Lenovo ThinkSystem SD530 Server (Xeon SP Gen 1)

Product Guide (withdrawn product)

Home
Top

Abstract

The Lenovo ThinkSystem SD530 is an ultradense and economical two-socket server in a 0.5U rack form factor. With four SD530 server nodes installed in the ThinkSystem D2 enclosure, and the ability to cable and manage up to four D2 enclosures as one asset, you have an ideal high-density 2U four-node (2U4N) platform for enterprise and cloud workloads.

This product guide provides essential presales information to understand the SD530 node and D2 enclosure, their key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the SD530 and consider its use in IT solutions.

Withdrawn: The ThinkSystem SD530 with 1st Generation Intel Xeon Scalable processors is now withdrawn from marketing. For the SD530 with 2nd Generation processors, see the the following product guide:

Change History

Changes in the February 2, 2021 update:

  • The ThinkSystem SD530 with 1st Generation Intel Xeon Scalable processors is now withdrawn from marketing.

Walkthrough Video with David Watts and Paul Scaini

Introduction

The Lenovo ThinkSystem SD530 is an ultradense and economical two-socket server in a 0.5U rack form factor. With four SD530 servers installed in either the ThinkSystem D2 Enclosure or ThinkSystem Modular Enclosure, you have an ideal high-density 2U four-node (2U4N) platform for enterprise and cloud workloads.

2U4N systems have gained popularity in a variety of data centers, from large enterprises to service providers, because their small footprint and inherent density make them ideal for building solution-based appliances at a low cost. The combination of the Lenovo ThinkSystem SD530 and D2 Enclosure is engineered to deliver these types of solutions.

Suggested use: Cloud, MSP, CSP, HPC, hyperconverged solutions, branch office or remote office needs

The following figure shows four ThinkSystem SD530 servers installed in a D2 Enclosure.

Four ThinkSystem SD530 servers installed in a D2 Enclosure
Figure 1. Four ThinkSystem SD530 servers installed in a D2 Enclosure

Did you know?

The SD530 combines the efficiency and density of blades with the value and simplicity of rack-based servers. It is designed to run the highest-core-count Xeon Platinum processors, to power through your most demanding HPC/technical computing/AI workloads.

The SD530 also supports two high-performance GPUs with the addition of the GPU Tray. The server supports a wide variety of NVIDIA GPUs.

Key features

The ThinkSystem SD530 dense offering fits four hot-pluggable SD530 servers into a ThinkSystem D2 Enclosure or ThinkSystem Modular Enclosure. The enclosures each take up only 2U (0.5U per server) and include room for plenty of internal storage. The overall design makes the solution extremely affordable, with a low total cost of ownership (TCO).

Scalability and performance

The SD530 server and the enclosures offer numerous features to boost performance, improve scalability, and reduce costs:

  • Up to four nodes in a single 2U enclosure, each with two processors from the Intel Xeon processor Scalable family, up to 16 DIMMs, 6 drive bays, and two PCIe slots. It is a highly dense, scalable, and price-optimized offering.
  • Supports a wide selection of processors from the Intel Xeon processor Scalable family - designed to operate with the cost-effective Bronze processors up to the highest-core-count Xeon Platinum processors.
  • Supports processors with up to 28 cores, core speeds up to 3.6 GHz, and TDP ratings up to 165W.
  • Two processors in each server, up to 56 cores total, and 112 threads maximize the concurrent execution of multithreaded applications. With four nodes in the enclosure, a total of 224 cores are available in only 2U of rack space.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Advanced Vector Extensions 512 (AVX-512) enable acceleration of enterprise-class workloads, including databases, and enterprise resource planning.
  • Each processor has six memory channels with memory speeds of up to 2666 MHz to maximize system performance.
  • Supports up to 16 DIMMs to maximize memory capacity, supporting 1 TB using 16x 64 GB LRDIMMs or 1.5 TB using 12x 128 GB 3DS RDIMMs.
  • Supports up to two GPUs with the addition of a 1U GPU Tray, providing increased processing power.
  • The 12 Gbps SAS internal storage connectivity doubles the data transfer rate of 6 Gb SAS solutions, to maximize performance of storage-intensive applications.
  • Each SD530 server supports up to six 2.5-inch hot-swap drives. Two drive bays can be configured to support NVMe drives to maximize I/O performance in terms of throughput, bandwidth, and latency.
  • With 7.68 TB 2.5-inch SAS hot-swap SSDs, each SD530 supports up to 46 TB of internal storage.
  • Supports a new Lenovo patented-design M.2 adapter for convenient operating system boot functions. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for boot drive performance and reliability.
  • The use of solid-state drives (SSDs) instead of, or along with, traditional hard disk drives (HDDs) can improve I/O performance. An SSD can support up to 100 times more I/O read operations per second (IOPS) than a typical HDD.
  • The server has two optional 10 Gb Ethernet ports, either 10GBASE-T or SFP+, routed from the embedded X722 controller to the optional 8-port EIOM module at the rear of the enclosure.
  • One PCIe 3.0 x16 or two PCIe 3.0 x8 slots for added I/O flexibility.
  • PCI Express 3.0 I/O expansion capabilities improve the theoretical maximum bandwidth by 60% compared with the previous generation of PCI Express 2.0.

Manageability and security

Powerful systems management features simplify local and remote management of the SD530:

  • The server includes an XClarity Controller (XCC) to monitor server availability. Optional upgrade to XCC Advanced to provide remote control (keyboard video mouse) functions. Optional upgrade to XCC Enterprise enables the additional support for the mounting of remote media files (ISO and IMG image files), boot capture, and power capping.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure only a digitally signed operating system can be used. Supported with HDDs and SSDs as well as M.2 drives in the M.2 Adapter.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.
  • With the SMM management module installed in the enclosure, only one Ethernet connection is needed to provide remote systems management functions for all four SD530 servers and the enclosure.
  • The enclosure also supports the Dual Ethernet Port SMM management module with allows a single Ethernet connection to be daisy chained across 7 enclosures and 28 servers, thereby significantly reducing the number of Ethernet switch ports needed to manage an entire rack of SD530 servers and enclosures.

Energy efficiency

The SD530 and the enclosures offer the following energy efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to a green environment:

  • ASHRAE A4 compliance for certain configurations to enable operation in 45°C datacenters
  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum certifications. Energy Star 2.1 certified.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
  • Low-voltage 1.2 V DDR4 memory DIMMs use up to 20% less energy than 1.35 V DDR3 DIMMs.
  • SSDs use as much as 80% less power than 2.5-inch HDDs.
  • Optional Lenovo XClarity Energy Manager provide advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.
  • The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system.

Availability and serviceability

The SD530 server and the enclosures provide many features to simplify serviceability and increase system uptime:

  • The server offers Single Device Data Correction (SDDC, also known as Chipkill), Adaptive Double-Device Data Correction (ADDDC, also known as Redundant Bit Steering or RBS), memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • The server offers hot-swap drives, supporting RAID redundancy for data protection and greater system uptime.
  • The Dual M.2 Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
  • The D2 Enclosure and Modular Enclosure both support two hot-swap power supplies, which form a redundant pair to provide availability for business-critical applications.
  • Toolless access to upgrades and serviceable parts, such as fans, adapters, CPUs, and memory.
  • Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. Alerts can be surfaced through the XClarity Controller (XCC) to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • SSDs offer significantly better reliability than traditional mechanical HDDs for greater uptime.
  • The built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager supports diagnostics and can save service data to a USB key drive or remote CIFS share folder for troubleshooting and reduce service time.
  • Auto restart in the event of a momentary loss of AC power (based on power policy setting in the XClarity Controller service processor)
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions (requires the optional KVM Breakout Module).
  • Three-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Components and connectors

The following figure shows the front of the D2 Enclosure. The front view shows the four SD530 nodes, each with 6 drive bays.

Front view of the ThinkSystem D2 enclosure
Figure 2. Front view of the ThinkSystem D2 Enclosure

The following figure shows the rear of the D2 Enclosure.

Rear view of the ThinkSystem D2 Enclosure
Figure 3. Rear view of the ThinkSystem D2 Enclosure

The following figure shows the I/O shuttle removed from the rear of the D2 Enclosure. The fans are hot-swap and are accessible from a removable cover on the top of the enclosure.

I/O Shuttle
Figure 4. I/O Shuttle in the ThinkSystem D2 Enclosure

The following figure shows the front of the SD530 server.

Front view of the SD530
Figure 5. Front view of the SD530 compute node

The following figure shows the internals of the SD530 server identifying key components.

Internal view of the SD530 compute node
Figure 6. Internal view of the SD530 compute node

The SD530 also supports the addition of a GPU Tray which adds support for two double-wide GPUs, as shown in the following figure.

SD530 with attached GPU Tray
Figure 7. SD530 with attached GPU Tray

Standard specifications - SD530 server

The following table lists the standard specifications of the ThinkSystem SD530.

Table 1. Standard specifications - ThinkSystem SD530
Components Specification
Machine type 7X21
Form factor Half-wide, 1U compute node. Optional GPU Tray adds 1U.
Supported chassis ThinkSystem D2 Enclosure, 2U high; up to 4 servers per chassis.
ThinkSystem Modular Enclosure, 2U high; up to 4 servers per chassis.
Processor One or two Intel Xeon Processor Scalable Family processors, either Bronze, Silver, Gold or Platinum level processors (formerly codename "Skylake"). Supports processors with core counts up to 28 cores, core speeds up to 3.6 GHz, and TDP ratings up to 205W. Two Intel Ultra Path Interconnect (UPI) links at up to 10.4 GTps each.
Chipset Intel C624 "Lewisburg" chipset
Memory

Configurations with some processors: Up to 16 DIMM sockets (8 DIMMs per processor)
Other configurations: Up to 12 DIMM sockets (6 DIMMs per processor)

Support Lenovo TruDDR4 DIMMs at up to 2666 MHz. RDIMMs, LRDIMMs and 3DS RDIMMs are supported, but memory types cannot be mixed.

Memory maximums

With 16 DIMMs:

  • RDIMMs: Up to 512 GB with 16x 32 GB RDIMMs and two processors
  • LRDIMMs: Up to 1024 GB with 16x 64 GB LRDIMMs and two processors

12 DIMMs:

  • RDIMMs: Up to 384 GB with 12x 32 GB RDIMMs and two processors
  • LRDIMMs: Up to 768 GB with 12x 64 GB LRDIMMs and two processors
  • 3DS RDIMMs: Up to 1.5 TB with 12x 128 GB 3DS RDIMMs and two processors
Memory protection ECC, SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs, requires Intel Xeon Gold or Platinum processors), memory mirroring, and memory sparing.
Storage bays Up to six 2.5-inch hot-swap drive bays. Depending on the drive backplane selected, the supported drives can be SAS, SATA or NVMe drives. Up to four NVMe drives can be installed with a suitable drive backplane. Also supports one or two M.2 drives installed internally to each node. Other configurations exist including the substitution of a KVM Module in one drive bay for keyboard, video and mouse support. See the Internal storage section for details.
Maximum internal storage
  • 92.16TB using 6x 15.36TB 2.5-inch SAS SSDs
  • 30.72TB using 4x 7.68TB 2.5-inch NVMe SSDs
  • 14.4TB using 6x 2.4TB 2.5-inch HDDs
Storage controller Onboard 6 Gb SATA using embedded Intel RSTe software RAID, supporting RAID 0, 1, 10, 5, 50. Optional 12 Gb SAS/SATA RAID using SAS3408-based cacheless RAID controller, supporting RAID 0, 1, 10, 5. Optional 12 Gb SAS/SATA HBA.
Optical drive bays No internal bays; use an external USB drive.
Tape drive bays No internal bays. Use an external USB drive.
Network interfaces

Two 10 Gb interfaces, either 10GBASE-T ports (RJ-45) or SFP+ ports, routed through the Ethernet I/O Module at the rear of the enclosure. Networking ports are based on the Intel Ethernet Connection X722 in the chipset of the SD530 node.

PCI Expansion slots

One or two PCIe 3.0 slots:

  • One PCIe 3.0 x16 low-profile slot, or
  • Two PCIe 3.0 x8 low-profile slots

Additional slots with the optional GPU Tray:

  • Two PCIe 3.0 x16 full-length double-width slots
Ports

Front: Optional KVM Breakout Module providing one USB 3.0 port, one micro USB port for XClarity Controller connectivity, and a KVM connector port for a breakout cable that provides one VGA port, two USB 2.0 ports and one DB9 serial port for local connectivity.

Additional ports provided by the enclosure as described in the Enclosure specifications section.

Cooling Supplied by the D2 Enclosure.
Power supply Supplied by the D2 Enclosure.
Hot-swap parts HDDs and SSDs
Systems management

Operator panel with system error LED and ID and power controls. XClarity Controller embedded management, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. Optional XClarity Controller Advanced to enable remote control functions.

System Management Module (SMM) in the D2 Enclosure provides additional systems management functions.

Video G200 graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Security Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 1.2 or TPM 2.0. In China only, optional Trusted Cryptographic Module (TCM).
Operating systems supported Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics.
Limited warranty Three-year customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Temperature Up to ASHRAE Class A4: 5°C to 45°C (41°F to 113°F)
Dimensions Height: 41 mm (1.7 inches), depth: 562 mm (22.2 inches), width: 222 mm (8.8 inches)
Weight Minimum weight: 3.5 kg (7.8 lb), maximum weight: 7.5 kg (16.6 lb)

Standard specifications - Enclosure

The SD530 servers are supported in both the ThinkSystem D2 Enclosure and ThinkSystem Modular Enclosure. The following table lists the standard specifications of the enclosures.

Tip: The only difference between the D2 Enclosure and the Modular Enclosure is that the D2 Enclosure has a single-port SMM management module and the Modular Enclosure has a dual-port SMM management module.

Table 2. Standard specifications: D2 Enclosure and Modular Enclosure
Components Specification
Machine type 7X20: D2 Enclosure (ships with single port SMM)
7X22: Modular Enclosure (ships with dual port SMM)
Form factor 2U rack-mounted chassis.
Server support Up to 4 servers per chassis.
Servers per 42U rack Up to 84 servers in 21 enclosures
System Management Module

D2 Enclosure: Single port SMM is standard, supports Dual Port SMM as a field upgrade
Modular Enclosure: Dual Port SMM is standard

The hot-swappable System Management Module (SMM) is the management device for the enclosure. Provides integrated systems management functions and controls the power and cooling features of the enclosure. Provides remote browser and CLI-based user interfaces for remote access via the dedicated Gigabit Ethernet port. Remote access is to both the management functions of the enclosure as well as the XClarity Controller (XCC) in each server.

Supports the SMM with one Ethernet port (D2 Enclosure) or the Dual Port SMM with two Ethernet ports (Modular Enclosure, or the D2 Enclosure with the Dual Port SMM installed). The Dual Port SMM allows a single incoming Ethernet connection to be daisy chained across 7 enclosures and 28 servers, thereby significantly reducing the number of Ethernet switch ports needed to manage an entire rack of SD530 servers and enclosures.

