Abstract

The Intel P3700 NVMe Enterprise Performance Flash Adapters are a new family of PCIe Flash Storage Adapters from Intel. This product guide introduces the adapters and describes their features and specifications, and provides compatibility information. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the adapters and consider their use in IT solutions.

Introduction

The Intel P3700 NVMe Enterprise Performance Flash Adapters are a new family of PCIe Flash Storage Adapters that provides high performance data transfers from storage, at rates significantly faster than SAS or SATA-based SSDs.

The Intel P3700 NVMe Enterprise Performance Flash Adapter devices are based on Intel-developed controller, firmware, and leading manufacturing process NAND flash memory. Rigorous qualification and compatibility testing by Lenovo ensures a highly reliable flash adapter. By combining Flash NAND management techniques and NAND silicon enhancements, High Endurance Technology (HET) enables the P3700 Series to achieve up to 17 drive writes per day over a 5 year drive life.

The adapter is shown in the following figure.

P3700 NVMe Enterprise Performance Flash Adapter

Figure 1. Intel P3700 NVMe Enterprise Performance Flash Adapter

Did You Know?

NVMe (Non-Volatile Memory Express) is a technology that overcomes SAS/SATA SSD performance limitations by optimizing hardware and software to take full advantage of flash technology. Intel Xeon processors efficiently transfer data in fewer clock cycles with the NVMe optimized software stack compared to the legacy Advance Host Controller Interface (AHCI) stack, thereby reducing latency and overhead. These adapters connect directly to the processor via the PCIe bus, further reducing latency and TCO.

Part number information

Withdrawn: All adapters are withdrawn from marketing.

The following table shows the part numbers for adapters supported on System x servers.

Table 1. Ordering part numbers - System x
Part number Feature Description
01GT711 AVPY Intel P3700 800GB NVMe Enterprise Performance Flash Adapter
00YA812 AT7L Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter
00YA815 AT7M Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter

The following table shows the part numbers for adapters supported on ThinkServer systems.

Table 2. Ordering part numbers - ThinkServer
Part number Description
4XB0K12391 ThinkServer Intel P3700 800GB NVMe Enterprise Performance Flash Adapter

The part numbers for the adapters include the following items:

  • One adapter with full-height (3U) PCIe bracket attached
  • Separate low-profile (2U) PCIe bracket
  • Documentation

Features

The Intel P3700 NVMe Enterprise Performance Flash Adapters are PCIe 3.0 storage devices in a standard half-high half-length PCIe form factor. The adapters use the the new Non-Volatile Memory express (NVMe) high-performance controller interface which delivers leading performance, low latency, and quality of service. The adapters offer capacities up to 2.0 TB and provide world-class reliability and endurance.

The P3700 adapters deliver excellent sequential read performance of up to 2.8 GB/s and sequential write speeds of up to 2.0 GB/s. The adapters can also deliver very high random read IOPS of 460K and random write IPS of 175K for 4 KB operations. Taking advantage of the direct path from the adapter to the processor, the P3700 adapters have low latency of less than 20 µs for sequential access.

The P3700 adapters also include High Endurance Technology (HET) which combines NAND silicon enhancements and SSD NAND management techniques to extend SSD write endurance up to 17 drive writes per day (DWPD) for 5 years.

Key features:

  • Consistently high IOPS and throughput
  • Sustained low latency
  • High Endurance Technology (HET)
  • Uncorrectable bit error rate (UBER): 1 sector per 1017 bits read
  • Mean time before failure (MTBF): 2 million hours
  • Variable sector size (512, 520, 528, 4096, 4104, 4160 and 4224 byte support)
  • Enhanced power-loss data protection
  • Power loss protection capacitor self-test with S.M.A.R.T alerting
  • Out-of-band management via SMBus interface
  • Thermal throttling and management

Technical specifications

The following table lists the technical specifications for the Intel P3700 NVMe Enterprise Performance Flash Adapters.

