Lenovo Storage D3284 External High Density Drive Expansion EnclosureProduct Guide

Abstract

The Lenovo Storage D3284 High Density Expansion Enclosure offers 12 Gbps SAS direct-attached storage expansion capabilities that are designed to provide density, speed, scalability, security, and high availability for medium to large businesses. The D3284 delivers enterprise-class storage technology in a cost-effective dense solution with flexible drive configurations of up to 84 drives in 5U and RAID or JBOD (non-RAID) host connectivity.

This product guide provides essential technical and pre-sales information on the D3284 drive enclosure offering, its key features and specifications, components and options, and configuration guidelines.

This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the D3284 and consider its use in IT solutions.

Change History

Changes in the November 22 update:

  • Added SAS Zoning
  • Added SAS Y-cables
  • Updated Warranty services

Introduction

The Lenovo Storage D3284 High Density Expansion Enclosure offers 12 Gbps SAS direct-attached storage expansion capabilities that are designed to provide density, speed, scalability, security, and high availability for medium to large businesses. The D3284 delivers enterprise-class storage technology in a cost-effective dense solution with flexible drive configurations of up to 84 drives in 5U rack space and RAID or JBOD (non-RAID) host connectivity.

The D3284 expansion unit is designed for a wide range of workloads, including big data and analytics, video surveillance, private and hybrid clouds, file and print serving, and backup and archiving. The D3284 is also well-suited for software defined storage (SDS) and Windows Storage Spaces.

Lenovo Storage D3284 HD Expansion Enclosure
Figure 1. Lenovo Storage D3284 HD Expansion Enclosure

Did you know?

The D3284 expansion enclosures support 12 Gbps SAS connectivity, which doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.

With support for daisy chaining, the D3284 expansion enclosures can be scaled up to 5.16 PB for capacity-optimized configurations.

The D3284 expansion enclosures allow daisy chaining with D1212 and D1224 expansion enclosures: Up to two D3284 and two D1212 or one D1224 drive enclosures is supported in a single chain.

Key features

Key features and benefits provided by the D3284 storage expansion enclosures include:

  • Versatile, scalable storage expansion with dual Environmental Service Module (ESM) configurations for high availability and performance
  • Flexible host connectivity to match diverse client needs for direct attach storage with support for 6 Gb or 12 Gb SAS RAID adapters for advanced data protection or 6 Gb or 12 Gb SAS Host Bus Adapters (HBAs) for maximum JBOD performance
  • 12 Gb SAS drive-side connectivity and storage density with support for 84x 3.5-inch large form factor (LFF) drives in a 5U rack space
  • Scalability of up to 336 drives per HBA with the attachment of up to four D3284 daisy-chained expansion enclosures to satisfy growing needs for storage capacity and performance
  • Flexibility in daisy chaining of up to two D3284 and two D1212 or one D1224 drive enclosures
  • Flexibility in storing data on high performance SAS SSDs or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types on a single HBA to perfectly meet performance and capacity requirements for various workloads
  • Support multiple host attachments (application-specific)

The D3284 drive enclosures are designed to support a wide range of data storage requirements, from highly utilized applications to high-capacity, low usage applications.

The following SAS drives are supported by the D3284:

  • High-capacity, archival-class nearline disk drives: 4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm
  • High performance solid-state drives (10 drive writes per day [DWD] and 3 DWD): 400 GB
  • Capacity-optimized solid-state drives (1 drive write per day [DWD]): 3.84 TB, 7.68 TB, and 15.36 TB

Additional drives and expansion units are designed to be dynamically added with virtually no downtime (operating system dependent), helping to quickly and seamlessly respond to growing capacity demands.

The D3284 expansion enclosures are designed to offer high levels of system and data availability with the following technologies:

  • Dual ESMs provide redundant paths from a supported HBA to the drives in the enclosures for I/O load balancing and failover
  • Dual-port drives (both HDDs and SSDs) with automatic drive failure detection
  • Redundant hardware, including host ports, ESMs, power supplies, and cooling fans
  • Hot-swappable and customer replaceable components, including ESMs, power supplies, cooling fans, and drives

Components and connectors

The following figures show the front of the D3284 drive expansion enclosure.