Ethernet I/O Module 8-port Ethernet I/O Module (EIOM) routes two 10 GbE connections to each of the four servers.
Controls and LEDs SMM has four LEDs: system error, identification, status, and system power. Each power supply has AC, DC and error LEDs
Power supplies Two hot-swap power supplies either 1100 W, 1600 W, or 2000 W functioning as a redundant pair. Power supplies must be identical. Power supplies require a 200-240 V ac, 50 or 60 Hz supply, although the 1100 W also supports 100-127V ac 50 or 60 Hz. Power supplies are installed at the rear of the chassis. 80 PLUS Platinum certified. Built-in overload and surge protection.
Cooling Five hot-swap system fans, accessible via removable panel in the top cover of the enclosure.
Hot-swap parts Power supplies, fans, System Management Module
Power consumption Input kilovolt-amperes (kVA): minimum: 0.153 kVA,  maximum: 2.61 kVA
Limited warranty Three-year customer-replaceable unit and onsite limited warranty with 9x5/NBD coverage.
Dimensions 2U chassis. Height: 87 mm (3.5 inches), depth: 892 mm (35.1 inches), width: 488 mm (19.3 inches)
Weight Minimum configuration (with one minimally configured node): 22.4 kg (49.4 lbs)
Maximum configuration (with four fully configured nodes): 55.0 kg (121.2 lbs)

SD530 models

ThinkSystem SD530 models can be configured by using the Lenovo Data Center Solution Configurator (DCSC).

Configure-to-order (CTO) models are used to create models with factory-integrated server customizations. For CTO models, two types of base CTO models are available for the SD530 as listed in the columns in the following table:

  • General purpose base CTO models are for general business (non-HPC) and is selectable by choosing General Purpose mode in DCSC.
  • AI and HPC base models are intended for Artificial Intelligence (AI) and High Performance Computing (HPC) configurations and solutions are enabled using the AI & HPC Hardware - ThinkSystem Hardware mode in DCSC. These configurations, along with Lenovo EveryScale Solutions, can also be built using System x and Cluster Solutions Configurator (x-config). Tip: Some HPC and AI models are not listed in DCSC and can only be configured in x-config.

Preconfigured server models may also be available for the SD530, however these are region-specific; that is, each region may define their own server models, and not all server models are available in every region.

The following table lists the base CTO models of the ThinkSystem SD530 server.

Table 3. Base CTO models
Machine Type/Model
General purpose
Machine Type/Model
for AI and HPC
Description
7X21CTO1WW 7X21CTOLWW ThinkSystem SD530 – 3-year warranty

The following table lists the base chassis choices for CTO configurations.

Table 4. Base chassis for CTO models
Feature code Description
AUXN ThinkSystem SD530 Computing Node
B0M3 ThinkSystem SD530 Computing Node for GPU Tray

Withdrawn: All Standard and TopSeller models of the SD530 with Xeon SP Gen 1 processors are now withdrawn from marketing. Configure-to-order is still available.  

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Server models for Australia and New Zealand

Table 5. Server models for Australia and New Zealand
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A01VAU 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A025AU 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A02DAU 2x Silver 4108 8C 85W 1.8GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A02LAU 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A02PAU 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A02JAU 2x Silver 4112 4C 85W 2.6GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A020AU 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A02NAU 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A024AU 2x Silver 4116 12C 85W 2.1GHz 2x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A022AU 2x Silver 4116 12C 85W 2.1GHz 2x 32GB RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A02FAU 2x Gold 5118 12C 105W 2.3GHz 2x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A02KAU 2x Gold 5118 12C 105W 2.3GHz 2x 32GB RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A02HAU 2x Gold 6126 12C 125W 2.6GHz 2x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A026AU 2x Gold 6126 12C 125W 2.6GHz 2x 32GB RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A01ZAU 2x Gold 6130 16C 125W 2.1GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A02BAU 2x Gold 6134 8C 130W 3.2GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A023AU 2x Gold 6138 20C 125W 2.0GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A02AAU 2x Gold 6140 18C 140W 2.3GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A021AU 2x Gold 6148 20C 150W 2.4GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for South East Asian countries (ASEAN)

Table 6. Server models for South East Asian countries (ASEAN)
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A00HSG 1x Bronze 3104 6C 85W 1.7GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A004SG 1x Bronze 3106 8C 85W 1.7GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A016SG 1x Silver 4110 8C 85W 2.1GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A011SG 1x Silver 4114 10C 85W 2.2GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A008SG 1x Silver 4116 12C 85W 2.1GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A006SG 1x Gold 5120 14C 105W 2.2GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A00DSG 1x Gold 6130 16C 125W 2.1GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard
7X21A00NSG 1x Gold 6138 20C 125W 2.0GHz 1x 8GB RAID 530-8i 4x SAS/SATA Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for Brazil

Table 7. Server models for Brazil
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A02TBR 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A02UBR 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A02QBR 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A033BR 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A02VBR 2x Silver 4108 8C 85W 1.8GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A02XBR 2x Silver 4108 8C 85W 1.8GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A02YBR 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A030BR 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A031BR 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A032BR 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A02RBR 2x Silver 4112 4C 85W 2.6GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A02SBR 2x Silver 4112 4C 85W 2.6GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A02WBR 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A02ZBR 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A034BR 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A035BR 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for EMEA countries

Table 8. Server models for EMEA countries
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A003EA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A007EA 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A00YEA 2x Silver 4108 8C 85W 1.8GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A018EA 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A01CEA 2x Silver 4110 8C 85W 2.1GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A00TEA 2x Silver 4112 4C 85W 2.6GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A00GEA 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A00SEA 2x Silver 4114 10C 85W 2.2GHz 2x 16GB 2Rx8 RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A01EEA 2x Silver 4116 12C 85W 2.1GHz 2x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A014EA 2x Silver 4116 12C 85W 2.1GHz 2x 32GB RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A00REA 2x Gold 5118 12C 105W 2.3GHz 2x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01DEA 2x Gold 5118 12C 105W 2.3GHz 2x 32GB RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A00WEA 2x Gold 6126 12C 125W 2.6GHz 2x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A010EA 2x Gold 6126 12C 125W 2.6GHz 2x 32GB RAID 530-8i 6x SAS/SATA
(2 AnyBay)
Open Optional Open Standard
7X21A01BEA 2x Gold 6130 16C 125W 2.1GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A019EA 2x Gold 6134 8C 130W 3.2GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A00JEA 2x Gold 6138 20C 125W 2.0GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A005EA 2x Gold 6140 18C 140W 2.3GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A013EA 2x Gold 6148 20C 150W 2.4GHz 2x 32GB RSTe RAID 4x SAS/SATA* Open Optional Open Standard
TopSeller models
7X21A039EA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise
7X21A03AEA 1x Gold 6126 12C 125W 2.6GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise
7X21A03BEA 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise
7X21A03CEA 1x Gold 6134 8C 130W 3.2GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise
7X21A03DEA 1x Gold 6136 12C 150W 3.0GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise
7X21A03EEA 1x Gold 6142 16C 150W 2.6GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise
7X21A03FEA 1x Gold 6150 18C 165W 2.7GHz 1x 16GB 2Rx8 RAID 530-8i 4x SAS/SATA Open Optional Open Enterprise

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for Hong Kong, Taiwan, Korea (HTK)

Table 9. Server models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A01HCN 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A01SCN 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A01QCN 1x Gold 5122 4C 105W 3.6GHz 1x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01PCN 1x Gold 6126 12C 125W 2.6GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A01LCN 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A01RCN 1x Gold 6134 8C 130W 3.2GHz 1x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01TCN 1x Gold 6136 12C 150W 3.0GHz 1x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01FCN 1x Gold 6138 20C 125W 2.0GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A01JCN 1x Gold 6140 18C 140W 2.3GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard
7X21A01NCN 1x Gold 6142 16C 150W 2.6GHz 1x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01GCN 1x Gold 6148 20C 150W 2.4GHz 1x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01KCN 1x Gold 6150 18C 165W 2.7GHz 1x 16GB 2Rx8 RSTe RAID 4x SAS/SATA* Open Optional Open Standard
7X21A01MCN 1x Gold 6152 22C 140W 2.1GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA* Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for India

Table 10. Server models for India
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A00PSG 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A01ASG 1x Silver 4108 8C 85W 1.8GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A009SG 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A00QSG 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A015SG 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A00MSG 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A00LSG 1x Gold 6138 20C 125W 2.0GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A00KSG 1x Gold 6152 22C 140W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for Japan

Table 11. Server models for Japan
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A00AJP 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21A00UJP 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RSTe RAID 6x SAS/SATA* Open Included
+ cable
Open Standard
7X21A036JP 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RSTe RAID 4x SAS/SATA* Open Included
+ cable
Open Standard
7X21A00CJP 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Server models for Latin American (except Brazil)

Table 12. Server models for Latin American (except Brazil)
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X211003LA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X211008LA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X21100DLA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100JLA 1x Bronze 3104 6C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X21A038LA 1x Bronze 3104 6C 85W 1.7GHz 1x 8GB RSTe RAID 4x SAS/SATA* Open Included
+ cable
Open Standard
7X211004LA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X211009LA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X21100ELA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100KLA 1x Bronze 3106 8C 85W 1.7GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X211005LA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100ALA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X21100FLA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100LLA 1x Silver 4116 12C 85W 2.1GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X211006LA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100BLA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X21100GLA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100MLA 1x Gold 5120 14C 105W 2.2GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X211007LA 1x Gold 6140 18C 140W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100CLA 1x Gold 6140 18C 140W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard
7X21100HLA 1x Gold 6140 18C 140W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 6x SAS/SATA Open Optional Open Standard
7X21100NLA 1x Gold 6140 18C 140W 2.3GHz 1x 16GB 1Rx4 RAID 530-8i 4x SAS/SATA Open Included
+ cable
Open Standard

Server models for USA and Canada

Table 13. Server models for USA and Canada
Model Intel Xeon
processors†
Memory RAID Drive bays
(Avail/Max)
Drives KVM
Breakout
M.2
drives
XCC
Level
Standard models
7X21A00VNA 1x Silver 4110 8C 85W 2.1GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A00ZNA 1x Silver 4114 10C 85W 2.2GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A00XNA 1x Gold 5118 12C 105W 2.3GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A017NA 1x Gold 6130 16C 125W 2.1GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard
7X21A012NA 1x Gold 6140 18C 140W 2.3GHz 1x 16GB 2Rx8 RSTe RAID 6x SAS/SATA*
(2 AnyBay)
Open Optional Open Standard

† Processor detail: Quantity, model, core count, TDP, core frequency
* The backplane supports SAS drives, however since the included RAID controller is RSTe, SAS drives are not supported by this model

Enclosure models

Up to four SD530 servers are supported in a D2 Enclosure or a Modular Enclosure.

The following table lists the base CTO models of the enclosures.

Table 14. Base CTO models
Machine Type/Model Description
7X20CTO1WW ThinkSystem D2 Enclosure (3-Year Warranty)
7X22CTO1WW ThinkSystem Modular Enclosure (3-Year Warranty)

The following table lists the base chassis choices for CTO configurations

Table 15. Base chassis for CTO models
Feature code Description
AUXM ThinkSystem D2 Enclosure (for both 7X20 and 7X22)

The preconfigured D2 Enclosure models and Modular Enclosure models are listed in the following table.

The following tables list the available models, grouped by region.

Refer to the Enclosure specifications section for information about standard features of the enclosure.

Enclosure models for Australia and New Zealand

Table 16. Enclosure models for Australia and New Zealand
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00SAU 4-slot x16 shuttle Open 2x 1100W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A012AU 4-slot x16 shuttle Open 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00TAU 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00VAU 4-slot x16 shuttle Open 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A011AU 4-slot x16 shuttle Open 2x 1100W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A013AU 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A010AU 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00XAU 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00ZAU 8-slot x8 shuttle Open 2x 1100W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00UAU 8-slot x8 shuttle Open 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00WAU 8-slot x8 shuttle Open 2x 1100W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00YAU 8-slot x8 shuttle Open 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Included
Modular Enclosure models (Includes the dual-port SMM)
7X221000AU 4-slot x16 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.5m C13-C14 D2 Slide Rail Optional
7X221003AU 4-slot x16 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.5m C13-C14 D2 Slide Rail Optional
7X221001AU 8-slot x8 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.5m C13-C14 D2 Slide Rail Optional
7X221002AU 8-slot x8 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.5m C13-C14 D2 Slide Rail Optional

Enclosure models for South East Asian countries (ASEAN)

Table 17. Enclosure models for South East Asian countries (ASEAN)
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00GSG 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Optional
7X20A00FSG 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Optional

Enclosure models for Brazil

Table 18. Enclosure models for Brazil
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
Modular Enclosure models (Includes the dual-port SMM)
7X22A00BBR 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14 10A D2 Slide Rail Optional
7X22A00CBR 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14 10A D2 Slide Rail Optional

Enclosure models for EMEA countries

Table 19. Enclosure models for EMEA countries
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00HEA 4-slot x16 shuttle Open 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00AEA 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A006EA 4-slot x16 shuttle Open 2x 1100W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00CEA 8-slot x8 shuttle Open 2x 1100W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A004EA 8-slot x8 shuttle Open 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A005EA 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X20A00EEA 8-slot x8 shuttle Open 2x 1600W 2x 2.0m C13-C14 D2 Slide Rail Included
Modular Enclosure models (Includes the dual-port SMM)
7X22A008EA 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included
7X22A006EA 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14 D2 Slide Rail Included

Enclosure models for Hong Kong, Taiwan, Korea (HTK)

Table 20. Enclosure models for Hong Kong, Taiwan, Korea (HTK)
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00BCN 8-slot x8 shuttle 10Gb SFP+ EIOM 2x 1600W 2x 2.8m C13-C14 D2 Slide Rail Optional

Enclosure models for India

Table 21. Enclosure models for India
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00KSG 4-slot x16 shuttle Open 2x 1100W 2x 2.8m C13-C14
2x 2.8m IS 6538
D2 Slide Rail Included
7X20A00QSG 4-slot x16 shuttle Open 2x 1600W 2x 2.8m C13-C14
2x 2.8m IS 6538
D2 Slide Rail Included
7X20A00PSG 4-slot x16 shuttle Open 2x 2000W 2x 2.8m C13-C14
2x 2.8m IS 6538
D2 Slide Rail Included
7X20A00NSG 8-slot x8 shuttle Open 2x 1100W 2x 2.8m C13-C14
2x 2.8m IS 6538
D2 Slide Rail Included
7X20A00LSG 8-slot x8 shuttle Open 2x 2000W 2x 2.8m C13-C14
2x 2.8m IS 6538
D2 Slide Rail Included
7X20A00MSG 8-slot x8 shuttle Open 2x 1600W 2x 2.8m C13-C14
2x 2.8m IS 6538
D2 Slide Rail Included

Enclosure models for Japan

Table 22. Enclosure models for Japan
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00DJP 4-slot x16 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
7X20A009JP 4-slot x16 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
7X20A007JP 8-slot x8 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
7X20A008JP 8-slot x8 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
Modular Enclosure models (Includes the dual-port SMM)
7X22A002JP 4-slot x16 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
7X22A004JP 4-slot x16 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
7X22A001JP 8-slot x8 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included
7X22A007JP 8-slot x8 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Included

Enclosure models for Latin American (except Brazil)

Table 23. Enclosure models for Latin American (except Brazil)
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A019LA 8-slot x8 shuttle 10Gb SFP+ EIOM 2x 1100W 2x 2.0m C13-C14 13A D2 Slide Rail Optional

Enclosure models for USA and Canada

Table 24. Enclosure models for USA and Canada
Model I/O Shuttle External IO Module Power supplies Power cords Rail kit CMA
D2 Enclosure models (Includes the single-port SMM)
7X20A00JNA 4-slot x16 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Optional
7X20A003NA 4-slot x16 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Optional
7X20A00RNA 4-slot x16 shuttle 10Gb SFP+ EIOM 2x 2000W 2x 2.0m C13-C14 D2 Slide Rail Optional
7X20A002NA 8-slot x8 shuttle 10Gb RJ45 EIOM 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Optional
Modular Enclosure models (Includes the dual-port SMM)
7X22A003NA 4-slot x16 shuttle Open 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Optional
7X22A005NA 8-slot x8 shuttle Open 2x 2000W 2x 1.0m C13-C14 D2 Slide Rail Optional

Enclosure support

The SD530 is supported in all models of the D2 Enclosure or Modular Enclosure. The number of servers that are supported in each chassis depends on the TDP value of the processors that are used in the servers, the number and capacity of power supplies installed (1100W, 1600W or 2000W), and the AC input voltage (100 - 127V or 200 - 240V).