Table 3. Technical specifications
Specification 800 GB adapter 1.6 TB adapter 2.0 TB adapter
Part number 01GT711
4XC0G88861
00YA812 00YA815
Interface PCIe 3.0 x4 PCIe 3.0 x4 PCIe 3.0 x4
Form factor Half height, half length Half height, half length Half height, half length
Capacity 800 GB 1.6 TB 2.0 TB
Endurance 14.6 PB TBW
10 DWPD
43.8 PB TBW
15 DWPD
62.05 PB TBW
17 DWPD
Random read IOPS (4 KB blocks) 460,000 (90% consistent) 450,000 (90% consistent) 450,000 (90% consistent)
Random write IOPS (4 KB blocks) 90,000 (90% consistent) 150,000 (90% consistent) 175,000 (90% consistent)
Sequential read throughput 2.8 GBps 2.8 GBps 2.8 GBps
Sequential write throughput 1.9 GBps 1.9 GBps 1.9 GBps
Read access latency sequential* 20 µs 20 µs 20 µs
Read access latency random* 115 µs 115 µs 115 µs
Write access latency sequential* 20 µs 20 µs 20 µs
Write access latency random* 25 µs 25 µs 25 µs
Power requirements 25 W 25 W 25 W

* Latency measured using 4 KB transfer size with queue depth = 1 on a sequential workload using Windows Server 2012 R2 drivers. Power mode set at 25W.

Enterprise Performance solid-state devices have read and write IOPS and throughput performance that are comparable to Enterprise Mainstream devices, but the key difference between them is their endurance (or lifetime); that is, how long they can perform write operations because solid-state devices have a finite number of program/erase (P/E) cycles.

Enterprise Performance PCIe Flash Adapters have better endurance and higher IOPS/GB ratio but also a higher cost/IOPS ratio compared to Enterprise Mainstream PCIe Flash adapters. Because of this fact, the Enterprise Performance PCIe Flash Adapters are targeted for mixed read- and write-intensive workloads, and the Enterprise Mainstream PCIe Flash Adapters are targeted for read-intensive workloads. Solid-state device write endurance often is measured by the number of P/E cycles that the drive incurs over its lifetime, which is listed as the total bytes of written (TBW) data in the device specification.

The TBW value that is assigned to a solid-state device is the total bytes of written data (based on the number of P/E cycles) that a device can be guaranteed to complete (the percentage of remaining P/E cycles is equal to the percentage of remaining TBW). The Lenovo warranty for the solid-state storage is limited to devices that have not reached the maximum guaranteed number of program/erase cycles. Solid-state storage that reaches this limit might fail to operate according to its specifications. Because of such behavior by solid-state devices, careful planning must be done to use solid-state storage in the application environments to ensure that the TBW of the device is not exceeded before the end of the required life expectancy.

Server support - System x

The following tables list the server compatibility information for the adapters on System x servers.

Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors

Table 4. Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Part
number
Description
x3250 M6 (3943)
x3250 M6 (3633)
x3550 M5 (8869)
x3650 M5 (8871)
x3850 X6/x3950 X6 (6241, E7 v4)
nx360 M5 (5465, E5-2600 v4)
sd350 (5493)
01GT711 Intel P3700 800GB NVMe Enterprise Performance Flash Adapter N N Y Y Y N N
00YA812 Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter N N Y Y Y N N
00YA815 Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter N N Y Y Y N N

Support for System x and dense servers with Intel Xeon v3 processors

Table 5. Support for System x servers with Intel Xeon v3 processors
Part
number
Description
x3100 M5 (5457)
x3250 M5 (5458)
x3500 M5 (5464)
x3550 M5 (5463)
x3650 M5 (5462)
x3850 X6/x3950 X6 (6241, E7 v3)
nx360 M5 (5465)
01GT711 Intel P3700 800GB NVMe Enterprise Performance Flash Adapter N N N N N N N
00YA812 Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter N N N Y Y Y N
00YA815 Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter N N N Y Y Y N

Support for System x servers with Intel Xeon v2 processors

Table 6. Support for System x servers with Intel Xeon v2 processors
Part
number
Description
x3500 M4 (7383, E5-2600 v2)
x3530 M4 (7160, E5-2400 v2)
x3550 M4 (7914, E5-2600 v2)
x3630 M4 (7158, E5-2400 v2)
x3650 M4 (7915, E5-2600 v2)
x3650 M4 BD (5466)
x3650 M4 HD (5460)
x3750 M4 (8752)
x3750 M4 (8753)
x3850 X6/x3950 X6 (3837)
x3850 X6/x3950 X6 (6241, E7 v2)
dx360 M4 (E5-2600 v2)
nx360 M4 (5455)
01GT711 Intel P3700 800GB NVMe Enterprise Performance Flash Adapter N N N N N N N N N N N N N
00YA812 Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter N N N N N N N N N N Y N N
00YA815 Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter N N N N N N N N N N Y N N

Support for Flex System compute nodes

The adapters are supported in the following Flex System compute nodes when installed in an attached PCIe Expansion Node.

