Slot 5: PCIe 3.0 x8 FHHL
  • x8/x8/x8ML2 PCIe FH
    • Slot 3: PCIe 3.0 x8 FHHL
    • Slot 4: PCIe 3.0 x8 FHHL
    • Slot 5: PCIe 3.0 x8 ML2 FHHL
  • x8/x16ML2 PCIe FH Riser
    • Slot 3: PCIe 3.0 x8 FHHL
    • Slot 4: None
    • Slot 5: PCIe 3.0 x16 ML2 FHHL

Network adapters

The SR850 has an integrated 10Gb Ethernet controller, based on the Intel Ethernet Connection X722. The X722 has the following features:

  • Integrated into the Intel PCH chipset
  • Supports 1GbE or 10GbE connections, depending on the selected LOM Phy adapter
  • Offers VXLAN/NVGRE hardware offloads
  • Supports VMDq and SR-IOV for advanced virtualization
  • Supports iWarp RDMA

To provide connectivity to the X722, the SR850 supports six different LOM (LAN on Motherboard) cards which provide the Ethernet PHY function. Only 1 LOM card can be installed. See Figure 3 for the location of the LOM slot.

The LOM card supports NC-SI to allow the network connection to be shared between the operating system and the XClarity Controller (XCC) management module (also known as IMM, short for integrated management module). The LOM also supports Wake-on-LAN (WOL).

For more information about the X722 controller, see the Lenovo Press product guide:
http://lenovopress.com/LP0654-intel-x722-integrated-controller

The following table lists the supported LOM cards.

Note: None of the LOM cards listed in the table support speeds lower than 1 Gbps.

Table 29. Supported LOM adapters
Part
number
Feature
code
Description Ports Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00544 AUKG ThinkSystem 1Gb 2-port RJ45 LOM 2x RJ45 7 1
7ZT7A00545 AUKH ThinkSystem 1Gb 4-port RJ45 LOM 4x RJ45 7 1
10 Gb Ethernet
7ZT7A00546 AUKJ ThinkSystem 10Gb 2-port SFP+ LOM 2x SFP+ bays 7 1
7ZT7A00547 AUKK ThinkSystem 10Gb 4-port SFP+ LOM 4x SFP+ bays 7 1
7ZT7A00548 AUKL ThinkSystem 10Gb 2-port Base-T LOM 2x RJ45 (10GBASE-T) 7 1
7ZT7A00549 AUKM ThinkSystem 10Gb 4-port Base-T LOM 4x RJ45 (10GBASE-T) 7 1

The SR850 also supports an ML2 card provided a suitable ML2 riser card is installed (see the I/O expansion options section for details). The ML2 card supports NC-SI and WOL. The following table lists the supported ML2 adapters.

VFA5.2 and FCoE support: ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter, 00AG560, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 01CV770 instead.

Table 30. Supported ML2 adapters
Part
number
Feature
code
Description Bus width Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00536 AUKW ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapter PCIe 3.0 x8 5 1
10 Gb Ethernet
00JY940 ATRH Intel X710-DA2 ML2 2x10GbE SFP+ Adapter PCIe 3.0 x8 5 1
7ZT7A00497 AUKQ ThinkSystem Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter PCIe 3.0 x8 5 1
00AG560** AT7U Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter PCIe 3.0 x8 5 1
01CV770 AU7Z Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW PCIe 3.0 x8 5 1
25 Gb Ethernet
7ZT7A00507 AUKU ThinkSystem Mellanox ConnectX-4 Lx ML2 25Gb 2-Port SFP28 Ethernet Adapter PCIe 3.0 x8 5 1
00MN990 ATZR Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter PCIe 3.0 x8 5 1
InfiniBand
7ZT7A00501 AUKR ThinkSystem Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter PCIe 3.0 x8 5 1

* ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter, 00AG560, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 01CV770 instead.

The following table lists additional supported network adapters that can be installed in the regular PCIe slots.

VFA5.2 and FCoE support: ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter, 00AG570, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 00AG580 instead.

Table 31. Supported PCIe Network Adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
10 Gb Ethernet - 10GBase-T
7ZT7A00496 AUKP ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter 1-5, 8, 9, 11 8
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter 1-5, 8, 9, 11 8
10 Gb Ethernet - SFP+
7ZT7A00537 AUKX ThinkSystem X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter 1-5, 8, 9, 11 8
7ZT7A00493 AUKN ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter 3, 4, 5 3
00AG570* AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter 1-5, 8, 9, 11 8
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 1-5, 8, 9, 11 8
25 Gb Ethernet
7ZT7A00505 AUKS ThinkSystem Broadcom NX-E PCIe 25Gb 1-Port SFP28 Ethernet Adapter 1-5, 8, 9, 11 8
01GR250 AUAJ Mellanox ConnectX-4 Lx 2x25GbE SFP28 Adapter 1-5, 8, 9, 11 8
40 Gb Ethernet
00MM950 ATRN Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter 1-5, 8, 9, 11 8
100 Gb Ethernet
00MM960 ATRP Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter 11, 1 2
InfiniBand
7ZT7A00500 AUVG ThinkSystem Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter 1-5, 8, 9, 11 8

* ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter, 00AG570, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support use 00AG580 instead.

For more information, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet

Transceivers and cables

This section lists the transceivers and cables used to connect the network adapters to other devices:

The following table lists the supported 10 Gb Ethernet SFP+ optical transceivers and DAC cables. For multi-port adapters, all adapter ports must have the same type of transceiver or DAC cable selected.