All servers installed in an enclosure must have the same drive backplane (for example, all four servers use the 6-drive backplane)

The enclosure supports oversubscription and power supply redundancy options to ensure efficient use of the available system power. By using oversubscription, users can make the most of the extra power from the redundant power supplies when the power supplies are in healthy condition.

Use Lenovo Capacity Planner to determine the exact power needs of the configuration:
https://datacentersupport.lenovo.com/us/en/products/solutions-and-software/software/lenovo-capacity-planner/solutions/ht504651

System power consumption is highly dependent on configuration, workload, and ambient temperature. Lenovo recommends that customers use Lenovo Capacity Planner to select the power supplies best suited for their deployment requirements.

Processor options

The SD530 supports the processor options listed in the following table.

Processors with the T suffix have more robust thermal characteristics (higher T-case). Processors with the M suffix support support greater than 768 GB per processor.

Table 25. Processor options
Part number Feature
code
Description Memory
speed
L3
cache
UPI speed AVX-512
FMA
units
HT TB
4XG7A07683 AXQX Xeon Bronze 3104 6C 85W 1.7GHz 2133 MHz 8.25 MB 9.6 GT/s 1 No No
4XG7A07682 AXQW Xeon Bronze 3106 8C 85W 1.7GHz 2133 MHz 11 MB 9.6 GT/s 1 No No
4XG7A08337 AXQZ Xeon Silver 4108 8C 85W 1.8GHz 2400 MHz 11 MB 9.6 GT/s 1 Yes Yes
4XG7A07681 AXQV Xeon Silver 4109T 8C 70W 2.0GHz 2400 MHz 11 MB 9.6 GT/s 1 Yes Yes
4XG7A07685 AXQY Xeon Silver 4110 8C 85W 2.1GHz 2400 MHz 11 MB 9.6 GT/s 1 Yes Yes
4XG7A07680 AXQU Xeon Silver 4112 4C 85W 2.6GHz 2400 MHz 8.5 MB** 9.6 GT/s 1 Yes Yes
4XG7A07679 AXQT Xeon Silver 4114 10C 85W 2.2GHz 2400 MHz 13.75 MB 9.6 GT/s 1 Yes Yes
4XG7A08338 B139 Xeon Silver 4114T 10C 85W 2.2GHz 2400 MHz 13.75 MB 9.6 GT/s 1 Yes Yes
4XG7A07677 AXNZ Xeon Silver 4116 12C 85W 2.1GHz 2400 MHz 16.5 MB 9.6 GT/s 1 Yes Yes
4XG7A07684 B138 Xeon Silver 4116T 12C 85W 2.1GHz 2400 MHz 16.5 MB 9.6 GT/s 1 Yes Yes
4XG7A07678 AXP0 Xeon Gold 5115 10C 85W 2.4GHz 2400 MHz 13.75 MB 10.4 GT/s 1 Yes Yes
4XG7A09549 B13A Xeon Gold 5117 14C 105W 2.0GHz 2400 MHz 19.25 MB 10.4 GT/s 1 Yes Yes
7XG7A06248 AX7D Xeon Gold 5118 12C 105W 2.3GHz 2400 MHz 16.5 MB 10.4 GT/s 1 Yes Yes
7XG7A06250 AX7F Xeon Gold 5119T 14C 85W 1.9GHz 2400 MHz 19.25 MB 10.4 GT/s 1 Yes Yes
7XG7A06247 AX7C Xeon Gold 5120 14C 105W 2.2GHz 2400 MHz 19.25 MB 10.4 GT/s 1 Yes Yes
7XG7A06249 AX7E Xeon Gold 5120T 14C 105W 2.2GHz 2400 MHz 19.25 MB 10.4 GT/s 1 Yes Yes
7XG7A06237 AX70 Xeon Gold 5122 4C 105W 3.6GHz 2666 MHz* 16.5 MB** 10.4 GT/s 2* Yes Yes
7XG7A06234 AWEX Xeon Gold 6126 12C 125W 2.6GHz 2666 MHz 19.25 MB** 10.4 GT/s 2 Yes Yes
4XG7A11375 B328 Xeon Gold 6126T 12C 125W 2.6GHz 2666 MHz 19.25 MB** 10.4 GT/s 2 Yes Yes
7XG7A06236 AX6Z Xeon Gold 6128 6C 115W 3.4GHz 2666 MHz 19.25 MB** 10.4 GT/s 2 Yes Yes
7XG7A06229 AX6D Xeon Gold 6130 16C 125W 2.1GHz 2666 MHz 22 MB 10.4 GT/s 2 Yes Yes
7XG7A06239 AX72 Xeon Gold 6130T 16C 125W 2.1GHz 2666 MHz 22 MB 10.4 GT/s 2 Yes Yes
7XG7A06232 AX6U Xeon Gold 6132 14C 140W 2.6GHz 2666 MHz 19.25 MB 10.4 GT/s 2 Yes Yes
7XG7A06235 AX6Y Xeon Gold 6134 8C 130W 3.2GHz 2666 MHz 24.75 MB** 10.4 GT/s 2 Yes Yes
7XG7A06245 AX7A Xeon Gold 6134M 8C 130W 3.2GHz 2666 MHz 24.75 MB** 10.4 GT/s 2 Yes Yes
7XG7A06233 AX6W Xeon Gold 6136 12C 150W 3.0GHz 2666 MHz 24.75 MB** 10.4 GT/s 2 Yes Yes
7XG7A06227 AX6Q Xeon Gold 6138 20C 125W 2.0GHz 2666 MHz 27.5 MB 10.4 GT/s 2 Yes Yes
7XG7A06238 AX71 Xeon Gold 6138T 20C 125W 2.0GHz 2666 MHz 27.5 MB 10.4 GT/s 2 Yes Yes
7XG7A06228 AX6R Xeon Gold 6140 18C 140W 2.3GHz 2666 MHz 24.75 MB 10.4 GT/s 2 Yes Yes
7XG7A06244 AX79 Xeon Gold 6140M 18C 140W 2.3GHz 2666 MHz 24.75 MB 10.4 GT/s 2 Yes Yes
7XG7A06231 AX6E Xeon Gold 6142 16C 150W 2.6GHz 2666 MHz 22 MB 10.4 GT/s 2 Yes Yes
7XG7A06243 AX78 Xeon Gold 6142M 16C 150W 2.6GHz 2666 MHz 22 MB 10.4 GT/s 2 Yes Yes
4XG7A11376 B325 Xeon Gold 6144 8C 150W 3.5GHz 2666 MHz 24.75 MB** 10.4 GT/s 2 Yes Yes
4XG7A11377 B326 Xeon Gold 6146 12C 165W 3.2GHz 2666 MHz 24.75 MB** 10.4 GT/s 2 Yes Yes
7XG7A06226 AWEW Xeon Gold 6148 20C 150W 2.4GHz 2666 MHz 27.5 MB 10.4 GT/s 2 Yes Yes
7XG7A06230 AX6T Xeon Gold 6150 18C 165W 2.7GHz 2666 MHz 24.75 MB 10.4 GT/s 2 Yes Yes
7XG7A06225 AX6P Xeon Gold 6152 22C 140W 2.1GHz 2666 MHz 30.25 MB 10.4 GT/s 2 Yes Yes
4XG7A11378 B327 Xeon Gold 6154 18C 200W 3.0GHz 2666 MHz 24.75 MB 10.4 GT/s 2 Yes Yes
7XG7A06223 AX6L Xeon Platinum 8153 16C 125W 2.0GHz 2666 MHz 22 MB 10.4 GT/s 2 Yes Yes
7XG7A06224 AWEV Xeon Platinum 8156 4C 105W 3.6GHz 2666 MHz 16.5 MB** 10.4 GT/s 2 Yes Yes
7XG7A06246 AX7B Xeon Platinum 8158 12C 150W 3.0GHz 2666 MHz 24.75 MB** 10.4 GT/s 2 Yes Yes
7XG7A06222 AWGJ Xeon Platinum 8160 24C 150W 2.1GHz 2666 MHz 33 MB 10.4 GT/s 2 Yes Yes
7XG7A06242 AX77 Xeon Platinum 8160M 24C 150W 2.1GHz 2666 MHz 33 MB 10.4 GT/s 2 Yes Yes
4XG7A11379 B32C Xeon Platinum 8160T 24C 150W 2.1GHz 2666 MHz 33 MB 10.4 GT/s 2 Yes Yes
7XG7A06221 AX6K Xeon Platinum 8164 26C 150W 2.0GHz 2666 MHz 35.75 MB 10.4 GT/s 2 Yes Yes
4XG7A11380 B329 Xeon Platinum 8168 24C 205W 2.7GHz 2666 MHz 33 MB 10.4 GT/s 2 Yes Yes
7XG7A06220 AX6J Xeon Platinum 8170 26C 165W 2.1GHz 2666 MHz 35.75 MB 10.4 GT/s 2 Yes Yes
7XG7A06241 AX76 Xeon Platinum 8170M 26C 165W 2.1GHz 2666 MHz 35.75 MB 10.4 GT/s 2 Yes Yes
7XG7A06219 AX6H Xeon Platinum 8176 28C 165W 2.1GHz 2666 MHz 38.5 MB 10.4 GT/s 2 Yes Yes
7XG7A06240 AX75 Xeon Platinum 8176M 28C 165W 2.1GHz 2666 MHz 38.5 MB 10.4 GT/s 2 Yes Yes
4XG7A11381 B32B Xeon Platinum 8180 28C 205W 2.5GHz 2666 MHz 38.5 MB 10.4 GT/s 2 Yes Yes
4XG7A11382 B32A Xeon Platinum 8180M 28C 205W 2.5GHz 2666 MHz 38.5 MB 10.4 GT/s 2 Yes Yes

* All Gold 5000-level processors, except the 5122, support 2400 MHz memory speeds and have one AVX-512 512-bit FMA units. The 5122 processor supports 2666 MHz and has two FMA units
** L3 cache is 1.375 MB per core except with the processor indicated with **

The processors in the SD530 require specific heatsinks depending on their thermal profile of the processor:

  • 85mm heatsinks are used on processors with low thermal requirements. This heatsink allows the use of 16 DIMMs and the use of a storage adapter in the PCIe slot at the rear of the server
  • 108mm heatsinks are used on CPU 1 when the processors installed have medium thermal requirements. Due to its shape, this heatsink limits the number of DIMMs to 12. A storage adapter can be used with these processors. Only CPU 1 (rear) needs this larger heatsink; CPU 2 (front) uses an 85mm heatsink.
  • Thermal Transfer Module heatsinks are used on CPU 1 when the processors installed have high thermal requirements. The Thermal Transfer Module is two heatsinks connected together via thermal pipes as shown in the following figure. Due to its shape, this heatsink prevents an adapter (RAID or HBA) from being installed in PCIe slot 1 at the rear of the server and limits the number of DIMMs to 12. CPU 2 will use a larger 102mm heatsink in such configurations.

The Thermal Transfer Module (TTM) heatsink is shown in the following figure. For additional information, see the Lenovo Press article, The Benefits of Lenovo Thermal Transfer Module Technology in ThinkSystem SD530 Servers, https://lenovopress.com/lp0922.

Lenovo Thermal Transfer Module
Figure 8. Thermal Transfer Module

The following table lists the heatsink used for each processor model, and the resulting support for 16 DIMMs and support for a RAID adapter or HBA. The table also lists which processors (those with an M suffix) that support more than 768 GB per processor (1.5TB for two processors).

16 DIMM support: The use of 16 DIMMs requires that smaller heatsinks be used. As a result, only a subset of processors support 16 DIMMs (8 DIMMs per processor), as noted in the table below. All others are limited to 12 DIMMs (6 DIMMs processors).

Drive bay support: Only a subset of processors support 6 drive bays. See the Drive bays and backplanes section for details.

Storage adapter support: Some procesors require the larger T-shaped Thermal Transfer Module heatsink which precludes the use of the RAID adapter or HBA installed in the dedicated slot at the rear of the server.