Table 7. Support for Flex System servers
Part
number
Description
x220 (7906)
x222 (7916)
x240 (8737, E5-2600)
x240 (8737, E5-2600 v2)
x240 (7162)
x240 M5 (9532, v3 & v4)
x440 (7917)
x440 (7167)
x880/x480/x280 X6 (7903)
x280/x480/x880 X6 (7196)
01GT711 Intel P3700 800GB NVMe Enterprise Performance Flash Adapter N N N N N N N N N N
00YA812 Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter N N N N N Y† N N N N
00YA815 Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter N N N N N Y† N N N N

† Supported when installed in an attached PCIe Expansion Node 

Server support - ThinkServer

The following tables list the server compatibility information for the adapters on ThinkServer systems.

Support for sd350: The ThinkServer sd350 is listed in Table 4.

Support for ThinkServer Generation 5 servers with E5 v4 and E3 v5/v6 processors

Table 8. Support for ThinkServer Generation 5 servers with E5 v4 and E3 v5/v6 processors
Part number Description
TS150
TS450
TS460
RS160
TD350
RD350 (70Qx)
RD450 (70Qx)
RD550 (70Rx/70Sx)
RD650 (70Rx)
4XB0K12391 Intel P3700 800GB NVMe Enterprise Performance Flash Adapter N N N N N N N Y Y

Support for ThinkServer Generation 5 servers with E5 v3 and E3 v3 processors

Table 9. Support for ThinkServer Generation 5 servers with E5 v3  and E3 v3 processors
Part number Description
TS140
TS440
RS140
TD350
RD350 (70Dx)
RD450 (70Dx)
RD550 (70Cx)
RD650 (70Dx)
4XB0K12391 Intel P3700 800GB NVMe Enterprise Performance Flash Adapter N N N N N N N N

Operating system support

Table 10. Operating system support for Intel P3700 800GB NVMe Enterprise Performance Flash Adapter, 01GT711
Operating systems
x3850/3950 X6 (6241, E7 v4)
x3550 M5 (8869)
x3650 M5 (8871)
x240 M5 (9532)
Microsoft Windows Server 2012 R2 Y N Y Y
Microsoft Windows Server 2016 Y Y Y Y
Microsoft Windows Server 2019 Y Y Y Y
Microsoft Windows Server version 1709 Y Y Y Y
Microsoft Windows Server version 1803 N Y Y N
Red Hat Enterprise Linux 6 Server x64 Edition Y Y Y Y
Red Hat Enterprise Linux 7 Y Y Y Y
Red Hat Enterprise Linux 8.0 Y N N N
SUSE Linux Enterprise Server 11 for AMD64/EM64T Y Y Y Y
SUSE Linux Enterprise Server 12 Y Y Y Y
SUSE Linux Enterprise Server 15 Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.0 Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.5 Y Y Y Y
VMware vSphere Hypervisor (ESXi) 6.7 Y Y Y Y
Table 11. Operating system support for P3700 1.6TB Enterprise Performance NVMe Flash Adapter, 00YA812
Operating systems
x3850/3950 X6 (6241, E7 v3)
x3850/3950 X6 (6241, E7 v4)
x3550 M5 (5463)
x3550 M5 (8869)
x3650 M5 (5462)
x3650 M5 (8871)
x240 M5 (9532)
Microsoft Windows Server 2008 R2 Y N Y Y Y N N
Microsoft Windows Server 2012 Y Y Y N Y N Y 1
Microsoft Windows Server 2012 R2 Y Y Y Y Y Y Y 1
Microsoft Windows Server 2016 Y Y Y N Y Y Y
Microsoft Windows Server version 1709 Y Y Y Y Y Y Y
Red Hat Enterprise Linux 6 Server x64 Edition Y Y Y N Y N Y 1
Red Hat Enterprise Linux 7 Y Y Y Y Y Y Y 1
SUSE Linux Enterprise Server 11 for AMD64/EM64T Y Y Y N Y N Y 1
SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T Y Y Y N Y N Y 1
SUSE Linux Enterprise Server 12 Y Y Y Y Y Y Y 1
SUSE Linux Enterprise Server 12 with Xen Y Y Y Y Y Y Y 1
VMware vSphere Hypervisor (ESXi) 5.5 Y N Y N Y N Y 1, 2
VMware vSphere Hypervisor (ESXi) 6.0 Y Y Y Y Y Y Y 1

1 Support Haswell only

2 [VMware 5.5 up 3 does not support NVMe as boot drive. Tested as data drive.]