Front view of the D3284 drive enclosure
Figure 2. Front view of the D3284 drive enclosure

The following figures show the rear of the D3284 drive expansion enclosure.

Rear view of the D3284 drive enclosure
Figure 3. Rear view of the D3284 drive enclosure

Note: The ESMs (shown in Figure 3) have additional service ports with a specialized connector, and these ports are reserved for use by a Lenovo service technician.

System specifications

The following table lists the D3284 system specifications.

Table 1. System specifications
Attribute Specification
Form factor 5U rack mount
Number of ESMs 2
Expansion ports 3x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (A, B, C) per ESM
Drive bays 84 LFF hot-swap drive bays in two drawers. Each drawer has three drive rows, and each row has 14 drives. Up to 4x D3284 enclosures can be daisy chained on a supported adapter for a total of up to 336 LFF drives.
Drive technologies NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs is supported within an enclosure/drawer, but not within a row.
Drive connectivity Dual-ported 12 Gb SAS drive attachment infrastructure.
Drives
  • 4 TB, 6 TB, 8 TB, 10 TB, and 12 TB 7.2K rpm 12 Gb NL SAS HDDs
  • 400 GB 12 Gb SAS SSDs (3 DWD and 10 DWD)
  • 3.84 TB, 7.68 TB, and 15.36 TB 12 Gb SAS SSDs (1 DWD)
Storage capacity Up to 5.16 PB (336x 15.36 TB SAS SSDs)
Host adapters RAID controllers:
  • M5120 (8-port 6 Gbps SAS, 2x SFF-8088 connectors)
  • M5225 (8-port 12 Gbps SAS, 2x SFF-8644 connectors)
  • 9286CV-8e (8-port 6 Gbps SAS, 2x SFF-8088 connectors)
  • 9380-8e (8-port 12 Gbps SAS, 2x SFF-8644 connectors)
Host bus adapters (non-RAID):
  • ThinkSystem 430-8e HBA (2-port 12 Gb SAS)
  • ThinkSystem 430-16e HBA (4-port 12 Gb SAS)
  • N2125 (8-port 6 Gbps SAS, 2x SFF-8088 connectors)
  • N2225 (8-port 12 Gbps SAS, 2x SFF-8644 connectors)
  • N2226 (16-port 12 Gbps SAS, 2x SFF-8644 connectors)
  • 9300-8e (8-port 12 Gbps SAS, 2x SFF-8644 connectors)
Host operating systems Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere ESXi 5.5 and 6.0.
Cooling N+1 redundant cooling with five hot-swap fans.
Power supply Two redundant hot-swap 2214 W AC power supplies.
Hot-swap parts ESMs, drives, sideplanes, power supplies, and fans.
Management interfaces SAS Enclosure Services, 10/100 Mb Ethernet for external management.
Partitioning SAS zoning.
Warranty Three-year customer-replaceable unit, parts delivered limited warranty with 9x5 next business day response.
Service and support Optional warranty service upgrades are available through Lenovo: Technician installed parts, 24x7 coverage, 2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty extensions, YourDrive YourData, hardware installation.
Dimensions Height: 221 mm (8.7 in), width: 447 mm (17.6 in), depth: 933 mm (36.7 in)
Maximum weight 131 kg (288.8 lb)

Models

The following table lists the relationship models of the D3284 drive enclosures.

Table 2. D3284 relationship models
Description Part number
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 641311F
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 641312F
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 641313F
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 641314F

The following table lists the TopSeller models of the D3284 drive enclosures.