Table 26. Processor support for server features
Intel Xeon Processor Heatsink
for CPU1
Supports
16 DIMMs†
Supports
Storage
Adapter‡
Supports
>768 GB
per CPU
Intel Xeon Bronze 3104 6C 85W 1.7GHz 85mm Yes Yes No
Intel Xeon Bronze 3106 8C 85W 1.7GHz 85mm Yes Yes No
Intel Xeon Silver 4108 8C 85W 1.8GHz 85mm Yes Yes No
Intel Xeon Silver 4109T 8C 70W 2.0GHz 108mm No Yes No
Intel Xeon Silver 4110 8C 85W 2.1GHz 85mm Yes Yes No
Intel Xeon Silver 4112 4C 85W 2.6GHz 85mm Yes Yes No
Intel Xeon Silver 4114 10C 85W 2.2GHz 85mm Yes Yes No
Intel Xeon Silver 4114T 10C 85W 2.2GHz 108mm No Yes No
Intel Xeon Silver 4116 12C 85W 2.1GHz 85mm Yes Yes No
Intel Xeon Silver 4116T 12C 85W 2.1GHz 108mm No Yes No
Intel Xeon Gold 5115 10C 85W 2.4GHz 85mm Yes Yes No
Intel Xeon Gold 5117 14C 105W 2.0GHz 108mm No Yes No
Intel Xeon Gold 5118 12C 105W 2.3GHz 85mm Yes Yes No
Intel Xeon Gold 5119T 14C 85W 1.9GHz 108mm No Yes No
Intel Xeon Gold 5120 14C 105W 2.2GHz 85mm Yes Yes No
Intel Xeon Gold 5120T 14C 105W 2.2GHz 108mm No Yes No
Intel Xeon Gold 5122 4C 105W 3.6GHz 108mm No Yes No
Intel Xeon Gold 6126 12C 125W 2.6GHz 108mm No Yes No
Intel Xeon Gold 6126T 12C 125W 2.6GHz TTM No No No
Intel Xeon Gold 6128 6C 115W 3.4GHz 108mm No Yes No
Intel Xeon Gold 6130 16C 125W 2.1GHz 85mm Yes Yes No
Intel Xeon Gold 6130T 16C 125W 2.1GHz 108mm No Yes No
Intel Xeon Gold 6132 14C 140W 2.6GHz 108mm No Yes No
Intel Xeon Gold 6134 8C 130W 3.2GHz 108mm No Yes No
Intel Xeon Gold 6134M 8C 130W 3.2GHz 108mm No Yes Yes
Intel Xeon Gold 6136 12C 150W 3.0GHz 108mm No Yes No
Intel Xeon Gold 6138 20C 125W 2.0GHz 108mm No Yes No
Intel Xeon Gold 6138T 20C 125W 2.0GHz 108mm No Yes No
Intel Xeon Gold 6140 18C 140W 2.3GHz 108mm No Yes No
Intel Xeon Gold 6140M 18C 140W 2.3GHz 108mm No Yes Yes
Intel Xeon Gold 6142 16C 150W 2.6GHz 108mm No Yes No
Intel Xeon Gold 6142M 16C 150W 2.6GHz 108mm No Yes Yes
Intel Xeon Gold 6144 8C 150W 3.5GHz TTM No No No
Intel Xeon Gold 6146 12C 165W 3.2GHz TTM No No No
Intel Xeon Gold 6148 20C 150W 2.4GHz 108mm No Yes No
Intel Xeon Gold 6150 18C 165W 2.7GHz 108mm No Yes No
Intel Xeon Gold 6152 22C 140W 2.1GHz 108mm No Yes No
Intel Xeon Gold 6154 18C 200W 3.0GHz TTM No No No
Intel Xeon Platinum 8153 16C 125W 2.0GHz 85mm Yes Yes No
Intel Xeon Platinum 8156 4C 105W 3.6GHz 108mm No Yes No
Intel Xeon Platinum 8158 12C 150W 3.0GHz 108mm No Yes No
Intel Xeon Platinum 8160 24C 150W 2.1GHz 108mm No Yes No
Intel Xeon Platinum 8160M 24C 150W 2.1GHz 108mm No Yes Yes
Intel Xeon Platinum 8160T 24C 150W 2.1GHz TTM No No No
Intel Xeon Platinum 8164 26C 150W 2.0GHz 108mm No Yes No
Intel Xeon Platinum 8168 24C 205W 2.7GHz TTM No No No
Intel Xeon Platinum 8170 26C 165W 2.1GHz 108mm No Yes No
Intel Xeon Platinum 8170M 26C 165W 2.1GHz 108mm No Yes Yes
Intel Xeon Platinum 8176 28C 165W 2.1GHz 108mm No Yes No
Intel Xeon Platinum 8176M 28C 165W 2.1GHz 108mm No Yes Yes
Intel Xeon Platinum 8180 28C 205W 2.5GHz TTM No No No
Intel Xeon Platinum 8180M 28C 205W 2.5GHz TTM No No Yes

† With 16 DIMMs, drive bays are limited to 4x 2.5-inch SAS/SATA drives or 4x 2.5-inch NVMe drives (6 drive bays not supported). See the Drive bays and backplanes section for details.
‡ No in this column means no support for ThinkSystem SD530 HW RAID Kit or ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA

Memory options

The SD530 server supports TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned to maximize performance and reliability.

TruDDR4 memory has a unique signature programmed into the DIMM, which enables ThinkSystem servers to verify whether the memory installed is qualified and supported. From a service and support standpoint, TruDDR4 memory automatically assumes the system's warranty, and service and support provided worldwide.

Each processor has six memory channels. All DIMMs operate at a speed of 2666 MHz. However, if the processor selected has a lower memory bus speed (eg 2400 MHz or 2133 MHz - see the Processor options table), then all DIMMs will operate at that lower speed.

The SD530 supports up to 6 or 8 DIMMs per processor, for a total of 12 or 16 DIMMs when two processors are installed. The total DIMMs supported depends on the processor selected, as described in the Processor options section.

The following table lists the memory options that are available for the SD530 server.

Table 27. Memory options
Part
number
Feature
code
Description Maximum
supported*
RDIMMs
7X77A01301 AUU1 ThinkSystem 8GB TruDDR4 2666 MHz (1Rx8 1.2V) RDIMM 16 (8 per processor)
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 16 (8 per processor)
7X77A01303 AUNC ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM 16 (8 per processor)
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 16 (8 per processor)
LRDIMMs
7X77A01305 AUNE ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM 16 (8 per processor)
3DS RDIMMs
7X77A01307 AUNF ThinkSystem 128GB TruDDR4 2666 MHz (8Rx4 1.2V) 3DS RDIMM 12 (6 per processor)†

* Some SD530 configurations only support 6 DIMMs per processor (12 total) depending on the processor selected, as described in the Processor options section.
† 12 is the effective maximum number of 128 GB DIMMs that the SD530 supports, since using any more than 12x 128 GB DIMMs requires an M-suffix processor, and the heatsink required for all M-suffix processors prevents more than 12 DIMM slots.

The following rules apply when selecting the memory configuration:

  • The server supports RDIMMs and LRDIMMs.
  • Mixing RDIMMs and LRDIMMs is not supported.
  • Mixing 3DS RDIMMs with either RDIMMs or LRDIMMs is not supported.
  • It is supported to mix x4 and x8 DIMMs.
  • The following rules apply to support 16 DIMMs:
    • Only a subset of the supported processors can be used, as indicated in the Processor specifications table in the Processor section.
    • Smaller processor heatsinks will be automatically selected by the configurator so that the four additional DIMM slots are accessible.
    • Only the 2x2 SAS/SATA backplane can be selected as described in the Drive bays and backplanes section. The 2x3 backplanes are not supported and no NVMe drives are supported.
  • Each processor has 6 memory channels. As a result, for best performance, populate memory DIMMs in quantities of 6 or 12 per processor, so that all memory channels are used, however, to maximize capacity, select a processor that in the SD530 supports 8 DIMMs per processor and install 16 DIMMs.

Tip: To learn more about the performance implications of using 16 DIMMs in the SD530, read the Lenovo Press paper Lenovo ThinkSystem SD530 Performance Considerations with 12 DIMMs and 16 DIMMs available from: http://lenovopress.com/LP0659

The following memory protection technologies are supported:

  • ECC
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • ADDDC (for x4-based memory DIMMs; Gold and Platinum processors only)
  • Memory channel mirroring
  • Memory rank sparing

If memory channel mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per processor), and both DIMMs in a pair must be identical in type and size. 50% of the installed capacity is available to the operating system.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The largest rank in the channel will be automatically selected as the spare rank. The amount of memory available to the operating system depends on the number, capacity and rank counts of the DIMMs installed.

Internal storage

The SD530 supports up to six 2.5-inch hot-swap drive bays, all of which are accessible from the front of the server.

In this section:

Drive bays and backplanes

The server supports three different drive bay configurations, all comprised of 2.5-inch hot-swap drive bays:

  • Six drive bays, four bays supporting SAS or SATA drives and two Lenovo AnyBay bays, supporting NVMe, SAS or SATA drives
  • Five drive bays, three of which are SAS/SATA and two are AnyBay bays. This configuration also includes a KVM breakout module to provide front-accessible VGA, Serial and USB ports.
  • Four drive bays, all of which are SAS/SATA drive bays or all of which are NVMe. These configurations also support an optional KVM breakout module.

The three configurations are shown in the following figure. When the AnyBay backplane is selected the rightmost two drives are the AnyBay drive bays. AnyBay is the term for a bay with a U.2 connector that has both SAS/SATA and NVMe connections. It is designed to support either a SAS, SATA or NVMe drive.

Enclosure requirement: All servers installed in an enclosure must have the same drive backplane (for example, all four servers use the 6-drive backplane).

Drive bay configurations of the SD530
Figure 9. Drive bay configurations of the SD530

The drive bay configurations are made available through the use of either a 2x3 SAS/SATA backplane, 2x3 AnyBay backplane, a 2x2 SAS/SATA backplane or a 2x2 NVMe backplane. Ordering details are listed in the following table.

Processor 2 needed for AnyBay: The use of AnyBay or NVMe requires that processor 2 be installed. Processor 2 provides the necessary PCIe connectivity.

Table 28. Backplane ordering information
Part
number
Feature
code
Description Drive bay
configuration
None* AUYG ThinkSystem SD530 3x2 SAS/SATA BP 6x SAS/SATA
5x SAS/SATA
None* AUYH ThinkSystem SD530 3x2 SAS/SATA/NVMe BP 4x SAS/SATA + 2 AnyBay
3x SAS/SATA + 2 AnyBay
None* AUYJ ThinkSystem SD530 2x2 SAS/SATA BP 4x SAS/SATA
None* B324 ThinkSystem SD530 2.5" NVMe 4-Bay Backplane Kit 4x NVMe

* Available in predefined models or configure-to-order only

Not all processor selections support the 3x2 backplanes, and some ony support 3x2 backplanes when 12 DIMMs are installed. The following table shows the supported combinations.

Tip: Support is based on the cooling needs of the processor, not the TDP or core frequency.

Table 29. Backplane support by processor
Intel Xeon processor 12 DIMMs 16 DIMMs
2x2 backplane 2x3 backplane 2x2 backplane 2x3 backplane
Bronze 3104 6C 85W 1.7GHz Yes Yes Yes No
Bronze 3106 8C 85W 1.7GHz Yes Yes Yes No
Silver 4108 8C 85W 1.8GHz Yes Yes Yes No
Silver 4109T 8C 70W 2.0GHz Yes No No No
Silver 4110 8C 85W 2.1GHz Yes Yes Yes No
Silver 4112 4C 85W 2.6GHz Yes Yes Yes No
Silver 4114 10C 85W 2.2GHz Yes Yes Yes No
Silver 4114T 10C 85W 2.2GHz Yes No No No
Silver 4116 12C 85W 2.1GHz Yes Yes Yes No
Silver 4116T 12C 85W 2.1GHz Yes No No No
Gold 5115 10C 85W 2.4GHz Yes Yes Yes No
Gold 5117 14C 105W 2.0GHz Yes Yes No No
Gold 5118 12C 105W 2.3GHz Yes Yes Yes No
Gold 5119T 14C 85W 1.8GHz Yes No No No
Gold 5120 14C 105W 2.2GHz Yes Yes Yes No
Gold 5120T 14C 105W 2.2GHz Yes No No No
Gold 5122 4C 105W 3.6GHz Yes No No No
Gold 6126 12C 125W 2.6GHz Yes Yes No No
Gold 6126T 12C 125W 2.6GHz Yes No No No
Gold 6128 6C 115W 3.4GHz Yes No No No
Gold 6130 16C 125W 2.1GHz Yes Yes Yes No
Gold 6130T 16C 125W 2.1GHz Yes No No No
Gold 6132 14C 140W 2.6GHz Yes No No No
Gold 6134 8C 130W 3.2GHz Yes No No No
Gold 6134M 8C 130W 3.2GHz Yes No No No
Gold 6136 12C 150W 3.0GHz Yes No No No
Gold 6138 20C 125W 2.0GHz Yes Yes No No
Gold 6138T 20C 125W 2.0GHz Yes No No No
Gold 6140 18C 140W 2.3GHz Yes Yes No No
Gold 6140M 18C 140W 2.3GHz Yes Yes No No
Gold 6142 16C 150W 2.6GHz Yes No No No
Gold 6142M 16C 150W 2.6GHz Yes No No No
Gold 6144 8C 150W 3.5GHz Yes No No No
Gold 6146 12C 165W 3.2GHz Yes No No No
Gold 6148 20C 150W 2.4GHz Yes No No No
Gold 6150 18C 165W 2.7GHz Yes No No No
Gold 6152 22C 140W 2.1GHz Yes Yes No No
Gold 6154 18C 200W 3.0GHz Yes No No No
Platinum 8153 16C 125W 2.0GHz Yes Yes Yes No
Platinum 8156 4C 105W 3.6GHz Yes No No No
Platinum 8158 12C 150W 3.0GHz Yes No No No
Platinum 8160 24C 150W 2.1GHz Yes No No No
Platinum 8160M 24C 150W 2.1GHz Yes No No No
Platinum 8160T 24C 150W 2.1GHz Yes No No No
Platinum 8164 26C 150W 2.0GHz Yes No No No
Platinum 8168 24C 205W 2.7GHz Yes No No No
Platinum 8170 26C 165W 2.1GHz Yes No No No
Platinum 8170M 26C 165W 2.1GHz Yes No No No
Platinum 8176 28C 165W 2.1GHz Yes No No No
Platinum 8176M 28C 165W 2.1GHz Yes No No No
Platinum 8180 28C 205W 2.5GHz Yes No No No
Platinum 8180M 28C 205W 2.5GHz Yes No No No

Adapters and cabling

The SD530 supports the following backplane connectivity:

  • Hardware RAID adapter installed in a dedicated slot at the back of the server - supporting SAS or SATA drives
  • Software RAID from the embedded Intel RSTe controller - supporting only SATA drives
  • PCIe NVMe connectivity for the AnyBay backplane from the PCIe connector #3 on the system board which is routed from Processor 2.
  • PCIe NVMe connectivity for the 2x2 NVMe backplane from the PCIe connectors #3 and #4 on the system board which is routed from Processor 2.

These connectors are shown in the Internal view of the server in the Components and connectors section.

Tip: The controllers are described in detail in the Controllers for internal storage section.

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 30. M.2 components
Part number Feature code Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

Controllers for internal storage

The SD530 supports the following RAID controllers for internal storage:

  • 12 Gb SAS/SATA RAID adapter installed in a dedicated slot
  • 12 Gb SAS/SATA HBA installed in a dedicated slot
  • Intel RSTe 6 Gb SATA software RAID controller integrated in the the Intel chipset

Storage adapters with high-end processors: The use of processors with a high thermal profile such as the 205W processors preclude the use of the RAID adapter or the HBA. See Processor options for specifics. With such processors, only the onboard Intel RSTe 6 Gb SATA software RAID controller can be used.

Virtualization support: The onboard SATA ports can be used with virtualization hypervisors, including VMware ESXi, Linux KVM, Xen, and Microsoft Hyper-V, however support is limited to AHCI (non-RAID) mode. RSTe mode is not supported with virtualization hypervisors.

The following table lists the ordering information.

Table 31. RAID controllers
Part
number
Feature
code
Description
None AUYL ThinkSystem SD530 SW RAID Kit
4C57A16216 AUYK ThinkSystem SD530 HW RAID Kit (RAID 530-8i equivalent)
4C57A16217 B0SS ThinkSystem 430-8i SAS/SATA 12Gb Dense HBA
Table 32. Controller specifications
Feature Intel RSTe 430-8i Dense SD530 RAID
Adapter type Software RAID HBA RAID controller
Part number None 4C57A16217 4C57A16216
Form factor Onboard Custom Custom
Controller chip Intel PCH (RSTe) LSI SAS3408 LSI SAS3408
Host interface Not applicable PCIe 3.0 x8 PCIe 3.0 x8
Port interface 6 Gb SATA 12 Gb SAS 12 Gb SAS
Number of ports 6 6 6
Port connectors 2x onboard SATA 2x SlimSAS x4 2x SlimSAS x4
Drive interface SATA SAS, SATA SAS, SATA
Drive type HDD, SSD HDD, SSD, SED** HDD, SSD, SED
Hot-swap drives No Yes Yes
Max devices Varies 8 6
RAID levels 0, 1, 10, 5 No RAID 0, 1, 10, 5, 50
JBOD mode Yes Yes Yes
Cache None No None
CacheVault cache protection No No No
Performance Accelerator (FastPath) No No Yes
SSD Caching (CacheCade Pro 2.0) No No No
SED support No Yes** Yes (SafeStore)

** The SAS/SATA HBA supports SEDs (self-encrypting drives) by using software on the server and simply passing SED commands through the HBA to the drives.