Table 32. Supported optical transceivers and DAC cables - 10 Gb Ethernet
Part number Feature code Description
10 GbE SFP+ LR transceivers (for SFP+ adapters)
00FE331 B0RJ Lenovo 10GBASE-LR SFP+Transceiver
90Y9412 A1PM Lenovo 10Gb/s LR SFP+ XCVR
10 GbE SFP+ SR transceivers (for SFP+ adapters)
46C3447 5053 Lenovo 10GBASE-SR SFP+ Transceiver
49Y4216 0069 Brocade 10Gb SFP+ SR Optical Transceiver
49Y4218 0064 QLogic 10Gb SFP+ SR Optical Transceiver
10 GbE SFP+ DAC cables (for SFP+ adapters)
00D6288 A3RG Lenovo 0.5m Passive SFP+ DAC Cable
90Y9427 A1PH Lenovo 1m Passive SFP+ DAC Cable
00AY764 A51N Lenovo 1.5m Passive SFP+ DAC Cable
00AY765 A51P Lenovo 2m Passive SFP+ DAC Cable
90Y9430 A1PJ Lenovo 3m Passive SFP+ DAC Cable
90Y9433 A1PK Lenovo 5m Passive SFP+ DAC Cable
00D6151 A3RH Lenovo 7m Passive SFP+ DAC Cable

The following table lists the supported 25 GbE transceiver and DAC cables. For multi-port adapters, all adapter ports must have the same type of transceiver or DAC cable selected.

Table 33. Supported optical transceivers and DAC cables - 25 Gb Ethernet
Part number Feature code Description
25 GbE SFP28 transceiver
7G17A03537 AV1B Lenovo 25GBase-SR SFP28 Transceiver
25 GbE SFP28 DAC cables
7Z57A03557 AV1W Lenovo 1m Passive 25G SFP28 DAC Cable
7Z57A03558 AV1X Lenovo 3m Passive 25G SFP28 DAC Cable
7Z57A03559 AV1Y Lenovo 5m Passive 25G SFP28 DAC Cable

The following table lists the optical transceivers and DAC cables that can be used with the supported 40Gb Ethernet adapters listed. For multi-port adapters, all adapter ports must have the same type of transceiver or DAC cable selected.

Table 34. Supported optical transceivers and DAC cables - 40 Gb Ethernet
Part number Feature code Description
40 GbE QSFP+ transceivers (for 40 GbE QSFP+ adapters)
49Y7884 A1DR Lenovo 40GBASE-SR4 QSFP+ Transceiver
40 GbE QSFP+ DAC cables (for 40 GbE QSFP+ adapters)
49Y7890 A1DP Lenovo 1m Passive QSFP+ DAC Cable
49Y7891 A1DQ Lenovo 3m Passive QSFP+ DAC Cable

The following table lists the supported 100 Gb Ethernet SFP+ optical transceivers and DAC cables. For multi-port adapters, all adapter ports must have the same type of transceiver or DAC cable selected.

Table 35. Supported optical transceivers and DAC cables - 100 Gb Ethernet
Part number Feature code Description
100 GbE QSFP28 transceivers
7G17A03539 AV1D Lenovo 100GBase-SR4 QSFP28 Transceiver
100 GbE QSFP28 Active Optical Cables
7Z57A03546 AV1L Lenovo 3m 100G QSFP28 Active Optical Cable
7Z57A03547 AV1M Lenovo 5m 100G QSFP28 Active Optical Cable
7Z57A03548 AV1N Lenovo 10m 100G QSFP28 Active Optical Cable
7Z57A03549 AV1P Lenovo 15m 100G QSFP28 Active Optical Cable
7Z57A03550 AV1Q Lenovo 20m 100G QSFP28 Active Optical Cable
100 GbE SFP28 DAC cables
7Z57A03561 AV1Z Lenovo 1m Passive 100G QSFP28 DAC Cable
7Z57A03562 AV20 Lenovo 3m Passive 100G QSFP28 DAC Cable
7Z57A03563 AV21 Lenovo 5m Passive 100G QSFP28 DAC Cable
100G-to-4x25G Breakout cables
7Z57A03564 AV22 Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03565 AV23 Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable
7Z57A03566 AV24 Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable

The following table lists cables for the Mellanox FDR InfiniBand QSFP adapters.

Table 36. Cables for Mellanox FDR InfiniBand QSFP adapters
Part number Feature code Description
Passive copper cables for Mellanox FDR InfiniBand QSFP adapters
00KF002 ARZB 0.75m Mellanox QSFP Passive DAC Cable
00KF003 ARZC 1m Mellanox QSFP Passive DAC Cable
00KF004 ARZD 1.25m Mellanox QSFP Passive DAC Cable
00KF005 ARZE 1.5m Mellanox QSFP Passive DAC Cable
00KF006 ARZF 3m Mellanox QSFP Passive DAC Cable
Active optical cables for Mellanox FDR InfiniBand QSFP adapters
00KF007 ARYC 3m Mellanox IB FDR Active Optical Fiber Cable
00KF008 ARYD 5m Mellanox IB FDR Active Optical Fiber Cable
00KF009 ARYE 10m Mellanox IB FDR Active Optical Fiber Cable
00KF010 ARYF 15m Mellanox IB FDR Active Optical Fiber Cable
00KF011 ARYG 20m Mellanox IB FDR Active Optical Fiber Cable
00KF012 ARYH 30m Mellanox IB FDR Active Optical Fiber Cable

The following table lists cables for the Mellanox EDR InfiniBand QSFP28 adapters.