Table 3. D3284 TopSeller models
Description Part number
Lenovo Storage D3284 High Density Expansion Enclosure 6413E5F
Lenovo Storage D3284 4TB x 42 HD Expansion Enclosure 6413E1H
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 6413E1F
Lenovo Storage D3284 6TB x 42 HD Expansion Enclosure 6413E2H
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 6413E2F
Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure 6413E3H
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 6413E3F
Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure 6413E4H
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 6413E4F

The part numbers for the D3284 drive enclosures include the following items:

  • One chassis with the following components:
    • Dual 3-port environmental service modules
    • Two drawers
    • Two power supplies
    • Five cooling fans
    • Drives (select models; see Table 2 and Table 3 for details)
  • Two 2m, 16A/100-250V, C19 to IEC 320-C20 rack power cables
  • Lenovo Storage 12Gb High Density Rack Mount Kit - Rails 25"-33"
  • Documentation package

Host connectivity

The D3284 drive enclosures support dual environmental service module (ESM) configurations. Each ESM has three universal 12 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors) labeled A, B, and C. These ports are used for connections to a supported SAS RAID controller or SAS HBA installed in a server and for daisy chaining the D3284 enclosures between each other or with the D1212 or D1224 enclosures.

Port A on each ESM is used for connecting the host's external SAS ports to the enclosure, or for connecting Port C on each ESM in the adjacent enclosure for daisy chaining.

Port B on each ESM is used for connecting the host's external SAS ports to the enclosure. Daisy-chaining does not use Port B for connections between adjacent enclosures.

Port C on each ESM is used for connecting the host's external SAS ports to the enclosure, or for connecting Port A on each ESM in the adjacent enclosure for daisy chaining.

Up to four D3284 drive enclosures, or two D3284 and two D1212 drive enclosures, or two D3284 and one D1224 drive enclosures can be daisy-chained with support for up to four hosts attached to the chain. Without daisy-chaining, a standalone D3284 drive enclosure can support up to six directly attached hosts. In addition, up to two D3284 and up to two D1212 drive enclosures, or up to two D3284 and one D1224 drive enclosures can be daisy-chained with support for up to two hosts attached to the chain.

For topologies with four or more hosts, SAS Y-cables are required to connect the hosts to the drive enclosure. The SAS Y-cable allows two hosts to be connected to one SAS port on the ESM.

The following figures illustrate different host connectivity topologies.

Connectivity topology with one host
Figure 4. Connectivity topology with one host

Connectivity topology with two hosts
Figure 5. Connectivity topology with two hosts

Connectivity topology with three hosts
Figure 6. Connectivity topology with three hosts

The SAS zoning feature of the D3284 specifies how multiple hosts access drives in the enclosures. If SAS zoning is disabled, all attached hosts can access all drives in the enclosures, which is typically used in standalone single-host or clustered multi-host environments, where all cluster nodes need access to all drives. If SAS zoning is enabled, each connected host has exclusive access to a predefined set of drives in the same enclosure, and multiple hosts are isolated from each other.

Configuration notes:

  • Attachment of more than one host to the same enclosure without SAS zoning enabled is supported with HBAs only (RAID controllers are not supported). While all attached hosts are capable of accessing all drives in the enclosures, the clustering software running on the hosts controls which cluster nodes have access to the drives at any given time.
  • With SAS zoning enabled, only standalone enclosures without daisy-chaining can be partitioned for multiple host access.

The supported zone configurations are shown in the following table.

Note: Mode 0 means that zoning is disabled. 

Table 4. D3284 zoning configurations
Zoning
mode
Number
of zones
Maximum
number
of hosts
Number of
drive bays
in one zone
Zone
number
Host
ports
Exp.
ports
Drive bays
Zoning with SAS standard cables
Mode 0 1 2 84 1 A, B C 0-83
Mode 1 2 2 42 1 A C 0-6, 14-20, 28-34, 42-48, 56-62, 70-76
2 B 7-13, 21-27, 35-41, 49-55, 63-69, 77-83
Mode 2 3 3 28 1 A N/A 0-4, 14-18, 28-31, 42-46, 56-60, 70-73
2 B 5-9, 19-22, 32-36, 47-51, 61-64, 74-78
3 C 10-13, 23-27, 37-41, 52-55, 65-69, 79-83
Zoning with SAS Y-cables
Mode 3 3 3 28 1 A.1 C 0-4, 14-18, 28-31, 42-46, 56-60, 70-73
2 A.2 5-9, 19-22, 32-36, 47-51, 61-64, 74-78
3 B.1 10-13, 23-27, 37-41, 52-55, 65-69, 79-83
Mode 4 4 4 21 1 A.1 C 0-3, 14-17, 28-30, 42-45, 56-58, 70-72
2 A.2 4-6, 18-20, 31-34, 46-48, 59-62, 73-76
3 B.1 7-10, 21-24, 35-37, 49-52, 63-65, 77-79
4 B.2 11-13, 25-27, 38-41, 53-55, 66-69, 80-83
Mode 5 6 6 14 1 A.1 N/A 0-2, 14-15, 28-29, 42-44, 56-57, 70-71
2 A.2 3-4, 16-18, 30-31, 45-46, 58-60, 72-73
3 B.1 5-6, 19-20, 32-34, 47-48, 61-62, 74-76
4 B.2 7-9, 21-22, 35-36, 49-51, 63-64, 77-78
5 C.1 10-11, 23-25, 37-38, 52-53, 65-67, 79-80
6 C.2 12-13, 26-27, 39-41, 54-55, 68-69, 81-83