Internal drive options

The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.

M.2 drives:

M.2 drive support: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

PCIe 4.0 NVMe drive support: When installed in this server, PCIe 4.0 NVMe drives will operate at PCIe 3.0 speeds.

Table 33. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD 6
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD 6
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD 6
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 6
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 6
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00070 B0YV ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD FIPS 6
2.5-inch hot-swap SED HDDs - 12 Gb NL SAS
7XB7A00064 B0YM ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512e HDD FIPS 6
Table 34. 2.5-inch hot-swap 6 Gb SATA HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 6
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD 6
Table 35. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 12 Gb SAS - Performance (10+ DWPD)
4XB7A10219 B4Y4 ThinkSystem 2.5" SS530 400GB Performance SAS 12Gb Hot Swap SSD 6
4XB7A10230 B4Y5 ThinkSystem 2.5" SS530 800GB Performance SAS 12Gb Hot Swap SSD 6
4XB7A10231 B4Y6 ThinkSystem 2.5" SS530 1.6TB Performance SAS 12Gb Hot Swap SSD 6
4XB7A10232 B4Y7 ThinkSystem 2.5" SS530 3.2TB Performance SAS 12Gb Hot Swap SSD 6
7N47A00124 AUMG ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD 6
7N47A00125 AUMH ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD 6
7N47A00126 AVRB ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD 6
2.5-inch hot-swap SSDs - 12 Gb SAS - Mainstream (3-5 DWPD)
4XB7A17062 B8HU ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD 6
4XB7A17063 B8J4 ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 6
4XB7A17064 B8JD ThinkSystem 2.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD 6
4XB7A17065 B8JA ThinkSystem 2.5" PM1645a 6.4TB Mainstream SAS 12Gb Hot Swap SSD 6
4XB7A13653 B4A0 ThinkSystem 2.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD 6
4XB7A13654 B4A1 ThinkSystem 2.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD 6
4XB7A13655 B4A2 ThinkSystem 2.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD 6
7N47A00117 AUMC ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD 6
7N47A00118 AUMD ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD 6
7N47A00119 AVRG ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 6
7N47A00120 AVRJ ThinkSystem 2.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD 6
2.5-inch hot-swap SSDs - 12 Gb SAS - Entry / Capacity (<3 DWPD)
4XB7A38175 B91A ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD 6
4XB7A38176 B91B ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD 6
4XB7A17054 B91C ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD 6
4XB7A17055 B91D ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD 6
4XB7A17056 BC4R ThinkSystem 2.5" PM1643a 15.36TB Entry SAS 12Gb Hot Swap SSD 6
4XB7A17168 B6TL ThinkSystem 2.5" PM1643 960GB Entry SAS 12Gb Hot Swap SSD 6
4XB7A13645 B4A7 ThinkSystem 2.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD 6
4XB7A13646 B4A6 ThinkSystem 2.5" PM1643 7.68TB Capacity SAS 12Gb Hot Swap SSD 6
7N47A00121 AUMK ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD 6
7N47A00122 AUML ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD 6
7N47A00123 B116 ThinkSystem 2.5" PM1633a 15.36TB Capacity SAS 12Gb Hot Swap SSD 6
2.5-inch hot-swap SED SSDs - 12 Gb SAS - Performance (10+ DWPD)
7SD7A05754 B11P ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS 6
7SD7A05753 B11Q ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS 6
7SD7A05752 B11R ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS 6
Table 36. 2.5-inch hot-swap 6 Gb SATA SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 6 Gb SATA - Mainstream (3-5 DWPD)
4XB7A17087 B8J1 ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A17088 B8HY ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A17089 B8J6 ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A17090 B8JE ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A17091 B8J7 ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A13633 B49L ThinkSystem 2.5" Intel S4610 240GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A13634 B49M ThinkSystem 2.5" Intel S4610 480GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A13635 B49N ThinkSystem 2.5" Intel S4610 960GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A13636 B49P ThinkSystem 2.5" Intel S4610 1.92TB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A10237 B488 ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A10238 B489 ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A10239 B48A ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A10240 B48B ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD 6
4XB7A10241 B48C ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05723 B0ZP ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05722 B0ZQ ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05721 B0ZR ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05720 B0ZS ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05765 B10W ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05764 B10X ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05763 B10Y ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05762 B10Z ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD 6
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 6
2.5-inch hot-swap SSDs - 6 Gb SATA - Entry (<3 DWPD)
4XB7A38271 BCTC ThinkSystem 2.5" Multi Vendor 240GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A38272 BCTD ThinkSystem 2.5" Multi Vendor 480GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A38273 BCTE ThinkSystem 2.5" Multi Vendor 960GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A38274 BCTF ThinkSystem 2.5" Multi Vendor 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A38275 BCTG ThinkSystem 2.5" Multi Vendor 3.84TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A17075 B8HV ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A17076 B8JM ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A17077 B8HP ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A17078 B8J5 ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A17079 B8JP ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A17080 B8J2 ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A38144 B7EW ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD 6
4XB7A38145 B7EX ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD 6
4XB7A38146 B7EY ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD 6
4XB7A10247 B498 ThinkSystem 2.5" Intel S4510 240GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10248 B499 ThinkSystem 2.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10249 B49A ThinkSystem 2.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A13622 B49B ThinkSystem 2.5" Intel S4510 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A13623 B49C ThinkSystem 2.5" Intel S4510 3.84TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10195 B34H ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10196 B34J ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10197 B34K ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10198 B34L ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10199 B34M ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10200 B4D2 ThinkSystem 2.5" PM883 7.68TB Entry SATA 6Gb Hot Swap SSD 6
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 6
7SD7A05741 B0YZ ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD 6
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 6
7SD7A05739 B0Z1 ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD 6
7SD7A05738 B0Z2 ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD 6
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 6
7N47A00112 AUM9 ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD 6
7N47A00113 AVCZ ThinkSystem 2.5" PM863a 960GB Entry SATA 6Gb Hot Swap SSD 6
7N47A00114 AVRC ThinkSystem 2.5" PM863a 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10155 B2X4 ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10156 B2X5 ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A10157 B2X6 ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A08502 B10N ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A08503 B10P ThinkSystem 2.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD 6
4XB7A08504 B10Q ThinkSystem 2.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD 6
4XB7A08505 B10R ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD 6
7N47A00099 AUM8 ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD 6
7N47A00100 AUUZ ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD 6
2.5-inch hot-swap SED SSDs - 6 Gb SATA - Mainstream (3-5 DWPD)
4XB7A38193 B93K ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED 6
4XB7A13981 B93J ThinkSystem 2.5" 5200 (Max) 1.92TB Mainstream SATA 6Gb Hot Swap SSD SED 6
2.5-inch hot-swap SED SSDs - 6 Gb SATA - Entry (<3 DWPD)
4XB7A38141 BE29 ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD SED 6
4XB7A38191 B93L ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD SED 6
4XB7A38192 B93M ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD SED 6
Table 37. 2.5-inch hot-swap PCIe 4.0 NVMe SSDs (operate at PCIe 3.0 speeds in this server)
Part number Feature Description Maximum
supported
2.5-inch SSDs - PCIe 4.0 NVMe - Mainstream (3-5 DWPD)
4XB7A17152 BCFV ThinkSystem U.2 Intel P5600 1.6TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD 4
4XB7A17153 BCFR ThinkSystem U.2 Intel P5600 3.2TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD 4
4XB7A17154 BCFS ThinkSystem U.2 Intel P5600 6.4TB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD 4
4XB7A64175 BE03 ThinkSystem U.3 Kioxia CM6-V 800GB Mainstream NVMe PCIe 4.0 x4 Hot Swap SSD 4
4XB7A17112 B96Z ThinkSystem U.3 Kioxia CM6-V 1.6TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD 4
4XB7A17113 B96T ThinkSystem U.3 Kioxia CM6-V 3.2TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD 4
4XB7A17114 B96P ThinkSystem U.3 Kioxia CM6-V 6.4TB Mainstream NVMe PCIe4.0 x4 Hot Swap SSD 4
2.5-inch SSDs - PCIe 4.0 NVMe - Entry (<3 DWPD)
4XB7A17145 BCFT ThinkSystem U.2 Intel P5500 1.92TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD 4
4XB7A17146 BCFW ThinkSystem U.2 Intel P5500 3.84TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD 4
4XB7A17147 BCFU ThinkSystem U.2 Intel P5500 7.68TB Entry NVMe PCIe 4.0 x4 Hot Swap SSD 4
Table 38. 2.5-inch hot-swap PCIe 3.0 NVMe SSDs
Part number Feature Description Maximum
supported
2.5-inch SSDs - PCIe 3.0 NVMe - Performance (10+ DWPD)
7N47A00081 AUMJ ThinkSystem U.2 Intel Optane P4800X 375GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 4
7N47A00083 B2ZJ ThinkSystem U.2 Intel Optane P4800X 750GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 4
7XB7A05923 AWG6 ThinkSystem U.2 PX04PMB 800GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 4
7XB7A05922 AWG7 ThinkSystem U.2 PX04PMB 1.6TB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 4
2.5-inch SSDs - PCIe 3.0 NVMe - Mainstream (3-5 DWPD)
4XB7A13936 B589 ThinkSystem U.2 Intel P4610 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 4
4XB7A13937 B58A ThinkSystem U.2 Intel P4610 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 4
4XB7A13938 B58B ThinkSystem U.2 Intel P4610 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 4
4XB7A08516 B21W ThinkSystem U.2 Toshiba CM5-V 800GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A08517 B21X ThinkSystem U.2 Toshiba CM5-V 1.6TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A08518 B21Y ThinkSystem U.2 Toshiba CM5-V 3.2TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A08519 B2XJ ThinkSystem U.2 Toshiba CM5-V 6.4TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 4
7N47A00095 AUUY ThinkSystem U.2 PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 4
7N47A00096 AUMF ThinkSystem U.2 PX04PMB 1.92TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 4
7SD7A05772 B11J ThinkSystem U.2 Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 4
7SD7A05771 B11K ThinkSystem U.2 Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 4
2.5-inch SSDs - PCIe 3.0 NVMe - Entry (<3 DWPD)
4XB7A10202 B58F ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
4XB7A10204 B58G ThinkSystem U.2 Intel P4510 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
4XB7A10205 B58H ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
4XB7A10175 B34N ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10176 B34P ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10177 B4D3 ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
7SD7A05779 B11C ThinkSystem U.2 Intel P4500 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
7SD7A05778 B11D ThinkSystem U.2 Intel P4500 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
7SD7A05777 B11E ThinkSystem U.2 Intel P4500 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 4
2.5-inch SED SSDs - PCIe 3.0 NVMe - Entry (<3 DWPD)
4XB7A14058 B6K2 ThinkSystem U.2 CM5-R 960GB Entry NVMe PCIe 3.0 x4 Hot Swap SSD SED 4
4XB7A14059 B6K3 ThinkSystem U.2 CM5-R 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD SED 4
4XB7A14060 B6K4 ThinkSystem U.2 CM5-R 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD SED 4
4XB7A38241 BCAB ThinkSystem U.2 CM5-R 7.68TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD SED 4

Note: NVMe PCIe SSDs support surprise hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 39. M.2 SATA drives
Part number Feature Description Maximum
supported
M.2 SSDs - 6 Gb SATA - Entry (<3 DWPD)
7N47A00129 AUUL ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD 2
7N47A00130 AUUV ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD 2
4XB7A14049 B5S4 ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD 2
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD 2
4XB7A17071 B8HS ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD 2
4XB7A17073 B919 ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD 2

Internal tape drive

The server does not support internal tape drive options.

Optical drive

The server supports the external USB optical drive listed in the following table.

Table 40. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

The drive is based on the Lenovo Slim DVD Burner DB65 drive and supports the following formats: DVD-RAM, DVD-RW, DVD+RW, DVD+R, DVD-R, DVD-ROM, DVD-R DL, CD-RW, CD-R, CD-ROM.

I/O expansion options

The I/O slots for the SD530 nodes are housed in the I/O shuttle in the rear of the enclosure. See the Components and connectors section for the location.

Each SD530 supports internally either:

  • One PCIe 3.0 x16 low-profile adapter slot, or
  • Two PCIe 3.0 x8 low-profile adapter slot

Ordering information is as follows:

Table 41. I/O shuttle ordering information
Part number Feature code Description
CTO only AUY7 ThinkSystem D2 8-slot x8 Shuttle ASM
CTO only AUY8 ThinkSystem D2 4-slot x16 Shuttle

The following figure shows the locations of the slots.

Location of the I/O slots
Figure 10. Location of the PCIe slots at the rear of the Enclosure

A key difference between the two choices, other than the difference in PCIe lane width is which servers must be powered off to perform service on the I/O adapter slots:

  • Adding or replacing an adapter in the x16 slot only requires the one SD530 node to be powered off. The other three servers can remain fully operational.
  • Adding or replacing an adapter in any x8 slot requires that all four SD530 nodes be powered off.

The SD530 also supports the addition of a GPU Tray with two full-length full-height slots. Details about the GPU Tray are in the GPU Tray and GPU adapters section.

SharedIO

SharedIO is a new feature of the SD530 which implements Mellanox Multi-Host technology. With SharedIO, a Mellanox VPI adapter is installed in a slot in one SD530 server and an auxiliary adapter is installed in a slot in second server in the same enclosure. The result is that the two servers share the network connection of the VPI adapter with significant savings both in the cost of the adapters but also the cost of switch ports.

The Mellanox SharedIO Adapter and Auxiliary Card are shown in the following figure.

Lenovo ThinkSystem SharedIO ConnectX-5 Adapter
Figure 11. Lenovo ThinkSystem SharedIO ConnectX-5 Adapter

The feature takes advantage of the design of the D2 Enclosure's x8 shuttle where the slots of two of the SD530 servers are adjacent. The primary and auxiliary adapters are installed in the slots as shown in the following figure.

SharedIO adapters installed in the x8 shuttle
Figure 12. SharedIO adapters installed in the x8 shuttle

Configuration notes:

  • When the SharedIO adapters are installed, the other slots (1A, 2A, 3B, 4B) are reserved and are not available for use with any other adapters.
  • The SharedIO adapters are not supported with the x16 shuttle.

Ordering information for the adapters is in the Network adapters section.

Network adapters

Each SD530 has two dedicated 10Gb ports routed to the 8-port Ethernet I/O Module (EIOM) at the rear of the enclosure as shown in below. The ports are connected to the integrated Intel Ethernet Connection X722 controller. 

Note: The EIOM is optional and can be deselected in the configurator. If the EIOM is not used, then the two 10 GbE ports are not accessible. The EIOM can be added later as a field upgrade.

The ports are assigned as shown in the following figure.

Network port numbering
Figure 13. Network port numbering

The X722 has the following features:

  • Integrated into the Intel PCH chipset
  • Offers VXLAN/NVGRE Hardware Offloads
  • Supports VMDq and SR-IOV for advanced virtualization
  • Supports iWarp RDMA

Note: No support for 10 Mbps or 100 MBps Ethernet connections.

For more information about the X722 controller, see the Lenovo Press product guide:
http://lenovopress.com/lp0654-intel-x722-integrated-controller

Tip: This port numbering is also located on a label affixed to the enclosure. See Figure 4 for the location.