Table 12. Operating system support for P3700 2TB Enterprise Performance NVMe Flash Adapter, 00YA815
Operating systems
x3850/3950 X6 (6241, E7 v3)
x3850/3950 X6 (6241, E7 v4)
x3550 M5 (5463)
x3550 M5 (8869)
x3650 M5 (5462)
x3650 M5 (8871)
x240 M5 (9532)
Microsoft Windows Server 2008 R2 Y N Y Y Y N N
Microsoft Windows Server 2012 Y Y Y N Y N Y 1
Microsoft Windows Server 2012 R2 Y Y Y Y Y Y Y 1
Microsoft Windows Server 2016 Y Y Y N Y Y Y
Microsoft Windows Server version 1709 Y Y Y Y Y Y Y
Red Hat Enterprise Linux 6 Server x64 Edition Y Y Y N Y N Y 1
Red Hat Enterprise Linux 7 Y Y Y Y Y Y Y 1
SUSE Linux Enterprise Server 11 for AMD64/EM64T Y Y Y N Y N Y 1
SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T Y Y Y N Y N Y 1
SUSE Linux Enterprise Server 12 Y Y Y Y Y Y Y 1
SUSE Linux Enterprise Server 12 with Xen Y Y Y Y Y Y Y 1
VMware vSphere Hypervisor (ESXi) 5.5 Y N Y N Y N Y 1, 2
VMware vSphere Hypervisor (ESXi) 6.0 Y Y Y Y Y Y Y 1

1 Support Haswell only

2 [VMware 5.5 up 3 does not support NVMe as boot drive. Tested as data drive.]

Warranty

The Intel P3700 NVMe Enterprise Performance Flash Adapters carry a 1-year, customer-replaceable unit (CRU) limited warranty. When installed in a supported Lenovo server, these adapters assume the system’s base warranty and any warranty upgrade.

Physical specifications

The Intel P3700 NVMe Enterprise Performance Flash Adapters have the following physical specifications:

Dimensions and weight (approximate):

  • Width: 19 mm (0.7 in.)
  • Height: 69 mm (2.7 in.)
  • Depth: 167 mm (6.6 in.)
  • Weight: 195 g (0.43 lb)

Shipping dimensions (approximate):

  • Height: 27 mm (1.1 in.)
  • Width: 206 mm (8.1 in.)
  • Depth: 140 mm (5.5 in.)

Operating environment

The Intel P3700 NVMe Enterprise Performance Flash Adapters are supported in the following environment:

  • Temperature (operational): 0 - 55 °C (32 - 131 °F) at 0 - 3,048 m (0 - 10,000 ft)
  • Relative humidity: 5 - 95% (non-condensing)
  • Maximum altitude (operational): 3,048 m (10,000 ft)
  • Shock: 50 G Trapezoidal, 170 in/s
  • Vibration: 2.17 GRMS (5-700 Hz)

Agency approvals

The Intel P3700 NVMe Enterprise Performance Flash Adapters conform to the following regulations:

  • FCC Title 47, Part 15 Subpart B, Class B
  • CAN ICES-3 (B) NMB-3 (B)  
  • EN 55022: 2010
  • EN 61000-3-2: 2006 plus A1:2009 and A2:2009
  • EN 61000-3-3: 2008
  • EN 55024: 2010
  • VCCI V-3/2013.04 Class B
  • ANSI C63.4: 2009 Class B
  • BSMI CNS 13438: 2006 Class B
  • AS/NZS CISPR 22
  • KCC MSIP-REM-CPU-SSDPIA
  • EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011
  • DIRECTIVE 2011/65/EU

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Flex System
ServerProven®
System x®
ThinkServer®

The following terms are trademarks of other companies:

Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.