The following table lists ordering information for the SAS cables that are supported with the D3284.

Table 5. SAS cable options
Description Part number Feature code Maximum quantity per one D3284
Connectivity cables - Mini-SAS HD Host Adapter to Expansion
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable 00YL847 AU16 6
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable 00YL848 AU17 6
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable 00YL849 AU18 6
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable 00YL850 AU19 6
External MiniSAS HD 8644/MiniSAS HD 8644 6M Cable 00KH452 AUJY 6
External MiniSAS HD 8644/2xMiniSAS HD 8644 2M Y-Cable 01DC164 AU1A 6
Connectivity cables - Mini-SAS Host Adapter to Expansion
1m (SFF-8644 to SFF-8088) 6Gbps External mini-SAS cable 00YE313 ATC1 6
2m (SFF-8644 to SFF-8088) 6Gbps External mini-SAS cable 00YE314 ATC2 6
6m (SFF-8644 to SFF-8088) 6Gbps External mini-SAS cable 00YE316 ATC4 6
External MiniSAS HD 8644/2xMiniSAS 8088 2M Y-Cable 01CX831 AUF7 6
Connectivity cables - Expansion to Expansion
External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable 00YL847 AU16 2
External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable 00YL848 AU17 2
External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable 00YL849 AU18 2
External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable 00YL850 AU19 2
External MiniSAS HD 8644/MiniSAS HD 8644 6M Cable 00KH452 AUJY 2

Configuration note: The Y-cables and standard cables are mutually exclusive, that is, either Y-cables or standard cables can be used to connect the hosts to the same drive enclosure, but not both types.

Drives

The D3284 drive enclosure supports up to 84x 3.5-inch hot-swap drives. The supported drive types are NL SAS HDDs and SAS SSDs. The following rules apply when selecting the drive configuration:

  • The drives must be installed in rows. Each row contains 14 drive bays, and there are six rows in the enclosure (three rows per drawer).
  • The drives must be installed in a quantity of 14 per row (all drive bays in the row should be populated).
  • Intermixing HDDs and SSDs is supported within the drawer/enclosure and within the first row in the top drawer, but not within other rows.
  • If SSDs and HDDs are intermixed in the first row in the top drawer, up to four SSDs can be installed, and the remaining slots must be populated with HDDs; the total quantity of the SSDs and HDDs must be equal to 14:
    • 1x SSD + 13x HDDs
    • 2x SSD + 12x HDDs
    • 3x SSD + 11x HDDs
    • 4x SSD + 10x HDDs
  • Intermixing HDDs of various sizes within a row is supported.

The following tables list drive options for the D3284 drive enclosures.