The 10Gb ports have either RJ45 connections or SFP+ cages depending on the EIOM selected. Ordering information is in the following table.

Table 42. EIOM ordering information
Part number Feature code Description
7M17A04001 AUYA ThinkSystem D2 10Gb 8 port EIOM Base T RJ45
7M17A04000 AUY9 ThinkSystem D2 10Gb 8 port EIOM SFP+

The following table lists the supported SharedIO adapters. For details about these adapters see the SharedIO section.

Note: SharedIO adapters are only supported in the x8 shuttle. They are not supported with the x16 shuttle.

Table 43. SharedIO network adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
CTO only B3RZ* Lenovo ThinkSystem SharedIO ConnectX-5 Adapter Shuttle x8: 1-B, 4-A 1
CTO only B3S0* Lenovo ThinkSystem SharedIO ConnectX-5 Auxiliary Card Shuttle x8: 2-B, 3-A 1

* Only available through Lenovo Scalable Infrastructure (LeSI). See the LeSI product guide for details, https://lenovopress.com/lp0900.

The following table lists other supported network adapters. PCIe x16 adapters require the x16 slot so only 1 adapter is supported per node.

Table 44. PCIe network adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter Both slots 2
10 Gb Ethernet RJ45
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter Both slots 2
7ZT7A00496 AUKP ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter Both slots 2
4XC7A08225 B31G ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter Both slots 2
10 Gb Ethernet SFP+
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW Both slots 2
00AG570 AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter Both slots 2
7ZT7A00537 AUKX ThinkSystem X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter Both slots 2
25 Gb Ethernet
4XC7A08228 B21R ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter Both slots 2
7XC7A05523 B0WY ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter Both slots 2
01GR250 AUAJ Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter Both slots 2
7ZT7A00505 AUKS ThinkSystem Broadcom 57412 25GbE SFP28 1-Port PCIe Ethernet Adapter Both slots 2
4XC7A08229 B31C ThinkSystem Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter PCIe x16 slot 1
4XC7A16683 B5XZ ThinkSystem Mellanox Innova-2 ConnectX-5 FPGA 25GbE 2-port Adapter Both slots 2
40 Gb Ethernet
00MM950 ATRN Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter Both slots 2
4XC7A08229 B31C ThinkSystem Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter PCIe x16 slot 1
100 Gb Ethernet
00MM960 ATRP Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter PCIe x16 slot 1
InfiniBand
7XC7A05524 B0WX ThinkSystem Mellanox ConnectX-4 PCIe FDR 1-Port QSFP VPI Adapter Both slots 2
7ZT7A00500 AUVG ThinkSystem Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter Both slots 2
00KH924 ASWQ Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter PCIe x16 slot 1
4C57A14177 B4R9 ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 1-port PCIe VPI Adapter PCIe x16 slot 1
4C57A14178 B4RA ThinkSystem Mellanox ConnectX-6 HDR100/100GbE QSFP56 2-port PCIe VPI Adapter PCIe x16 slot 1
Omni-Path Architecture (OPA)
00WE027 AU0B Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA PCIe x16 slot 1
00WE023 AU0A Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA Both slots 2

For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet

SAS adapters for external storage

The following table lists the SAS HBAs suitable for connectivity to external storage.

Table 45. External SAS HBAs
Part
number
Feature
code
Description Slots
supported
Maximum
supported
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA Both slots 2
7Y37A01091 AUNN ThinkSystem 430-16e SAS/SATA 12Gb HBA Both slots 2

The following table summarizes features of supported adapters.

Table 46. SAS HBA specifications
Feature 430-8e 430-16e
Adapter type HBA HBA
Part number 7Y37A01090 7Y37A01091
Controller chip LSI SAS3408 LSI SAS3416
Host interface PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS
Number of ports 8 16
Port connectors 2x Mini-SAS HD SFF8644 4x Mini-SAS HD SFF8644
Drive interface SAS/SATA SAS/SATA
Drive type HDD/SSD/SED* HDD/SSD/SED*
Hot-swap drives Yes Yes
Maximum devices 512 (planned: 1024) 512 (planned: 1024)
RAID levels None None
JBOD mode Yes Yes
Cache None None
CacheVault cache protection None None
Performance Accelerator (FastPath) No No
SSD Caching (CacheCade Pro 2.0) No No
SED support Yes* Yes*

* SED support of the SAS HBAs is by using software on the server (SED commands are passed through the HBA to the drives).

Fibre Channel host bus adapters

The following table lists Fibre Channel HBAs that are supported by the server.

Table 47. Fibre Channel HBAs
Part
number
Feature
code
Description Slots
supported
Maximum
supported
32 Gb Fibre Channel
4XC7A08250 B5SX ThinkSystem Emulex LPe35000 32Gb 1-port PCIe Fibre Channel Adapter Both slots 2
4XC7A08251 B5SY ThinkSystem Emulex LPe35002 32Gb 2-port PCIe Fibre Channel Adapter Both slots 2
7ZT7A00517 AUNT ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter Both slots 2
7ZT7A00519 AUNV ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter Both slots 2
7ZT7A00516 AUNS ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter Both slots 2
7ZT7A00518 AUNU ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter Both slots 2
16 Gb Fibre Channel
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA Both slots 2
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA Both slots 2
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA Both slots 2
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA Both slots 2
8 Gb Fibre Channel
4XC7A08220* B0WZ ThinkSystem Emulex LPe12000-M8-L PCIe 8Gb 1-Port SFP+ Fibre Channel Adapter Both slots 2
4XC7A08221* B0X0 ThinkSystem Emulex LPe12002-M8-L PCIe 8Gb 2-Port SFP+ Fibre Channel Adapter Both slots 2

* Available in China, Japan, and AP countries only

Flash storage adapters

The following table lists the Flash Storage Adapters supported by the server.

Table 48. Flash Storage Adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Entry NVMe PCIe Adapters - Optimized for read-intensive workloads with an endurance of less than 3 DWPD.
7SD7A05776 B11Z ThinkSystem HHHL Intel P4500 4.0TB Entry NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
7SD7A05775 B120 ThinkSystem HHHL Intel P4500 8.0TB Entry NVMe PCIe3.0 x4 Flash Adapter Both slots 2
Mainstream NVMe PCIe Adapters - Optimized for mixed-intensive application workloads with an endurance of 3-5 DWPD.
4XB7A14075 B8JH ThinkSystem HHHL PM1735 1.6TB Mainstream NVMe PCIe4.0 x4 Flash Adapter Both slots 2
4XB7A14076 B8HW ThinkSystem HHHL PM1735 3.2TB Mainstream NVMe PCIe4.0 x4 Flash Adapter Both slots 2
4XB7A14077 B96M ThinkSystem HHHL PM1735 6.4TB Mainstream NVMe PCIe4.0 x4 Flash Adapter Both slots 2
4XB7A38234 BCGJ ThinkSystem HHHL Kioxia CM5-V 1.6TB Mainstream NVMe PCIe3.0 x4 Flash Adapter Both slots 2
4XB7A38237 BCGK ThinkSystem HHHL Kioxia CM5-V 3.2TB Mainstream NVMe PCIe3.0 x4 Flash Adapter Both slots 2
4XB7A38240 BCGL ThinkSystem HHHL Kioxia CM5-V 6.4TB Mainstream NVMe PCIe3.0 x4 Flash Adapter Both slots 2
4XB7A08520 B32L ThinkSystem HHHL KCM51V 1.6TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
4XB7A08521 B32M ThinkSystem HHHL KCM51V 3.2TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
4XB7A08522 B32N ThinkSystem HHHL KCM51V 6.4TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
7SD7A05769 B11X ThinkSystem HHHL Intel P4600 2.0TB Mainstream NVMe PCIe3.0 x4 Flash Adapter Both slots 2
7SD7A05768 B11Y ThinkSystem HHHL Intel P4600 4.0TB Mainstream NVMe PCIe3.0 x4 Flash Adapter Both slots 2
7N47A00097 AUUP ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
7N47A00098 AUVY ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
Performance NVMe PCIe Adapters - Optimized for write-intensive application workloads with an endurance of 10+ DWPD.
7XB7A05924 AWG9 ThinkSystem HHHL PX04PMC 3.2TB Performance NVMe PCIe 3.0 x4 Flash Adapter Both slots 2
7XB7A05925 AWG8 ThinkSystem HHHL PX04PMC 1.6TB Performance NVMe PCIe 3.0 x4 Flash Adapter Both slots 2

GPU Tray and GPU adapters

The SD530 supports GPU adapters with the addition of SD530 GPU tray. The GPU tray supports one or two double-wide GPUs. The SD530 server and attached GPU tray are show in the following figure. Two of these combined systems can be installed in the enclosure for a total of 4 processors and 4 GPUs in 2U of rack space.

SD530 with GPU Tray attached
Figure 14. SD530 with GPU Tray attached

Ordering information for the GPU tray is as follows.

Table 49. GPU tray
Part number Feature code Description
4M17A09509 B0MU ThinkSystem SD530 GPU Tray

The GPU Tray option includes the necessary PCIe cables to connect the two installed GPUs to the system. The GPU options, listed in the table below, include the necessary auxiliary power cables.

The GPU Tray supports 2 GPUs, once connected to each processor in the SD530. Each GPU is connected via a PCIe 3.0 x16 connect routed from two PCIe 3.0 x8 connectors on the SD530 system board. See Figure 6 for locations of the PCIe connectors.

Table 50. GPU options
Part
number
Feature
code
Description Maximum
supported
7C57A02888 B0LZ ThinkSystem SD530 NVIDIA Tesla P40 2
7X67A00068 B0M1 ThinkSystem SD530 NVIDIA Tesla P100 2
4C57A09498 B1JY ThinkSystem NVIDIA Tesla V100 16GB PCIe Passive GPU 2
4X67A12088 B34S ThinkSystem NVIDIA Tesla V100 32GB PCIe Passive GPU 2
7C57A02891 B0RK ThinkSystem SD530 NVIDIA Tesla M10 2
00KG655 B0M0 ThinkSystem SD530 NVIDIA Tesla M60 2
7C57A02897 B228 ThinkSystem AMD Radeon Instinct MI25 16GB PCIe Passive GPU 2
4C57A09497 B32P ThinkSystem AMD Radeon Pro V340 32GB PCIe Passive GPU 2

For information about these adapters, see the ThinkSystem GPU Summary:
https://lenovopress.com/lp0768-thinksystem-gpu-summary

If the GPU tray is selected then the following configuration rules apply:

  • Two processors are required
  • At most 12 DIMMs can be installed
  • When the Tesla M10 or M60 GPUs are installed, the server system memory must be less than 1 TB
  • Only SATA HDDs and SSDs are supported
  • Only software RAID is supported; the RAID adapter (Feature AUYK) is not supported
  • Only the 4-drive SAS/SATA drive backplane is supported. The 6-drive backplanes (including AnyBay) are not supported.
  • The optional KVM module is supported.
  • OS preload cannot be selected
  • The GPUs installed in the GPU Tray must be identical
  • The enclosure must have 2000W power supplies installed
  • The following enclosure configurations are supported:
    • 2 servers and 2 GPU Trays
    • 1 server and 1 GPU Tray (the other two bays must have 2 fillers installed)
  • The following enclosure configurations are not supported:
    • 2 servers and 1 GPU Tray is not supported
    • 3 servers and 1 GPU Tray is not supported

Power supplies

The D2 Enclosure and Modular Enclosure come standard with two hot-plug power supplies and the power supplies act as a redundant pair ensuring that the enclosure remains powered even if one power supply fails or is disconnected. These AC power supplies are 80 PLUS Platinum certified for energy efficiency.

The following table lists the supported power supply options.

Table 51. Power supply options for the D2 and Modular Enclosures
Part
number
Feature
code
Description 110V AC 220V AC 240V DC
China only
None* AUZ0 ThinkSystem D2 1100W Platinum PSU Yes Yes Yes
None* AUZ1 ThinkSystem D2 1600W Platinum PSU No Yes Yes
None* AUZ2 ThinkSystem D2 2000W Platinum PSU No Yes Yes

* CTO only

Two power supplies are standard and maximum. You cannot mix power supplies.

The 1100W power supply is auto-sensing and supports both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. The 1600 W and 2000 W power supplies only supports 220V AC power. In China only, all power supplies also support 240V DC.

Power supply options do not include a power cord. For models of the D2 Enclosure and Modular Enclosure, the inclusion of a power cords is model dependent. Configure-to-order models can be configured without a power cord if desired.

Use the Lenovo Capacity Planner to determine exactly what power your server needs:
https://datacentersupport.lenovo.com/us/en/products/solutions-and-software/software/lenovo-capacity-planner/solutions/ht504651

Power cords

Line cords and rack power cables with C13 connectors can be ordered as listed in the following table.

110V customers: If you plan to use the 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Table 52. Power cords
Part number Feature code Description
Rack cables - C13 to C14
SL67B08593 BPHZ 0.5m, 10A/100-250V, C13 to C14 Jumper Cord
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08367 B0N5 1.0m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08368 B0N6 1.5m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08365 B0N4 2.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Rack Power Cable
Rack cables - C13 to C14 (Y-cable)
00Y3046 A4VQ 1.345m, 2X C13 to C14 Jumper Cord, Rack Power Cable
00Y3047 A4VR 2.054m, 2X C13 to C14 Jumper Cord, Rack Power Cable
Rack cables - C13 to C20
39Y7938 6204 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable
Rack cables - C13 to C20 (Y-cable)
47C2491 A3SW 1.2m, 16A/100-250V, 2 Short C13s to Short C20 Rack Power Cable
47C2492 A3SX 2.5m, 16A/100-250V, 2 Long C13s to Short C20 Rack Power Cable
47C2493 A3SY 2.8m, 16A/100-250V, 2 Short C13s to Long C20 Rack Power Cable
47C2494 A3SZ 4.1m, 16A/100-250V, 2 Long C13s to Long C20 Rack Power Cable
Line cords
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 - 2P+Gnd (Brazil) Line Cord
39Y7928 6210 2.8m, 220-240V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
81Y2376 6572 4.3m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13(2P+Gnd) (India) Line Cord
81Y2386 6567 4.3m, 10A/240V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/230V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 220-240V, C13 to CEI 23-16 (Italy/Chile) Line Cord
81Y2380 6493 4.3m, 10A/230V, C13 to CEI 23-16 (Italy/Chile) Line Cord
46M2593 A1RE 2.8m, 12A/125V, C13 to JIS C-8303 (Japan) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164 (S Africa) Line Cord
81Y2379 6576 4.3m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord
39Y7925 6219 2.8m, 220-240V, C13 to KETI (S Korea) Line Cord
81Y2385 6494 4.3m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/230V, C13 to SEV 1011-S24507 (Sws) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/240V, C13 to CNS 10917-3 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 60799 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A 125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to 76 CNS 10917-3 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/230V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord
00WH545 6401 2.8m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/120V, C13 to NEMA 5-15P (US) Line Cord

Cooling

The enclosures have 5 hot-swap fans which are used to cool all components. In addition, each power supply has its own integrated fan.

The five system fans have the following specifications:

  • Three 60mm hot-swap fans
  • Two 80mm hot-swap fans

The fans are accessible by simply removing the panel on the top of the enclosure.

Location of hot-swap fans
Figure 15. Location of hot-swap fans

Tip: The 80mm fans are hot-swap but you must first disconnect the cable before removing the fan.