Table 37. Cables for Mellanox EDR InfiniBand QSFP28 adapters
Part number Feature code Description
Passive copper cables for Mellanox EDR InfiniBand QSFP28 adapters*
00MP516 ASQT 0.5m Mellanox EDR IB Passive Copper QSFP28 Cable
00MP520 ASQU 0.75m Mellanox EDR IB Passive Copper QSFP28 Cable
00MP524 ASQV 1m Mellanox EDR IB Passive Copper QSFP28 Cable
00MP528 ASQW 1.25m Mellanox EDR IB Passive Copper QSFP28 Cable
00MP532 ASQX 1.5m Mellanox EDR IB Passive Copper QSFP28 Cable
00MP536 ASQY 2m Mellanox EDR IB Passive Copper QSFP28 Cable
00MP560 ASRM 3m Mellanox EDR IB Passive Copper QSFP28 Cable
Active optical cables for Mellanox EDR InfiniBand QSFP28 adapters*
00MP563 ASRN 3m Mellanox EDR IB Active Optical QSFP28 Cable
00MP540 ASQZ 5m Mellanox EDR IB Active Optical QSFP28 Cable
00MP544 ASR0 10m Mellanox EDR IB Active Optical QSFP28 Cable
00MP548 ASR1 15m Mellanox EDR IB Active Optical QSFP28 Cable
00MP552 ASR2 20m Mellanox EDR IB Active Optical QSFP28 Cable
00MP556 ASR3 30m Mellanox EDR IB Active Optical QSFP28 Cable
00MP566 ASRP 50m Mellanox EDR IB Active Optical QSFP28 Cable

* The Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter (00MM960) supports only a subset of the EDR InfiniBand cables listed in the table: 00MP516, 00MP524, 00MP536, and 00MP544.

Fibre Channel host bus adapters

The following table lists the Fibre Channel HBAs supported by SR850 server.

Table 38. Fibre Channel HBAs
Part
number
Feature
code
Description Slots
supported
Maximum
supported
32 Gb Fibre Channel HBAs
7ZT7A00516 AUNS ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter 1-5, 8, 9, 11 8
7ZT7A00518 AUNU ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter 1-5, 8, 9, 11 8
7ZT7A00519 AUNV ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter 1-5, 8, 9, 11 8
7ZT7A00517 AUNT ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter 1-5, 8, 9, 11 8
16 Gb Fibre Channel HBAs
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA 1-5, 8, 9, 11 8
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA 1-5, 8, 9, 11 8
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA 1-5, 8, 9, 11 8
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA 1-5, 8, 9, 11 8

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba

SAS adapters for external storage

The following table lists SAS HBAs and RAID adapters supported by SR850 server for use with external storage.

Table 39. Adapters for external storage
Part
number
Feature
code
Description Slots
supported
Maximum
supported
SAS HBAs
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA 1-5, 8, 9, 11 8
7Y37A01091 AUNN ThinkSystem 430-16e SAS/SATA 12Gb HBA 1-5, 8, 9, 11 8
External RAID adapters
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter 1-5, 8, 9, 11 4

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters and RAID adapters categories:
https://lenovopress.com/servers/options/hba
https://lenovopress.com/servers/options/raid

The following table compares the specifications of the external SAS HBAs and RAID adapters.

Table 40. Comparison of external storage adapters
Feature 430-8e 430-16e 930-8e
Adapter type HBA HBA External RAID
Part number 7Y37A01090 7Y37A01091 7Y37A01087
Controller chip LSI SAS3408 LSI SAS3416 LSI SAS3508
Broadcom equivalent HBA 9400-8e HBA 9400-16e MegaRAID 9480-8e
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 16 8
Port connectors 2x Mini-SAS HD SFF8644 4x Mini-SAS HD SFF8644 2x Mini-SAS HD SFF8644
Drive interface SAS/SATA SAS/SATA SAS,SATA
Drive type HDD/SSD/SED* HDD/SSD/SED* HDD,SED,SSD
Hot-swap drives Yes Yes Yes
Maximum devices 512 (planned: 1024) 512 (planned: 1024) 64 (planned: 216)
RAID levels None None 0/1/10/5/50/6/60
JBOD mode Yes Yes Yes
Cache None None 4GB (Standard)
CacheVault cache protection None None Yes (Flash)
Performance Accelerator (FastPath) No No Yes
SSD Caching (CacheCade Pro 2.0) No No No
SED support* Yes Yes Yes

* SAS HBAs support SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives. SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.

Flash Storage Adapters

The server supports the PCIe Flash Storage adapters listed in the following table.

Table 41.
Part
number
Feature
code
Description Slots
supported
Maximum
supported
7N47A00097 AUUP ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 1-5, 8, 9, 11 8
7N47A00098 AUVY ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 1-5, 8, 9, 11 8
7XB7A05925 AWG8 ThinkSystem HHHL PX04PMC 1.6TB Performance NVMe PCIe 3.0 x4 Flash Adapter 1-5, 8, 9, 11 8
7XB7A05924 AWG9 ThinkSystem HHHL PX04PMC 3.2TB Performance NVMe PCIe 3.0 x4 Flash Adapter 1-5, 8, 9, 11 8

For details about these adapters, see the Lenovo Press product guides in the Flash Adapters category:
https://lenovopress.com/servers/options/ssdadapter

GPU adapters

The SR850 currently does not support any graphics processing units (GPUs).

Power supplies

The server supports up to two redundant hot-swap power supplies.

Installing a second power supply requires either the Processor and Memory Expansion Tray (7B27A03953) or the power interposer (feature AUPZ).

The power interposer enables redundant power support when the Processor and Memory Expansion Tray is not installed. If you do not have the Processor and Memory Expansion Tray installed and want to install two power supplies, then the power interposer card must be installed.

Table 42. Power supply options
Part number Feature
code
Description Maximum
supported
110V AC 220V AC 240V DC
China only†
None* AUPZ SR850 2S Power Paddle (power interposer) 1** Yes Yes Yes
7N67A00883 AUPR 750W Platinum (230V/115V) Power Supply 2 Yes Yes Yes
7N67A00885 AUPS 1100W Platinum (230V/115V) Power Supply 2 Yes Yes Yes
7N67A00886 AUPT 1600W Platinum (230V) Power Supply 2 No Yes Yes

* Configure-to-order only
** Only needed if two power supplies are installed but the Processor and Memory Expansion Tray is not installed
† Support for 240 DC is planned

750W and 1100W power supplies are auto-sensing and support both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. The 1600 W power supply only supports 220V AC power.