Table 6. Drive options
Description Part number Feature code Maximum quantity supported
12 Gbps NL SAS hot-swap HDDs (14-pack)
Lenovo Storage 3.5" 4TB 7.2K NL-SAS HDD (14 pack) 01CX814 AUDS 6
Lenovo Storage 3.5" 6TB 7.2K NL-SAS HDD (14 pack) 01CX816 AUDT 6
Lenovo Storage 3.5" 8TB 7.2K NL-SAS HDD (14 pack) 01CX820 AUDU 6
Lenovo Storage 3.5" 10TB 7.2K NL-SAS HDD (14 pack) 01CX778 AUE4 6
Lenovo Storage 3.5" 12TB 7.2K NL-SAS HDD (14 pack) 4XB7A09919 B106 6
12 Gbps NL SAS hot-swap HDDs (1-pack)
Lenovo Storage 3.5" 4TB 7.2K NL-SAS HDD 01GT910 AUK2 84
Lenovo Storage 3.5" 6TB 7.2K NL-SAS HDD 01GT911 AUK1 84
Lenovo Storage 3.5" 8TB 7.2K NL-SAS HDD  01GT912 AUK0 84
Lenovo Storage 3.5" 10TB 7.2K NL-SAS HDD   01GT913 AUJZ 84
Lenovo Storage 3.5" 12TB 7.2K NL-SAS HDD 4XB7A09920 B107 84
12 Gbps SAS hot-swap SSDs (10 Drive Writes per Day) (1-pack)
Lenovo Storage 400GB 10DWD SAS SSD (2.5" in 3.5" Hybrid Tray 1200.2) 4XB7A09921 AXDY 84
12 Gbps SAS hot-swap SSDs  (3 Drive Writes per Day) (1-pack)
Lenovo Storage 400GB 3DWD SAS SSD (2.5" in 3.5" Hybrid Tray 1200.2) 01CX780 AUE3 84
Lenovo Storage 400GB 3DWD SAS SSD (2.5" in 3.5" Hybrid Tray PM1635a) 4XB7A09922 B105 84
12 Gbps SAS hot-swap SSDs (1 Drive Write per Day) (1-pack)
Lenovo Storage 3.84TB 1DWD SAS SSD (2.5" in 3.5" Hybrid Tray 1200.2) 4XB7A09526 B14A 84
Lenovo Storage 3.84TB 1DWD SAS SSD (2.5" in 3.5" Hybrid Tray PM1633a) 4XB7A09525 B14B 84
Lenovo Storage 7.68TB 1DWD SAS SSD (2.5" in 3.5" Hybrid Tray PM1633a) 4XB7A09524 B149 84
Lenovo Storage 15.36TB 1DWD SAS SSD (2.5" in 3.5" Hybrid Tray PM1633a) 4XB7A08981 B108 84

Power supplies and cables

The D3284 expansion enclosures have two redundant 2214 W (200-240 V AC) hot-swap power supplies. Each power supply has an IEC 320-C19 connector.

The models of the D3284 expansion enclosures that are listed in the Models section ship standard with two 2m, 16A/100-250V, C19 to IEC 320-C20 rack power cables. Other power cable options are also available, and the part numbers and feature codes to order the power cables are listed in the following table (two power cables are required per each D3284).

Table 7. Power cable options
Description Part number Feature code
Rack power cables
2m, 16A/100-250V, C19 to IEC 320-C20 Rack Power Cable None* 6292
2.5m, 16A/100-240V, C19 to IEC 320-C20 Rack Power Cable 39Y7916 6252
Country-specific power cords
4.3m, 16A/208V, C19 to NEMA L6-20P (US) Line Cord 40K9772 6275
4.3m, US/CAN, NEMA L15-30P - (3P+Gnd) to 3X IEC 320 C19 Line Cord 00D7192 A2Y3
4.3m, EMEA/AP, IEC 309 32A (3P+N+Gnd) to 3X IEC 320 C19 Line Cord 00D7193 A2Y4
4.3m, A/NZ, (PDL/Clipsal) 32A (3P+N+Gnd) to 3X IEC 320 C19 Line Cord 00D7194 A2Y5

* Two cables are included with the D3284 models listed in the Models section or can be configured for CTO models.