 

Integrated virtualization

The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.

You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/

Systems management

The server contains an integrated service processor, XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. The XCC is based on the Pilot4 XE401 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Local management

The SD530 server optionally supports local console support with the addition of the KVM breakout module. The KVM module is installed in one of the drive bays at the front of the server.

The KVM module is shown in the following figure.

KVM breakout module and console breakout cable
Figure 16. KVM breakout module and console breakout cable

The KVM module provides the following:

  • KVM dongle port for optional console breakout cable, which provides VGA port, DB9 serial port, and two USB 2.0 ports
  • USB 3.0 port
  • Micro USB port for connectivity to the XClarity Controller

The Micro USB port is for local tethered connectivity to a mobile device running the XClarity Mobile app. This connection allows the app to connect to the XClarity Controller and provides additional status information about the server. See the XClarity Mobile section below for information.

Ordering information for module and cable are as follows.

Table 53. KVM breakout module and cable ordering information
Part number Feature code Description
7M17A04002 AUYM ThinkSystem SD530 Front VGA/USB KVM Breakout Module
81Y5286 A1NF Console Breakout Cable

The KVM module can be installed in the field:

  • For servers with the 2x2 SAS/SATA backplane, the KVM module is installed in the upper-right drive bay
  • For servers with either 2x3 backplane, the KVM module is installed in the upper-left drive bay

System status with XClarity Mobile

The XClarity Mobile app includes a tethering function where you can connect your Android or iOS device to the server via USB to see the status of the server.

The steps to connect the mobile device are as follows:

  1. Enable USB Management on the server, by holding down the ID button for 3 seconds (or pressing the dedicated USB management button if one is present)
  2. Connect the mobile device via a USB cable to the server's USB port with the management symbol USB Management symbol
  3. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  4. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

Remote management

The D2 Enclosure (machine type 7X20) includes a System Management Module (SMM), installed in the rear of the enclosure. See Figure 3 for the location of the SMM. The SMM provides remote management via a Gigabit Ethernet port of both the enclosure and the individual servers.

The following figure shows the LEDs and connectors of the SMM.

System management module
Figure 17. System management module

The SMM has the following ports and LEDs:

  • RJ45 for remote management access
  • USB port for service
  • System error LED (yellow)
  • Identification LED (blue)
  • Status LED (green)
  • System power LED (green)

The Modular Enclosure (machine type 7X22) has a dual-port SMM standard instead of the single-port SMM. The dual-port SMM is identical to the single-port SMM except that the dual-port SMM contains two RJ45 Ethernet ports instead of one port and supports daisy-chaining. The D2 Enclosure can be upgraded to the dual-port SMM in the field using the option part number listed in the following table.

Table 54. Part number information for the dual-port SMM (for D2 Enclosure only)
Part number Feature code Description
4M17A09510 AXKS ThinkSystem Dual Ethernet Port SMM

The following figure shows the dual-port SMM on the left and the standard (single-port) SMM on the right.


Figure 18. Dual-port SMM and standard (single-port) SMM

The dual-port SMM provides the ability to daisy-chain the Ethernet management connections thereby reducing the number of ports you need in your management switches and reducing the overall cable density needed for systems management. With this feature you can connect the first SMM to your management network and the SMM in a second enclosure connects to the first SMM. The SMM in the third enclosure can then connect to the SMM in the second enclosure.

Up to 7 enclosures can be connected in a daisy-chain configuration, which means that with 4 servers in each node, a total of 28 servers can be managed remotely via one single Ethernet connection.

Notes:

  • If you are using IEEE 802.1D spanning tree protocol (STP) then at most 6 enclosures can be connected together
  • Do not form a loop with the network cabling. The dual-port SMM at the end of the chain should not be connected back to the switch that is connected to the top of the SMM chain.

For more information, see the Internal cable routing section of the SD530 Setup Guide at:
http://thinksystem.lenovofiles.com/help/topic/7X21/cable_routing_6U_enclosure.html?cp=2_0_5_6_5

SMM functions

The SMM provides the following functions:

  • IPMI and Web interface for remote management of the enclosure
  • Remote connectivity to XCC controllers in each node in the enclosure
  • Node-level reporting and control (for example, node virtual reseat/reset)
  • Enclosure power management
  • Enclosure thermal management
  • Enclosure inventory

The USB service button and USB service port are used to gather service data in the event of an error. Pressing the service button copies First Failure Data Collection (FFDC) data to a USB key installed in the USB service port.

The reset button is used to perform an SMM reset (short press) or to restore the SMM back to factory defaults (press for 4+ seconds).

Supported interfaces

The SMM (both single-port and dual-port versions) can be accessed though a web browser interface and via Intelligent Platform Management Interface (IPMI) 2.0 commands.

The XClarity Controller (XCC) in each node also supports remote management, provided though the following interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SMNP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support

IPMI via the Ethernet port (IPMI over LAN) is supported, however it is disabled by default. For CTO orders you can specify whether you want to the feature enabled or disabled in the factory, using the feature codes listed in the following table.

Table 55. IPMI-over-LAN settings
Part number Feature code Description
CTO only B7XZ Disable IPMI-over-LAN (default)
CTO only B7Y0 Enable IPMI-over-LAN

XClarity Controller upgrades

In addition, a virtual presence (remote control & remote media) capability is also optionally available by upgrading each node's XClarity Controller. The available upgrades are XClarity Controller Advanced Upgrade and XClarity Controller Enterprise Upgrade.

Lenovo XClarity Controller Advanced Upgrade adds the following remote control functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Capturing blue-screen errors
  • International keyboard mapping support
  • LDAP-based authentication
  • Optionally, with the XCC Enterprise license upgrade, mapping ISO and diskette IMG image files as virtual drives that are available for use by the server

Lenovo XClarity Controller Enterprise Upgrade enables the following additional features:

  • Boot Capture
  • Remote mounting of ISO and IMG files
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Power capping
  • License for XClarity Energy Manager

Preconfigured models come with either XClarity Controller Standard, Advanced or Enterprise, depending on the model. See the SD530 models section for details. The following table shows the field upgrades available for preconfigured models.

Table 56. XClarity Controller field upgrades
Part number Feature code Description
4L47A09132 AVUT ThinkSystem XClarity Controller Standard to Advanced Upgrade
(for servers that have XCC Standard)
4L47A09133 AVUU ThinkSystem XClarity Controller Advanced to Enterprise Upgrade
(for servers that have XCC Advanced)

For configure-to-order (CTO) models, you can elect to have one of the following XCC functionality by selecting the appropriate XCC feature codes as listed in the following table:

  • XCC Standard - select neither feature listed in the table
  • XCC Advanced - select feature AVUT
  • XCC Enterprise - select feature AUPW
Table 57. XClarity Controller Upgrades for configure-to-order
Feature code Description
AVUT ThinkSystem XClarity Controller Standard to Advanced Upgrade
AUPW ThinkSystem XClarity Controller Standard to Enterprise Upgrade

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

LXPM provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions. It provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator is an optional software component for the SD530. The software can be downloaded and used at no charge to discover and monitor the SD530 and to manage firmware upgrades.

If software support is required for Lenovo XClarity Administrator, or premium features such as configuration management and operating system deployment are required, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.

The following table lists the Lenovo XClarity software license options.

Table 58. Lenovo XClarity Pro ordering information
Part number Feature code Description
00MT201 1339 Lenovo XClarity Pro, per Managed Endpoint w/1 Yr SW S&S
00MT202 1340 Lenovo XClarity Pro, per Managed Endpoint w/3 Yr SW S&S
00MT203 1341 Lenovo XClarity Pro, per Managed Endpoint w/5 Yr SW S&S
7S0X000HWW SAYV Lenovo XClarity Pro, per Managed Endpoint w/6 Yr SW S&S
7S0X000JWW SAYW Lenovo XClarity Pro, per Managed Endpoint w/7 Yr SW S&S

Lenovo XClarity Administrator offers the following standard features that are available at no charge:

  • Auto-discovery and monitoring of Lenovo systems
  • Firmware updates and compliance enforcement
  • External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
  • Secure connections to managed endpoints
  • NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
  • Integration into existing higher-level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
  • An intuitive, easy-to-use GUI
  • Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources

Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:

  • Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
  • Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning

For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager (LXEM) is a power and temperature management solution for data centers. It is an agent-free, web-based console that enables you to monitor and manage power consumption and temperature in your data center through the management console. It enables server density and data center capacity to be increased through the use of power capping.

LXEM is a licensed product. A single-node LXEM license is included with the XClarity Controller Enterprise upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 59. Lenovo XClarity Energy Manager
Part number Description
4L40E51621 Lenovo XClarity Energy Manager Node License (1 license needed per server)

For more information about XClarity Energy Manager, see the following resources:

Security

The server offers the following security features:

  • Administrator and power-on password
  • Trusted Platform Module (TPM) supporting both TPM 1.2 and TPM 2.0
  • Optional plugin Trusted Cryptographic Module (TCM) or Nationz TPM, available only in China

The plugin modules, available only for China customers, are installed in a dedicated socket on the system board, as shown in Figure 6. Ordering information is shown in the following table.

Table 60. Security features
Part number Feature code Description
None* AVKE ThinkSystem Trusted Cryptographic Module (China customers only)
None* B22N ThinkSystem Nationz Trusted Platform Module v2.0 (China customers only)

* Available configure-to-order or pre-configured models only; Not available as a field upgrade.

Operating system support

The server supports the following operating systems:

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=sd530-7x21

Virtualization support: The onboard SATA ports in the server can be used with virtualization hypervisors, including VMware ESXi, Linux KVM, Xen, and Microsoft Hyper-V, however support is limited to AHCI (non-RAID) mode. RSTe mode is not supported with virtualization hypervisors.

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 61. VMware ESXi preload
Part number Feature code Description
CTO only AXFS VMware ESXi 6.0 U3 (factory installed)
CTO only AXFT VMware ESXi 6.5 U1 (factory installed)
CTO only B3VW VMware ESXi 6.5 U2 (Factory Installed)
CTO only B6U0 VMware ESXi 6.5 U3 (factory installed)
CTO only B3VX VMware ESXi 6.7 (Factory Installed)
CTO only B4XA VMware ESXi 6.7 U1 (Factory Installed)
CTO only B6U1 VMware ESXi 6.7 U2 (factory installed)
CTO only B88T VMware ESXi 6.7 U3 (factory installed)
CTO only BBZG VMware ESXi 7.0 (Factory Installed)
CTO only BE5E VMware ESXi 7.0 U1 (Factory Installed)

Rack installation

The D2 Enclosure and Modular Enclosure can be installed in a 19-inch rack cabinet. A rail kit is included in all models and can be included in configure-to-order models. Also available to order as an option is a cable management arm. Ordering information is in the following table.

Table 62. Rail installation components
Part number Feature code Description
CTO only AUYC ThinkSystem D2 Slide Rail
7XF7A03997 AUYD ThinkSystem D2 CMA (Cable Management Arm)

Supported Lenovo racks are listed in the Rack cabinets section.

Physical and electrical specifications

The SD530 server and the enclosures have the following physical specifications.

D2 Enclosure and Modular Enclosure dimensions and weight:

  • Height: 2U enclosure - 87 mm (3.5 inches)
  • Depth: 892 mm (35.1 inches)
  • Width: 488 mm (19.3 inches)
  • Weight:
    • Minimum configuration (with one minimally configured node): 22.4 kg (49.4 lbs)
    • Maximum configuration (with four fully configured nodes): 55.0 kg (121.2 lbs)

SD530 dimensions and weight:

  • Height: 41 mm (1.7 inches)
  • Depth: 562 mm (22.2 inches)
  • Width: 222 mm (8.8 inches)
  • Weight:
    • Minimum weight: 3.5 kg (7.8 lb)
    • Maximum weight: 7.5 kg (16.6 lb) 

Electrical input for the D2 Enclosure and Modular Enclosure:

  • Models with 2000 W AC power supplies:
    • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 9.9 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.17 kVA
      • Maximum configuration: 2.1 kVA
  • Models with 1600 W AC power supplies:
    • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 7.8 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 1.7 kVA
  • Models with 1100 W AC power supplies:
    • 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 11.9 A
    • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 5.4 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.12 kVA
      • Maximum configuration: 1.2 kVA

240V DC support for China customers only:

  • Models with 2000 W 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 9.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 2.2 kVA
  • Models with 1600 W 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 8.6 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 1.7 kVA
  • Models with 1100 W 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 4.9 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 1.1 kVA

Operating environment

The SD530 complies with ASHRAE class A2 specifications, and depending on the hardware configuration, the SD530 also supports ASHRAE Class A3 or Class A4 specifications.

To comply with ASHRAE Class A3 and Class A4 specifications, the SD530 needs to meet the following hardware configuration requirements:

  • Processor: See the table below for ASHRAE support by processor
  • PCIe adapters: The following PCIe adapters are not supported with ASHRAE A3 and A4 specifications:
    • Mellanox Ethernet adapters with active optical cables
    • Flash Storage Adapters
    • GPU adapters
  • Power supplies: Two power supplies, either 1600W or 2000W. 1100W power supplies are not supported with ASHRAE A3 and A4

Environmental information:

The ThinkSystem SD530 and the enclosures are supported in the following environment:

  • Air temperature:
    • Power on:
      • ASHRAE Class A2: 10°C to 35°C (50°F to 95°F);
        Above 900 m (2,953 ft), de-rated maximum air temperature 1°C / 300m (984 ft)
      • ASHRAE Class A3: 5°C to 40°C (41°F to 104°F)
        Above 900 m (2,953 ft), de-rated maximum air temperature 1°C / 175m (574 ft)
      • ASHRAE Class A4: 5°C to 45°C (41°F to 113°F)
        Above 900 m (2,953 ft), de-rated maximum air temperature 1°C / 125m (410 ft)
    • Power off (removed from shipping container): 5°C to 45°C (41°F to 113°F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Power on:
      • ASHRAE Class A2: 8% to 80%, maximum dew point 21°C (70°F)
      • ASHRAE Class A3: 8% to 85%, maximum dew point 24°C (75°F)
      • ASHRAE Class A4: 8% to 90%, maximum dew point 24°C (75°F)
    • Shipment/storage: 8% to 90%
Table 63. Processor support of ASHRAE standards
Description Supports
ASHRAE A2
Supports
ASHRAE A3 and A4
Intel Xeon Bronze 3104 6C 85W 1.7GHz Processor Yes Yes
Intel Xeon Bronze 3106 8C 85W 1.7GHz Processor Yes Yes
Intel Xeon Silver 4108 8C 85W 1.8GHz Processor Yes Yes
Intel Xeon Silver 4109T 8C 70W 2.0GHz Processor Yes No
Intel Xeon Silver 4110 8C 85W 2.1GHz Processor Yes Yes
Intel Xeon Silver 4112 4C 85W 2.6GHz Processor Yes Yes
Intel Xeon Silver 4114 10C 85W 2.2GHz Processor Yes Yes
Intel Xeon Silver 4114T 10C 85W 2.2GHz Processor Yes No
Intel Xeon Silver 4116 12C 85W 2.1GHz Processor Yes Yes
Intel Xeon Silver 4116T 12C 85W 2.1GHz Processor Yes No
Intel Xeon Gold 5115 10C 85W 2.4GHz Processor Yes Yes
Intel Xeon Gold 5117 14C 105W 2.0GHz Processor Yes No
Intel Xeon Gold 5118 12C 105W 2.3GHz Processor Yes Yes
Intel Xeon Gold 5119T 14C 85W 1.9GHz Processor Yes No
Intel Xeon Gold 5120 14C 105W 2.2GHz Processor Yes Yes
Intel Xeon Gold 5120T 14C 105W 2.2GHz Processor Yes No
Intel Xeon Gold 5122 4C 105W 3.6GHz Processor Yes No
Intel Xeon Gold 6126 12C 125W 2.6GHz Processor Yes No
Intel Xeon Gold 6126T 12C 125W 2.6GHz Processor Yes No
Intel Xeon Gold 6128 6C 115W 3.4GHz Processor Yes No
Intel Xeon Gold 6130 16C 125W 2.1GHz Processor Yes No
Intel Xeon Gold 6130T 16C 125W 2.1GHz Processor Yes No
Intel Xeon Gold 6132 14C 140W 2.6GHz Processor Yes No
Intel Xeon Gold 6134 8C 130W 3.2GHz Processor Yes No
Intel Xeon Gold 6134M 8C 130W 3.2GHz Processor Yes No
Intel Xeon Gold 6136 12C 150W 3.0GHz Processor Yes No
Intel Xeon Gold 6138 20C 125W 2.0GHz Processor Yes No
Intel Xeon Gold 6138T 20C 125W 2.0GHz Processor Yes No
Intel Xeon Gold 6140 18C 140W 2.3GHz Processor Yes No
Intel Xeon Gold 6140M 18C 140W 2.3GHz Processor Yes No
Intel Xeon Gold 6142 16C 150W 2.6GHz Processor Yes No
Intel Xeon Gold 6142M 16C 150W 2.6GHz Processor Yes No
Intel Xeon Gold 6144 8C 150W 3.5GHz Processor Yes No
Intel Xeon Gold 6146 12C 165W 3.2GHz Processor Yes No
Intel Xeon Gold 6148 20C 150W 2.4GHz Processor Yes No
Intel Xeon Gold 6150 18C 165W 2.7GHz Processor Yes No
Intel Xeon Gold 6152 22C 140W 2.1GHz Processor Yes No
Intel Xeon Gold 6154 18C 200W 3.0GHz Processor Yes No
Intel Xeon Platinum 8153 16C 125W 2.0GHz Processor Yes No
Intel Xeon Platinum 8156 4C 105W 3.6GHz Processor Yes No
Intel Xeon Platinum 8158 12C 150W 3.0GHz Processor Yes No
Intel Xeon Platinum 8160 24C 150W 2.1GHz Processor Yes No
Intel Xeon Platinum 8160M 24C 150W 2.1GHz Processor Yes No
Intel Xeon Platinum 8160T 24C 150W 2.1GHz Processor Yes No
Intel Xeon Platinum 8164 26C 150W 2.0GHz Processor Yes No
Intel Xeon Platinum 8168 24C 205W 2.7GHz Processor Yes No
Intel Xeon Platinum 8170 26C 165W 2.1GHz Processor Yes No
Intel Xeon Platinum 8170M 26C 165W 2.1GHz Processor Yes No
Intel Xeon Platinum 8176 28C 165W 2.1GHz Processor Yes No
Intel Xeon Platinum 8176M 28C 165W 2.1GHz Processor Yes No
Intel Xeon Platinum 8180 28C 205W 2.5GHz Processor Yes No
Intel Xeon Platinum 8180M 28C 205W 2.5GHz Processor Yes No

Acoustical noise emissions:

With the maximum configuration of four nodes with two processors installed, full memory installed, full hard disk drives installed, and two 2000W power supplies installed:

  • Operation: 6.8 bels
  • Idle: 6.2 bels

Heat output:

Approximate, based on two 2000W power supplies:

  • Minimum configuration (with one minimally configured node): 604.1 BTU per hour (177 watts)
  • Maximum configuration (with four fully configured nodes): 7564.4 BTU per hour (2610 watts)

Shock and vibration:

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg  - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Warranty and Support

The SD530, D2 Enclosure and Modular Enclosure all have a 3 year warranty.

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:

  • Premier Support

    Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:

    • Direct technician-to-technician access through a dedicated phone line
    • 24x7x365 remote support
    • Single point of contact service
    • End to end case management
    • Third-party collaborative software support
    • Online case tools and live chat support
    • On-demand remote system analysis
  • Warranty Upgrade (Preconfigured Support)

    Services are available to meet the on-site response time targets that match the criticality of your systems.

    • 3, 4, or 5 years of service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select markets). Bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of your data center using state-of-the-art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.

  • Enterprise Server Software Support

    Enterprise Software Support is an additional support service providing customers with software support on Microsoft, Red Hat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spare parts.

Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Services

Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

Note: Some service options may not be available in all markets or regions. For more information, go to https://www.lenovo.com/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Here’s a more in-depth look at what we can do for you:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools-based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation. The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.

Regulatory compliance

The ThinkSystem SD530 server conforms or there are plans for the server to conform to the following international standards:

  • UL/IEC 60950-1
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 6, Class A
  • CSA C22.2 No. 60950-1
  • CISPR 22, Class A
  • Japan VCCI, Class A
  • Taiwan BSMI CNS13438, Class A; CNS14336-1
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, and EN61000-3-2, EN61000-3-3)
  • Korea KN32, Class A, KN35
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • China CELP certificate, HJ 2507-2011
  • UL Green Guard, UL2819
  • Energy Star 2.1

The D2 Enclosure and Modular Enclosure conform or there are plans for the enclosures to conform to the following international standards:

  • UL/IEC 60950-1
  • Canada ICES-003, issue 6, Class A
  • CSA C22.2 No. 60950-1
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • China CCC GB4943.1, GB9254, Class A, and GB17625.1
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • Korea KN32, Class A, KN35
  • Russia, Belorussia and Kazakhstan, EAC: TP TC 004/2011(for Safety); TP TC 020/2011(for EMC).
  • Mexico NOM-019
  • CE Mark (EN55022 Class A, EN60950-1, EN55024, and EN61000-3-2, EN61000-3-3)
  • CISPR 22, Class A
  • TUV-GS (EN60950-1/IEC 60950-1, and EK1-ITB2000)
  • UL Green Guard, UL2819
  • China CELP certificate, HJ 2507-2011

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 64. External drive enclosures
Model Description
4587HC1 Lenovo Storage D1212 Disk Expansion Enclosure (2U enclosure with 12x LFF drive bays)
4587HC2 Lenovo Storage D1224 Disk Expansion Enclosure (2U enclosure with 24x SFF drive bays)
6413HC1 Lenovo Storage D3284 High Density Expansion Enclosure (5U enclosure with 84x LFF drive bays)
7DAHCTO1WW Lenovo ThinkSystem D4390 Direct Attached Storage (4U enclosure with 90x LFF drive bays)

For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:

External storage systems

Lenovo offers the ThinkSystem DE Series and ThinkSystem DM Series external storage systems for high-performance storage. See the DE Series and DM Series product guides for specific controller models, expansion enclosures and configuration options:

External backup units

The following table lists the available external SAS tape backup options.

Tip: Verify the end-to-end support of an IBM tape backup solution through the IBM System Storage Interoperation Center (SSIC): http://www.ibm.com/systems/support/storage/ssic

Table 65. External SAS backup options
Part number Description
External SAS tape backup drives
6160S6E IBM TS2260 Tape Drive Model H6S
6160S7E IBM TS2270 Tape Drive Model H7S
6160S8E IBM TS2280 Tape Drive Model H8S
6160S9E IBM TS2290 Tape Drive Model H9S
External SAS tape backup autoloaders
6171S6R IBM TS2900 Tape Autoloader w/LTO6 HH SAS
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS
6171S9R IBM TS2900 Tape Autoloader w/LTO9 HH SAS
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
SAS backup drives for TS4300 Tape Library
01KP934 LTO 6 HH SAS Drive
01KP937 LTO 7 HH SAS Drive
01KP953 LTO 8 HH SAS Drive
02JH836 LTO 9 HH SAS Drive

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

Top-of-rack Ethernet switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 66. Ethernet LAN switches
Part number Description
1 Gb Ethernet Rack switches
7Y810011WW Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front)
7Z320O11WW Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE)
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
1 Gb Ethernet Campus switches
7Z340011WW Lenovo CE0128TB Switch (3-Year Warranty)
7Z360011WW Lenovo CE0128TB Switch (Limited Lifetime Warranty)
7Z340012WW Lenovo CE0128PB Switch (3-Year Warranty)
7Z360012WW Lenovo CE0128PB Switch (Limited Lifetime Warranty)
7Z350021WW Lenovo CE0152TB Switch (3-Year Warranty)
7Z370021WW Lenovo CE0152TB Switch (Limited Lifetime Warranty)
7Z350022WW Lenovo CE0152PB Switch (3-Year Warranty)
7Z370022WW Lenovo CE0152PB Switch (Limited Lifetime Warranty)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7Z330O11WW Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
7Z210O21WW Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE)
7Z330O21WW Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)
7Z210O11WW Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 67. Uninterruptible power supply units
Part number Description
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and the Asia Pacific market.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 68. Power distribution units
Part
number
Feature
code
Description
ANZ
ASEAN
Brazil
EET
MEA
RUCIS
WE
HTK
INDIA
JAPAN
LA
NA
PRC
0U Basic PDUs
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y
0U Switched and Monitored PDUs
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU N N Y N N N Y N N Y Y Y N
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU N N Y N Y N Y N N Y Y Y N
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU Y Y Y Y Y Y Y Y Y N Y N Y
1U Switched and Monitored PDUs
4PU7A81117 BNDV 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - ETL N N N N N N N N N N N Y N
4PU7A77467 BLC4 1U 18 C19/C13 Switched and Monitored 80A 3P Delta PDU N N N N N N N N N Y N Y N
4PU7A77469 BLC6 1U 12 C19/C13 switched and monitored 60A 3P Delta PDU N N N N N N N N N N N Y N
4PU7A77468 BLC5 1U 12 C19/C13 switched and monitored 32A 3P WYE PDU Y Y Y Y Y Y Y Y Y N Y Y Y
4PU7A81118 BNDW 1U 18 C19/C13 switched and monitored 48A 3P WYE PDU - CE Y Y Y Y Y Y Y Y Y N Y N Y
46M4002 5896 1U 9 C19/3 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4004 5894 1U 12 C13 Switched and Monitored DPI PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4003 5897 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
46M4005 5895 1U 12 C13 Switched and Monitored 60A 3 Phase PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71763NU 6051 Ultra Density Enterprise C19/C13 PDU 60A/208V/3PH N N Y N N N N N N Y Y Y N
71762NX 6091 Ultra Density Enterprise C19/C13 PDU Module Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 6030 DPI C13 Enterprise PDU Plus Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8941 6010 DPI C13 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 6060 DPI C19 Enterprise PDU Module (WW) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8923 6061 DPI Three-phase 60A/208V C19 Enterprise PDU (US) N N Y N N N Y N N N Y Y N
1U Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 6002 DPI Single-phase 30A/120V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8939 6003 DPI Single-phase 30A/208V Front-end PDU (US) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8934 6005 DPI Single-phase 32A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
39Y8940 6004 DPI Single-phase 60A/208V Front-end PDU (US) Y N Y Y Y Y Y N N Y Y Y N
39Y8935 6006 DPI Single-phase 63A/230V Front-end PDU (International) Y Y Y Y Y Y Y Y Y Y Y Y Y
1U NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 5900 DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y
Line cords for 1U PDUs that ship without a line cord
40K9611 6504 4.3m, 32A/380-415V, EPDU/IEC 309 3P+N+G 3ph wye (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9612 6502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9613 6503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G (non-US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9614 6500 4.3m, 30A/208V, EPDU to NEMA L6-30P (US) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9615 6501 4.3m, 60A/208V, EPDU to IEC 309 2P+G (US) Line Cord N N Y N N N Y N N Y Y Y N
40K9617 6505 4.3m, 32A/230V, Souriau UTG Female to AS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y
40K9618 6506 4.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

The following table lists the supported rack cabinets.

Table 69. Supported rack cabinets
Part number Description Supports
enclosure
Maximum
supported
Supports
D2 CMA
Supports
0U PDUs
7D2B0001WW
7D2N0001WW
12U 1200mm Deep Micro Data Center Rack Yes 5 Yes No
7D2C0001WW
7D2P0001WW
18U 1200mm Deep Micro Data Center Rack Yes 8 Yes No
93072PX 25U Static S2 Standard Rack Yes 11 No No
93072RX 25U Standard Rack Yes 11 No No
93074RX 42U Standard Rack Yes 20 No No
93084EX 42U Enterprise Expansion Rack Yes 17 No Yes
93084PX 42U Enterprise Rack Yes 17 No Yes
93604PX 42U 1200mm Deep Dynamic Rack Yes 17 Yes No
93614PX 42U 1200mm Deep Static Rack Yes 17 Yes No
93634EX 42U 1100mm Dynamic Expansion Rack Yes 18 Yes Yes
93634PX 42U 1100mm Dynamic Rack Yes 18 Yes Yes
Withdrawn rack cabinets
201886X* 11U Office Enablement Kit No - - -
93074XX* 42U Standard Rack Extension Yes 20 No No
93604EX* 42U 1200mm Deep Dynamic Expansion Rack Yes 17 Yes No
93614EX* 42U 1200mm Deep Static Expansion Rack Yes 17 Yes No
93624EX* 47U 1200mm Deep Static Expansion Rack No - - -
93624PX* 47U 1200mm Deep Static Rack No - - -
93634AX* PureFlex System 42U Rack No - - -
93634BX* PureFlex System 42U Expansion Rack No - - -
93634CX* PureFlex System 42U Rack No - - -

* Withdrawn from marketing

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp0658-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM switches and consoles

The following table lists the supported KVM consoles.

Table 70. KVM console
Part number Description
Consoles
4XF7A84188 ThinkSystem 18.5" LCD Console (with US English keyboard)
4XF7A73009 ThinkSystem 18.5" LCD console (with US English keyboard)
17238BX 1U 18.5" Standard Console (without keyboard - see the next table)

The following table lists the keyboards supported with the 1U 18.5" Standard Console (now withdrawn).

Note: These keyboards are not supported with the ThinkSystem 18.5" LCD Console.

Table 71. Keyboards for 1U 18.5" Standard Console
Part number Description
7ZB7A05469 ThinkSystem Keyboard w/ Int.Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard with Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2

The following table lists the available KVM switches and the options that are supported with them.

Table 72. KVM switches and options
Part number Description
KVM Console switches
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
Cables for ThinkSystem Digital and Analog KVM Console switches
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
Cables for GCM and LCM Console switches
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option Pack
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region-specific offers, please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/

Related product families

Product families related to this document are the following:

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
AnyBay®
Bootable Media Creator
Flex System
Lenovo Services
RackSwitch
ServerProven®
System x®
ThinkServer®
ThinkSystem®
TopSeller
TruDDR4
UpdateXpress System Packs
XClarity®

The following terms are trademarks of other companies:

Intel®, Intel Optane™, and Xeon® are trademarks of Intel Corporation or its subsidiaries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

Microsoft®, ActiveX®, Hyper-V®, PowerShell, Windows PowerShell®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

Other company, product, or service names may be trademarks or service marks of others.