For China customers, all three power supplies are 240V DC ready; support is planned for a future date.

Note: At 110 V, the 1100W power supply generates 1050W of power.

Power supply options do not include a line cord.

For server configurations, the inclusion of a power cord is model dependent. Configure-to-order models can be configured without a power cord if desired.

Power cords

Country-specific line cords and rack power cables can be ordered as listed in the following table.

Table 43. Power cords
Part number Feature code Description
Rack cables
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Jumper Cord
Country-specific cables
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
39Y7928 6210 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/250V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
81Y2376 6572 4.3m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13 to IS 6538 (India) Line Cord
81Y2386 6567 4.3m, 10A/250V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/250V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
81Y2380 6493 4.3m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164-1 (South Africa) Line Cord
81Y2379 6576 4.3m, 10A/250V, C13 to SANS 164-1 (South Africa) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7925 6219 2.8m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
81Y2385 6494 4.3m, 12A/250V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8M, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
00WH545 6401 2.8M, 13A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/125V, C13 to NEMA 5-15P (US) Line Cord

110V customers: If you plan to use the ThinkSystem 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Integrated virtualization

The server supports booting from an operating system or hypiervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.

You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
http://shop.lenovo.com/us/en/systems/solutions/alliances/vmware/#tab-vmware_vsphere_esxi

Systems management

The server contains an integrated service processor, XClarity Controller (XCC), which provides advanced control, monitoring, and alerting functions. The XCC is based on the Pilot4 XE401 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Local management

The SR850 offers a front operator panel with key LED status indicators, as shown in the following figure.

SR850 LED status panel
Figure 12. Front operator panel

As an alternative to the front operator panel, (certain models or configure-to-order; not available as a field upgrade), the server supports a pull-out LCD display panel. The LCD display panel allows quick access to system status, firmware, network, and health information. The following figure shows the front operator panel with LCD display.

LCD system information display panel
Figure 13. Front operator panel with LCD display

The LCD display and the function buttons give you access to the following information:

  • Error messages
  • System VPD: machine type & mode, serial number, UUID string
  • System firmware levels: UEFI and XCC firmware
  • XCC network information: hostname, MAC address, IP address, DNS addresses
  • Environmental data: Ambient temperature, CPU temperature, AC input voltage, estimated power consumption
  • System reset action

The front operator panel with LCD display can be ordered as listed in the following table.

Table 44. LCD system information display panel
Part number Feature code Description
None* AUMW Front operator panel with LCD display

* Only available configure-to-order or with predefined models

The server offers light path diagnostics. If an environmental condition exceeds a threshold or if a system component fails, the XCC lights LEDs inside the server to help you diagnose the problem and find the failing part. The SR850 has fault LEDs next to the following components:

  • Each processor
  • Each memory DIMM
  • Each drive bay
  • Each system fan
  • Each power supply

The front of the server also houses an information pull-out tab (also known as the network access tag). See Figure 2 for the location. A label on the tab shows the network information (MAC address and other data) to remotely access XClarity Controller.

System status with XClarity Mobile

The XClarity Mobile app now includes a tethering function where you can connect your Android or iOS device to the server via USB to see the status of the server.

The steps to connect the mobile device are as follows:

  1. Enable USB Management on the server, by holding down the ID button for 3 seconds (or pressing the dedicated USB management button if one is present)
  2. Connect the mobile device via a USB cable to the server's USB port with the management symbol USB Management symbol
  3. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  4. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

Remote management

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SMNP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support

A virtual presence (remote control) capability also comes standard in the server for remote server management. Virtual media (remote drive images) support is optional via a software license upgrade.

The remote control functions include the following:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Capturing blue-screen errors
  • International keyboard mapping support
  • LDAP-based authentication
  • With the XCC Enterprise license upgrade, mapping ISO and diskette IMG image files as virtual drives that are available for use by the server

The Enterprise license upgrade, shown in the following table, enables the following features:

  • Boot Capture
  • Remote mounting of ISO and IMG files
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Power capping
  • License for XClarity Energy Manager
Table 45. XClarity Controller Enterprise Upgrade
Part number Feature code Description
4L47A09133 AVUU ThinkSystem XClarity Controller Advanced to Enterprise Upgrade

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions.

Lenovo XClarity Administrator provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator provides full management function to ThinkSystem servers, including the following:

  • Discovery
  • Inventory
  • Monitoring and alerting
  • Call home
  • Centralized user management
  • Cryptography modes, server certificates, and encapsulation
  • Configuration patterns
  • Operating system deployment
  • Firmware updates

For more information about Lenovo XClarity Administrator, including ordering part numbers, see the Lenovo XClarity Administrator Product Guide:
https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

Lenovo XClarity Provisioning Manager provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system setting, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager is an agent-free, web-based console that provides power management for ThinkSystem servers as well as System x and ThinkServer systems. It enables server density and data center capacity to be increased through the use of power capping.

Lenovo XClarity Energy Manager is a licensed product. A single-node XClarity Energy Manager license is included with the XClarity Controller Enterprise (XCC Enterprise) upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 46. Lenovo XClarity Energy Manager
Description Part number Maximum supported
4L40E51621 Lenovo XClarity Energy Manager Node License 1 node
4L40E51622 Lenovo XClarity Energy Manager Node License Pack 5 nodes
4L40E51623 Lenovo XClarity Energy Manager Node License Pack 50 nodes

Security

The server offers the following security features:

  • Administrator and power-on password
  • Trusted Platform Module (TPM) supporting both TPM 1.2 and TPM 2.0
  • Optional Trusted Cryptographic Module (TCM), available only in China
  • Lockable top cover to help prevent access to internal components
  • Optional lockable front security bezel
  • Self-encrypting drives with support for IBM Security Key Lifecycle Manager

The TCM module, available only for China customers, is installed in a dedicated socket on the system board, as shown in Figure 4.

The optional lockable front bezel is shown in the following figure and includes a key that enables you to secure the bezel over the drives and system controls thereby reducing the chance of unauthorized or accidental access to the server.

SR850 front security bezel
Figure 14. Lockable front security bezel

The dimensions of the security bezel are:

  • Width: 437 mm (17.2 in.)
  • Height: 87 mm (3.4 in.)
  • Width: 23 mm (0.9 in.)

The following table lists the security options for the server.

Table 47. Security features
Part number Feature code Description
None* AVKE ThinkSystem Trusted Cryptographic Module (China customers only)
7Z17A02580 AURX ThinkSystem 2U Security Bezel

* The Trusted Cryptographic Module (TCM) for China customers is not available as a field upgrade. The component is CTO on pre-configured models only.

For SED drives and IBM Security Key Lifecycle Manager support see the SED encryption key management with ISKLM section.

Rack installation

The following table lists the rack installation options that are available for the server.

The Front VGA Connector Upgrade Kit allows you to upgrade your server by adding a VGA video port to the front of the server (if the server does not already come with a front VGA port). When the front VGA is in use, the rear VGA port is automatically disabled.

Table 48. Rack installation options
Option Feature Code Description
Optional front VGA port
7X97A03954 AUPX ThinkSystem SR850 Front VGA Connector Upgrade Kit
Rail slides
7M27A05700 AXCH ThinkSystem Toolless Slide Rail Kit with 2U CMA
7M27A05702 AXCA ThinkSystem Toolless Slide Rail
4M17A07274 AXFN ThinkSystem Tooled Slide Rail
4M17A07273 AXFM ThinkSystem Toolless Friction Rail
Cable Management Arms
4M17A07275 AXFU ThinkSystem 2U CMA Upgrade Kit for Tooled Slide Rail
7M27A05698 None* ThinkSystem 2U CMA Upgrade Kit for Toolless Slide Rail

* This kit is for field upgrades only; for CTO use the rail kit with CMA, feature AXCH

The following table summarizes the rail kit features and specifications.

Table 49. Rail kit features and specifications summary
Feature ThinkSystem Toolless Slide Rail ThinkSystem Tooled Slide Rail ThinkSystem Toolless Friction Rail
Part number 7M27A05702 (no CMA)
7M27A05700 (with CMA)
4M17A07274 4M17A07273
Rail type Full-out slide (ball bearing) Full-out slide (ball bearing) Half-out slide (friction)
Toolless installation Yes No Yes
Cable Management
Arm (CMA) support
Yes
(7M27A05700 only)
Optional
(4M17A07275)
No
In-rack server maintenance Yes Yes No
1U PDU support Yes Yes Yes
0U PDU support Limited* Limited* Limited**
Rack type Lenovo and IBM 4-post,
IEC standard-compliant
Lenovo and IBM 4-post,
IEC standard-compliant
Lenovo and IBM 4-post,
IEC standard-compliant
Mounting holes Square or round Square, round, or threaded Square or round
Mounting flange thickness 2 mm - 3.3 mm
(0.08 - 0.13 in.)
2 mm - 3.3 mm
(0.08 - 0.13 in.)
2 mm - 3.3 mm
(0.08 - 0.13 in.)
Distance between front
and rear mounting flanges
610 mm - 864 mm
(24 - 34 in.)
610 mm - 864 mm
(24 - 34 in.)
610 mm - 864 mm
(24 - 34 in.)
Rail length*** 730 mm (28.74 in.) 837 mm (32.9 in.) 728 mm (28.7 in.)

* For 0U PDU support, the rack must be at least 1100 mm (43.31 in.) deep without a CMA, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** For 0U PDU support with the friction rail kit, the rack must be at least 1000 mm (39.37 in.) deep.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.

Operating system support

The server supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2016
  • SUSE Linux Enterprise Server 11 SP4
  • SUSE Linux Enterprise Server 12 SP2
  • Red Hat Enterprise Linux 6.9
  • Red Hat Enterprise Linux 7.3
  • VMware ESXi 6.0 U3
  • VMware ESXi 6.5

For details about the specific versions and service levels supported and any other prerequisites, see the Operating System Interoperability Guide: http://lenovopress.com/osig

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 50. VMware ESXi preload
Part number Feature code Description
CTO only AXFT VMware ESXi 6.5 (factory installed)
CTO only AXFS VMware ESXi 6.0 U3 (factory installed)

Physical and electrical specifications

Dimensions and weight:

  • Height: 86 mm (3.4 in.)
  • Width: 445 mm (17.5 in.)
  • Depth: 776 mm (30.5 in.)
  • Approximate weight, minimum 18 kg (40 lb.), fully configured 27 kg (59.6 lb.)

Electrical specifications:

  • Electrical - Input voltage
    • 100 - 127 (nominal) V AC, 50 Hz or 60 Hz
    • 200 - 240 (nominal) V AC, 50 Hz or 60 Hz
    • 180 - 300 V DC (support is planned; China only)
  • Power consumption:
    • 100-127 V:
      • 750W power supply: 8.4 kVA
      • 1100W power supply: 12 kVA
    • 200-240 V:
      • 750W power supply: 4.1 kVA
      • 1100W power supply: 6 kVA
      • 1600W power supply: 8.7 kVA

Operating environment

The ThinkSystem SR850 server complies with ASHRAE Class A2 specifications, and depending on the hardware configuration, also complies with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.

To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements:

  • Two power supplies installed
  • NVMe drives not installed
  • PCIe flash storage adapters not installed

In addition, CPU core speed may be reduced depending on the processor selected. 

The server is supported in the following environment:

  • Air temperature:
    • Operating:
      • ASHARE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
      • ASHARE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
      • ASHARE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
    • Server off: 5°C to 45°C (41°F to 113°F)
    • Shipment/storage: -40°C to 60°C (-40°F to 140°F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Operating
      • ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
      • ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
      • ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
    • Shipment/storage: 8% to 90% 

The server generates the following heat and noise:

  • Heat/thermal output:
    • Minimum configuration: 454 BTU/hr, 133 W
    • Maximum configuration: 5118 BTU/hr, 1500 W
  • Noise level (LWAm)
    • Sound power, idling: 5.2 bels (minimum), 5.8 bels (typical), 6.4 bels (maximum)
    • Sound power, operating: 5.8 bels (minimum), 6.8 bels (typical), 7.0 bels (maximum)

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg  - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Warranty

The SR850 has a 1-year or 3-year warranty based on the machine type of the system:

  • 7X18: 1 year warranty
  • 7X19: 3 year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units, FRUs, only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a predefined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, go to the Data Center Advisor and Configurator (formerly known as LESC) website http://lesc.lenovo.com, then do the following:

  1. In the Customize a Model box in the middle of the page, select the Services option in the Customization Option dropdown menu
  2. Enter the machine type & model of the system
  3. From the search results, you can click either Deployment Services or Support Services to view the offerings

The following table explains warranty service definitions in more detail.

Table 51. Warranty service definitions
Term Description
Onsite Service If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location. 
Parts Delivered If a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo will send a replacement CRU to arrive at your location. If a problem with your product cannot be resolved via telephone and a FRU part is required, a Service Technician will be dispatched to arrive at your location.  
Technician Installed Parts If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location.
Hours of coverage
  • 9x5: 9 hours/day, 5 days/week, during normal business hours, excluding local public & national holidays
  • 24x7: 24 hours per day, 7 days per week, 365 days per year.
Response time target 2 hours, 4 hours, or Next Business Day: The time period from when the telephone based troubleshooting is completed and logged, to the delivery of the CRU or arrival of a Service Technician and part at the Customer’s location for repair.
Committed Repair 6 hours: The time period between the service request registration in Lenovo’s call management system and the restoration of the product to conformance with its specification by a Service Technician. 

The following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • Three, four, or five years of 9x5 or 24x7 service coverage
    • Parts delivered or technician installed parts from next business day to 4 or 2 hours
    • Committed repair service
    • Warranty extension of up to 5 years
    • Post warranty extensions
  • Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.

    • Priority handling to meet defined time frames to restore the failing machine to good working condition
    • 24x7x6 committed repair: Service performed 24 hours per day, 7 days per week, within 6 hours
  • YourDrive YourData

    Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions.

  • Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.

  • Enterprise Software Support

    Lenovo Enterprise Server Software Support can help you troubleshoot your entire server software stack. Choose support for server operating systems from Microsoft, Red Hat, SUSE, and VMware; Microsoft server applications; or both operating systems and applications. Support staff can help answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

    In addition, you can access hardware “how to” support for ThinkSystem servers. Staff can help resolve hardware problems not covered under warranty, refer you to the right documentation and publications, provide corrective service information for known defects, and transfer you to a hardware support call center if needed.

  • Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. Your new systems will be configured and ready for your software installation.

Regulatory compliance

The SR850 server conforms to the following standards:

  • Energy Star v2.1
  • FCC: Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 6, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • China CCC (GB4943.1), GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • Korea KN32, Class A; KN35
  • Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011(for Safety); TP TC 020/2011(for EMC)
  • CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, and EN61000-3-3)
  • CISPR 32, Class A
  • TUV-GS (EN60950-1 /IEC60950-1, EK1-ITB2000)
  • India BIS certification

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

The following table lists the 6 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the server for storage expansion.

Table 52. E1012 and E1024 external drive enclosure models
Part number Description
64111B1 Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD
64111B2 Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD
64111B3 Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD
64111B4 Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD

For details about supported drives and cables for the Lenovo Storage E1012 and E1024, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0043

The following table lists the standard models of the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.

Table 53. D1212 and D1224 standard models
Part number Description
LFF models
4587A11* D1212 LFF Chassis, Dual 3-port ESMs (US English documentation)
4587A1C^ D1212 LFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)
4587A1J** D1212 LFF Chassis, Dual 3-port ESMs (Japanese documentation)
SFF models
4587A31* D1224 SFF Chassis, Dual 3-port ESMs (US English documentation)
4587A3C^ D1224 SFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)
4587A3J** D1224 SFF Chassis, Dual 3-port ESMs (Japanese documentation)

* Available worldwide (except China and Japan)
^ Available only in China
** Available only in Japan

The following table lists the TopSeller models of the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.

Table 54. D1212 and D1224 TopSeller models
Part number Description
Brazil and Latin America - LFF models
4587EAU D1212 LFF Chassis, Dual 3-port ESMs, 4x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EBU D1212 LFF Chassis, Dual 3-port ESMs, 4x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587ECU D1212 LFF Chassis, Dual 3-port ESMs, 4x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587EDU D1212 LFF Chassis, Dual 3-port ESMs, 4x 8TB 3.5" HDDs, 4x 0.5m SAS cables
4587EEU D1212 LFF Chassis, Dual 3-port ESMs, 8x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EFU D1212 LFF Chassis, Dual 3-port ESMs, 8x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587EGU D1212 LFF Chassis, Dual 3-port ESMs, 8x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587EHU D1212 LFF Chassis, Dual 3-port ESMs, 8x 8TB 3.5" HDDs, 4x 0.5m SAS cables
4587EIU D1212 LFF Chassis, Dual 3-port ESMs, 12x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EJU D1212 LFF Chassis, Dual 3-port ESMs, 12x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587EKU D1212 LFF Chassis, Dual 3-port ESMs, 12x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587ELU D1212 LFF Chassis, Dual 3-port ESMs, 12x 8TB 3.5" HDDs, 4x 0.5m SAS cables
Brazil and Latin America - SFF models
4587E6U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables
4587E2U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables
4587E4U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables
4587E5U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 1x 0.5m SAS cable
4587E1U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables
4587E3U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables

For details about supported drives and cables for the Lenovo Storage D1212 and D1224, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0512

The following table lists the standard models of the 12 Gbps SAS external high density drive enclosures offered by Lenovo.

Table 55. D3284 standard models
Description Part number
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 641311F
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 641312F
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 641313F
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 641314F

The following table lists the TopSeller models of the 12 Gbps SAS external high density drive enclosures offered by Lenovo.

Table 56. D3284 TopSeller models
Description Part number
Lenovo Storage D3284 High Density Expansion Enclosure 6413E5F
Lenovo Storage D3284 4TB x 42 HD Expansion Enclosure 6413E1H
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 6413E1F
Lenovo Storage D3284 6TB x 42 HD Expansion Enclosure 6413E2H
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 6413E2F
Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure 6413E3H
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 6413E3F
Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure 6413E4H
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 6413E4F

For details about supported drives, adapters, and cables for the Lenovo Storage D3284, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0513

External storage systems

The following table lists the NAS and SAN external storage systems that are offered by Lenovo.

Table 57. External storage systems
Part number Description
Lenovo ThinkSystem DS Series Storage (SAS host connectivity)
4599A41* Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (US English documentation)
4599A4C^ Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Simplified Chinese documentation)
4599A4J** Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Japanese documentation)
4599A21* Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (US English documentation)
4599A2C^ Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)
4599A2J** Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Japanese documentation)
4617A41* Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (US English documentation)
4617A4C^ Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Simplified Chinese documentation)
4617A4J** Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Japanese documentation)
4617A21* Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (US English documentation)
4617A2C^ Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)
4617A2J** Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Japanese documentation)
4619A21* Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (US English documentation)
4619A2C^ Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Simplified Chinese documentation)
4619A2J** Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Japanese documentation)
Lenovo ThinkSystem DS Series Storage (iSCSI or FC host connectivity)
4599A31* Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (US English documentation)
4599A3C^ Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4599A3J** Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4599A11* Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (US English documentation)
4599A1C^ Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4599A1J** Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4617A31* Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (US English documentation)
4617A3C^ Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4617A3J** Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4617A11* Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (US English documentation)
4617A1C^ Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
4617A1J** Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation)
4619A11* Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (US English documentation)
4619A1C^ Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation)
Lenovo Storage V Series (iSCSI, FC, or FCoE host connectivity)
6535C1D Lenovo Storage V3700 V2 LFF Control Enclosure
6535EC1 Lenovo Storage V3700 V2 LFF Control Enclosure (TopSeller)
6535C2D Lenovo Storage V3700 V2 SFF Control Enclosure
6535EC2 Lenovo Storage V3700 V2 SFF Control Enclosure (TopSeller)
6535C3D Lenovo Storage V3700 V2 XP LFF Control Enclosure
6535EC3 Lenovo Storage V3700 V2 XP LFF Control Enclosure (TopSeller)
6535C4D Lenovo Storage V3700 V2 XP SFF Control Enclosure
6535EC4 Lenovo Storage V3700 V2 XP SFF Control Enclosure (TopSeller)
6536C12 Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S
6536C32 Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S
6536C22 Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S
6536C42 Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S
6536B1F Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S
6536B2F Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S
IBM Storwize for Lenovo (iSCSI, FC, or FCoE host connectivity)
6096CU2^ IBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit
6096CU3^ IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit
6099L2C IBM Storwize V3700 3.5-inch Storage Controller Unit
6099S2C IBM Storwize V3700 2.5-inch Storage Controller Unit
6195SC5† IBM Storwize V7000 2.5-inch Storage Controller Unit, w/3 Yr S&S (Model 524)
6195SCL‡ IBM Storwize V7000 2.5-inch Storage Controller Unit, w/3 Yr S&S (LA) (Model 524)
61951F1† IBM Storwize V7000 2.5-inch Storage Controller Unit, w/5 Yr S&S (Model 524)
61951FL‡ IBM Storwize V7000 2.5-inch Storage Controller Unit, w/5 Yr S&S (LA) (Model 524)
6195C32† IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA (Model HC1 [Gen2+])
6195C3L‡ IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA (Model HC1 [Gen2+])
6195C52† IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA (Model HC1 [Gen2+])
6195C5L‡ IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA (Model HC1 [Gen2+])
Lenovo Storage DX8200 Series (S3 cloud storage)
5120D1x Lenovo Storage DX8200C 56TB (14x 4TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
5120D2x Lenovo Storage DX8200C 84TB (14x 6TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
5120D3x Lenovo Storage DX8200C 112TB (14x 8TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
5120D4x Lenovo Storage DX8200C with 14x 10TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S
Lenovo Storage DX8200 Series (NAS, iSCSI connectivity; optional FC connectivity)
5135A3x Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 3yr SW S&S
5135J3x Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 4yr SW S&S
51351Wx Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 5yr SW S&S
5135B3x Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 3yr SW S&S
5135L3x Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 4yr SW S&S
51352Wx Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 5yr SW S&S
5135C3x Lenovo Storage DX8200D Storage Virtualization High, 64TB, 3yr SW S&S
5135M3x Lenovo Storage DX8200D Storage Virtualization High, 64TB, 4yr SW S&S
51353Wx Lenovo Storage DX8200D Storage Virtualization High, 64TB, 5yr SW S&S
5135D3x Lenovo Storage DX8200D ServerSAN Entry, 8TB, 3yr SW S&S
5135N3x Lenovo Storage DX8200D ServerSAN Entry, 8TB, 4yr SW S&S
51354Wx Lenovo Storage DX8200D ServerSAN Entry, 8TB, 5yr SW S&S
5135F3x Lenovo Storage DX8200D ServerSAN Mid, 16TB, 3yr SW S&S
5135P3x Lenovo Storage DX8200D ServerSAN Mid, 16TB, 4yr SW S&S
51355Wx Lenovo Storage DX8200D ServerSAN Mid, 16TB, 5yr SW S&S
5135G3x Lenovo Storage DX8200D ServerSAN High, 32TB, 3yr SW S&S
5135Q3x Lenovo Storage DX8200D ServerSAN High, 32TB, 4yr SW S&S
51356Wx Lenovo Storage DX8200D ServerSAN High, 32TB, 5yr SW S&S
5128C1x Lenovo Storage DX8200N with 1x N2226 HBA
5128C2x Lenovo Storage DX8200N with 2x N2226 HBAs

* Available worldwide (except China and Japan).
^ Available only in China.
** Available only in Japan.
† Available worldwide except Latin America.
‡ Available only in Latin America.

For more information, see the list of Product Guides in the following categories:

Top-of-rack Ethernet switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 58. Ethernet LAN switches
Part number Description
1 Gb Ethernet switches
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
7159G64 Lenovo RackSwitch G8264 (Rear to Front)
7159DRX Lenovo RackSwitch G8264CS (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
40 Gb Ethernet switches
7159BRX Lenovo RackSwitch G8332 (Rear to Front)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

The following table lists the Fibre Channel SAN switches that are offered by Lenovo and can be used with this system.

Table 59. Fibre Channel SAN switches
Part number Description
8 Gb FC
3873AR3 Lenovo B300, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit
3873AR4 Lenovo B6505, 12 ports activated, 12x 8Gb SWL SFPs, 1 PS, Rail Kit
3873BR2 Lenovo B6510, 24 ports activated, 24x 8Gb SWL SFPs, 2 PS, Rail Kit
16 Gb FC
6559D2Y Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit
6559D1Y Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit
3873AR5 Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit
3873BR3 Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit
32 Gb FC
6559D3Y Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit
6415G11 Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit
6415G2A Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit
6684B2A Lenovo ThinkSystem DB400D 32Gb FC Director, up to 192 ports, 8U, Enterprise SW
6682B1A Lenovo ThinkSystem DB800D 32Gb FC Director, up to 384 ports, 14U, Enterprise SW

For more information, see the list of Product Guides in the Rack SAN Switches category:
http://lenovopress.com/storage/switches/rack?rt=product-guide

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 60. Uninterruptible power supply units
Part number Description
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 61. Power distribution units
Part number Description
0U Basic PDUs
00YJ776 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord
00YJ777 0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord
00YJ778 0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord
00YJ779 0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord
Switched and Monitored PDUs
00YJ780 0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord
00YJ781 0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord
00YJ782 0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord
00YJ783 0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord
46M4002 1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)
46M4003 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
46M4004 1U 12 C13 Switched and Monitored DPI PDU (without line cord)
46M4005 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71762NX Ultra Density Enterprise C19/C13 PDU Module (without line cord)
71763NU Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 DPI C13 Enterprise PDU+ (without line cord)
39Y8941 DPI Single Phase C13 Enterprise PDU (without line cord)
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 DPI Single Phase C19 Enterprise PDU (without line cord)
39Y8923 DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord
Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord
39Y8939 DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord
39Y8934 DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8940 DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8935 DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 DPI 100-127V PDU with Fixed NEMA L5-15P line cord
Line cords for PDUs that ship without a line cord
40K9611 DPI 32a Line Cord (IEC 309 3P+N+G)
40K9612 DPI 32a Line Cord (IEC 309 P+N+G)
40K9613 DPI 63a Cord (IEC 309 P+N+G)
40K9614 DPI 30a Line Cord (NEMA L6-30P)
40K9615 DPI 60a Cord (IEC 309 2P+G)
40K9617 DPI Australian/NZ 3112 Line Cord
40K9618 DPI  Korean 8305 Line Cord

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

The following table lists the supported rack cabinets.

Table 62. Rack cabinets
Part number Description
93072RX 25U Standard Rack
93072PX 25U Static S2 Standard Rack
93634PX 42U 1100mm Dynamic Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93604PX 42U 1200mm Deep Dynamic Rack
93614PX 42U 1200mm Deep Static Rack
93084EX 42U Enterprise Expansion Rack
93084PX 42U Enterprise Rack
93074RX 42U Standard Rack
Withdrawn rack cabinets
201886X* 11U Office Enablement Kit
93604EX* 42U 1200mm Deep Dynamic Expansion Rack
93614EX* 42U 1200mm Deep Static Expansion Rack
93074XX* 42U Standard Rack Extension
93624PX* 47U 1200mm Deep Static Rack
93624EX* 47U 1200mm Deep Static Expansion Rack
93634BX* PureFlex System 42U Expansion Rack
93634DX* PureFlex System 42U Expansion Rack
93634AX* PureFlex System 42U Rack
93634CX* PureFlex System 42U Rack

* Withdrawn from marketing

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp0658-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM console options

The following table lists the supported KVM consoles, keyboards, and KVM switches.

Table 63. Console keyboards
Part number Description
Consoles
17238BX 1U 18.5" Standard Console (without keyboard)
Console keyboards
00MW310 Lenovo UltraNav Keyboard USB - US Eng
46W6713 Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2
46W6714 Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
46W6715 Keyboard w/ Int. Pointing Device USB - Chinese/US 467 RoHS v2
46W6716 Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
46W6717 Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
46W6718 Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
46W6719 Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
46W6720 Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
46W6721 Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
46W6722 Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
46W6723 Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
46W6724 Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
46W6725 Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
46W6726 Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
46W6727 Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
46W6728 Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
46W6729 Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
46W6730 Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
46W6731 Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
46W6732 Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
46W6733 Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
46W6734 Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
46W6735 Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
46W6736 Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
46W6737 Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
46W6738 Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
46W6739 Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
46W6740 Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2
46W6741 Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
Console switches
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Console switch cables
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option (4 Pack UCO)
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

http://www.lenovofs.com

Related product families