Physical specifications

The D3284 expansion enclosures have the following dimensions and weight (approximate):

  • Height: 221 mm (8.7 in.)
  • Width: 447 mm (17.6 in.)
  • Depth: 933 mm (36.7 in.)
  • Weight (Maximum): 131 kg (288.8 lb)

Operating environment

The D3284 expansion enclosures are supported in the following environment:

  • Air temperature:
    • Operating: 5 °C to 35 °C (41 °F to 95 °F); maximum temperature decreased by 5 °C above 2134 m (7000 ft)
    • Non-operating: -40 °C to 70 °C (-40 °F to 158 °F)
  • Humidity:
    • Operating: 20% to 80% (non-condensing)
    • Non-operating: 5% to 100% (no precipitation)
  • Maximum altitude:
    • Operating: 3048 m (10,000 ft)
    • Non-operating: 12192 m (40,000 ft)
  • Electrical: 200 to 240 V AC (nominal); 50 Hz to 60 Hz; 7.5 A
  • BTU output: 5664 BTU/hr (1660 W)
  • Noise level: 8.0 bels

Warranty services

The D3284 expansion enclosures have a three-year customer-replaceable unit (CRU) warranty with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Some countries might have different warranty terms and conditions than the standard warranty. This is due to local business practices or laws in the specific country. Local service teams can assist in explaining country-specific terms when needed. Examples of country-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spares parts.

Also available are Lenovo Services warranty upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For information about Lenovo warranty service upgrade offerings that are available in your country or area, refer to the following resources:

In general, the following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • 3, 4, or 5 years of warranty service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select countries)
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select countries)
  • Premier Support

    Premier Support service offers single point of contact for end-to-end problem resolution and collaborative third-party software support with direct access to Lenovo’s most advanced technicians for faster troubleshooting.

  • YourDrive YourData

    Lenovo’s YourDrive YourData service (where applicable) is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo system. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Foundation, Essential, or Advanced Service upgrades and extensions.

  • Basic Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

For service definitions, country-specific details, and service limitations, please refer to the following documents:

Regulatory compliance

The D3284 expansion enclosures conform to the following regulations:

  • BSMI CNS 13438, Class A; CNS 14336 (Taiwan)
  • CCC GB 4943.1, GB 17625.1, GB 9254 Class A (China)
  • CE Mark (European Union)
  • CISPR 22, Class A
  • EAC (Russia)
  • EN55022, Class A
  • EN55024
  • FCC Part 15, Class A (United States)
  • ICES-003/NMB-03, Class A (Canada)
  • IEC/EN60950-1
  • MSIP (Korea)
  • NOM-019 (Mexico)
  • RCM (Australia)
  • Reduction of Hazardous Substances (ROHS)
  • UL/CSA IEC 60950-1
  • VCCI, Class B (Japan)

Interoperability

Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The Lenovo Storage D3284 supports attachment to Lenovo ThinkSystem, System x, and ThinkServer hosts.

For end-to-end storage configuration support, refer to the Lenovo Storage D3284 Interoperability Matrix:
http://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/d3284/6413/documentation

The following sections list adapters, servers, and operating systems supported by Lenovo that can be used with the Lenovo Storage D3284:

Important: Information that is provided in these sections is for order reference purposes only. Not all possible combinations might be supported. End-to-end storage configuration support must be verified through the Lenovo Storage D3284 Interoperability Matrix.

SAS RAID controllers and HBAs

The D3284 expansion enclosures are supported with the RAID adapters and HBAs that are listed in the following table.

Table 8. RAID controllers and HBAs
Description Part number Maximum
quantity of
D3284
per adapter
ThinkSystem HBAs
ThinkSystem 430-8e SAS/SATA 12Gb HBA 7Y37A01090 4
ThinkSystem 430-16e SAS/SATA 12Gb HBA 7Y37A01091 4
System x RAID controllers
ServeRAID M5120 SAS/SATA Controller (6 Gbps SAS) 81Y4478 2
ServeRAID M5225-2GB SAS/SATA Controller (12 Gbps SAS) 00AE938 2
System x HBAs
N2125 SAS/SATA HBA (6 Gbps SAS) 46C9010 2
N2225 SAS/SATA HBA (12 Gbps SAS) 00AE912 4
N2226 SAS/SATA HBA (12 Gbps SAS) 00AE916 4
ThinkServer RAID controllers
ThinkServer 9286CV-8e PCIe 6Gb 8 Port External SAS RAID Adapter by LSI 4XB0F28699 2
ThinkServer 9380-8e PCIe 12Gb 8 port External SAS RAID Adapter by LSI-Avago 4XC0G88845 2
ThinkServer HBAs
ThinkServer 9300-8e PCIe 12Gb 8-port External SAS Adapter by LSI 4XB0F28703 4

The following tables summarize features of supported adapters.

Table 9. RAID controller features and specifications summary
Feature M5120 M5225-2GB 9286CV-8e 9380-8e
Form factor Low profile Low profile Low profile Low profile
SAS controller chip SAS2208 SAS3108 SAS2208 SAS3108
Host interface PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8
Port interface 6 Gb SAS 12 Gb SAS 6 Gb SAS 12 Gb SAS
Number of ports 8 8 8 8
Connector type SFF-8088 x4 SFF-8644 x4 SFF-8088 x4 SFF-8644 x4
Number of connectors 2 2 2 2
Drive interface SAS SAS SAS SAS
Drive type HDD, SSD HDD, SSD HDD, SSD HDD, SSD
Number of devices 240 240 240 240
RAID levels 0/1/10/5/50;
Optional 6/60
(81Y4546)
0/1/10/5/50;
Optional 6/60
(PN 47C8706)
0/1/10/5/50/6/60 0/1/10/5/50/6/60
JBOD mode No No No No
Cache Required:
  • 512 MB no backup
    (81Y4484)
  • 512 MB battery backup
    (81Y4484 + 81Y4508)
  • 512 MB flash backup
    (81Y4487)
  • 1 GB flash backup
    (81Y4559)
  • 2 GB flash backup
    (47C8670)
2 GB flash
backup
(included)
1 GB flash
backup
(included)
1 GB; Flash
backup required
(4XB0G45761)
SSD I/O acceleration
(FastPath)
Optional
(90Y4273)
Optional
(PN 47C8710)
Yes Yes
SSD caching
(CacheCade Pro 2.0)
Optional
(90Y4318)
Optional
(PN 47C8712)
Optional
(4XB0F28702)
None
Table 10. HBA features and specifications summary
Feature 430-8e 430-16e N2125 N2225 N2226 9300-8e
Form factor Low profile Low profile Low profile Low profile Low profile Low profile
SAS controller chip SAS3408 SAS3416 SAS2308 SAS3008 SAS3008 SAS3008
Host interface PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x8
Port interface 12 Gb SAS 12 Gb SAS 6 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 16 8 8 16 8
Connector type SFF-8644 x4 SFF-8644 x4 SFF-8088 x4 SFF-8644 x4 SFF-8644 x4 SFF-8644 x4
Number of connectors 2 4 2 2 4 2
Drive interface SAS SAS SAS SAS SAS SAS
Drive type HDD, SSD HDD, SSD HDD, SSD HDD, SSD HDD, SSD HDD, SSD
Number of devices 2048 4096 1024 1024 1024 1024
RAID levels None None None None None None
JBOD mode Yes Yes Yes Yes Yes Yes
Cache None None None None None None
Cache protection None None None None None None
SSD I/O acceleration
(FastPath)
None None None None None None
SSD caching
(CacheCade Pro 2.0)
None None None None None None

Servers

The D3284 expansion enclosures are supported with Lenovo servers that support the RAID controllers and HBAs listed in the SAS RAID controllers and HBAs section, including the following Lenovo rack-mount servers:

  • ThinkSystem
    • ThinkSystem SR530 Types 7X07 and 7X08
    • ThinkSystem SR550 Types 7X03 and 7X04
    • ThinkSystem SR630 Types 7X01 and 7X02
    • ThinkSystem SR650 Types 7X05 and 7X06
    • ThinkSystem SR850 7X18 and 7X19
    • ThinkSystem SR950 7X11, 7X12, and 7X13
  • System x
    • System x3250 M5 Type 5458
    • System x3550 M5 Type 5463
    • System x3550 M5 Type 8869
    • System x3650 M5 Type 5462
    • System x3650 M5 Type 8871
    • System x3750 M4 Type 8753
    • System x3850 X6 Type 6241 (E7 v2, E7 v3, and E7 v4) 
    • System x3950 X6 Type 6241 (E7 v2, E7 v3, and E7 v4)  
  • ThinkServer
    • ThinkServer RS160 (E3-1200 v5, E3-1200 v6, Core i3, Pentium G, and Celeron G Series)
    • ThinkServer RD350 (E5-2600 v3 and E5-2600 v4)
    • ThinkServer RD450 (E5-2600 v3 and E5-2600 v4)
    • ThinkServer RD550 (E5-2600 v3 and E5-2600 v4)
    • ThinkServer RD650 (E5-2600 v3 and E5-2600 v4)

For RAID adapters and HBAs support details for a particular server, refer to a Lenovo Press product guide for the server, found at: http://lenovopress.com

Operating systems

The D3284 expansion enclosures support the following operating systems:

  • Microsoft:
    • Microsoft Windows Server 2016 Storage Spaces Direct (S2D)
    • Microsoft Windows Server 2016 (Hyper-V)
    • Microsoft Windows Server 2012 R2
    • Microsoft Windows Server 2012 R2 (Hyper-V)
  • Red Hat:
    • Red Hat Enterprise Linux 7.3
    • Red Hat Enterprise Linux 7.2
    • Red Hat Enterprise Linux 7.1
    • Red Hat Enterprise Linux 6.8 Server x64 Edition
    • Red Hat Enterprise Linux 6.7 Server x64 Edition
  • SUSE:
    • SUSE Linux Enterprise Server 12 SP2
    • SUSE Linux Enterprise Server 12 SP1
    • SUSE Linux Enterprise Server 12
    • SUSE Linux Enterprise Server 11 SP4 for AMD64/EM64T
  • VMware:
    • VMware vSphere 6.0 (ESXi) Update 3
    • VMware vSphere 6.0 (ESXi) Update 2
    • VMware vSphere 6.0 (ESXi) Update 1
    • VMware vSphere 6.0 (ESXi)
    • VMware vSphere 5.5 (ESXi) Update 3

For information about operating system compatibility with Lenovo servers, refer to the Operating System Interoperability Guide: http://lenovopress.com/osig

Rack cabinets

The following table lists the rack cabinets that are offered by Lenovo that can be used in D3284 storage expansion solutions.

Table 11. Rack cabinets
Description Part number
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072RX
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 93072PX
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) 93074RX
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) 93634PX
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) 93634EX
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) 93604PX
42U 1200mm Deep Static Rack (6 sidewall compartments) 93614PX
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) 93084PX
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) 93084EX

For more information, see the list of Product Guides in the Rack Cabinets category:
http://lenovopress.com/servers/options/racks

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in D3284 storage expansion solutions.

Table 12. Power distribution units
Description Part number
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord 00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord 00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord 00YJ780
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord 00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord 00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) 46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord 46M4003
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord) 71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord 71763NU
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord) 39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord 39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord 39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord 39Y8935
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P) 40K9614
DPI 32a Line Cord (IEC 309 P+N+G) 40K9612
DPI 32a Line Cord (IEC 309 3P+N+G) 40K9611
DPI 60a Cord (IEC 309 2P+G) 40K9615
DPI 63a Cord (IEC 309 P+N+G) 40K9613
DPI Australian/NZ 3112 Line Cord (32A) 40K9617
DPI Korean 8305 Line Cord (30A) 40K9618

For more information, see the list of Product Guides in the PDU category:
http://lenovopress.com/servers/options/pdu

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in D3284 storage expansion solutions.

Table 13. Uninterruptible power supply units
Description Part number
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55942KX
RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x IEC 320 C19 16A outlets) 55943KX
RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55945KX
RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x IEC 320 C19 16A outlets) 55946KX
RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55948KX
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55948PX
RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) 55949KX
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) 55949PX

For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category:
http://lenovopress.com/servers/options/ups

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovofs.com

Related product families

Product families related to this document are the following: